material

fused silica

Agency

Standard Method 6040D
EN 2005/108/EC
EPA 610,625,8015,8082,8100,8141,8270,OLM04.2 SVOA
EPA TO-13,IP-8,8270,525.2,608.1/608.2,608/8081/OLM04.2 PEST
JMHLW
NIOSH 2530,5503
OSHA 62
meets requirements for USP G27 and G36
suitable for EPA 1613

규정 준수

FDA LIB 4423

파라미터

-60-340 °C temperature (isothermal)
-60-360 °C temperature (programmed)

베타 값

250

df

0.25 μm

기술

GC/MS: suitable
gas chromatography (GC): suitable

길이 × I.D.

30 m × 0.25 mm

기질 활성군

Bonded and highly crosslinked; silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane) phase

응용 분야

agriculture
chemicals and industrial polymers
cleaning products
clinical
cosmetics
environmental
flavors and fragrances
food and beverages
forensics and toxicology
industrial hygiene
life science and biopharma
personal care
petroleum
pharmaceutical (small molecule)

컬럼 유형

capillary non-polar

유사한 제품을 찾으십니까? 방문 제품 비교 안내

유사한 품목 비교

전체 비교 보기

차이점 표시

1 of 4

이 품목
28564-U28482-U28466-U
df

0.25 μm

df

0.18 μm

df

0.25 μm

df

0.10 μm

matrix active group

Bonded and highly crosslinked; silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane) phase

matrix active group

Bonded and highly crosslinked; silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane) phase

matrix active group

Bonded and highly crosslinked; silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane) phase

matrix active group

Bonded and highly crosslinked; silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane) phase

parameter

-60-340 °C temperature (isothermal), -60-360 °C temperature (programmed)

parameter

-60-340 °C temperature (isothermal), -60-360 °C temperature (programmed)

parameter

-60-340 °C temperature (isothermal), -60-360 °C temperature (programmed)

parameter

-60-340 °C temperature (isothermal), -60-360 °C temperature (programmed)

material

fused silica

material

fused silica

material

fused silica

material

fused silica

agency

Standard Method 6040D, EPA 610,625,8015,8082,8100,8141,8270,OLM04.2 SVOA, JMHLW, OSHA 62, suitable for EPA 1613, EN 2005/108/EC, NIOSH 2530,5503, EPA TO-13,IP-8,8270,525.2,608.1/608.2,608/8081/OLM04.2 PEST, meets requirements for USP G27 and G36

agency

Standard Method 6040D, EN 2005/108/EC, EPA 610,625,8015,8082,8100,8141,8270,OLM04.2 SVOA, EPA TO-13,IP-8,8270,525.2,608.1/608.2,608/8081/OLM04.2 PEST, JMHLW, NIOSH 2530,5503, OSHA 62, meets requirements for USP G27 and G36, suitable for EPA 1613

agency

Standard Method 6040D, EN 2005/108/EC, EPA 610,625,8015,8082,8100,8141,8270,OLM04.2 SVOA, EPA TO-13,IP-8,8270,525.2,608.1/608.2,608/8081/OLM04.2 PEST, JMHLW, NIOSH 2530,5503, OSHA 62, meets requirements for USP G27 and G36, suitable for EPA 1613

agency

Standard Method 6040D, EN 2005/108/EC, EPA 610,625,8015,8082,8100,8141,8270,OLM04.2 SVOA, EPA TO-13,IP-8,8270,525.2,608.1/608.2,608/8081/OLM04.2 PEST, JMHLW, NIOSH 2530,5503, OSHA 62, meets requirements for USP G27 and G36, suitable for EPA 1613

application(s)

agriculture
chemicals and industrial polymers
cleaning products
clinical
cosmetics
environmental
flavors and fragrances
food and beverages
forensics and toxicology
industrial hygiene
life science and biopharma
personal care
petroleum
pharmaceutical (small molecule)

application(s)

agriculture
chemicals and industrial polymers
cleaning products
clinical
cosmetics
environmental
flavors and fragrances
food and beverages
forensics and toxicology
industrial hygiene
life science and biopharma
personal care
petroleum
pharmaceutical (small molecule)

application(s)

agriculture
chemicals and industrial polymers
cleaning products
clinical
cosmetics
environmental
flavors and fragrances
food and beverages
forensics and toxicology
industrial hygiene
life science and biopharma
personal care
petroleum
pharmaceutical (small molecule)

application(s)

agriculture
chemicals and industrial polymers
cleaning products
clinical
cosmetics
environmental
flavors and fragrances
food and beverages
forensics and toxicology
industrial hygiene
life science and biopharma
personal care
petroleum
pharmaceutical (small molecule)

일반 설명

Application: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles, pesticides, PCBs, and herbicides) or anywhere a low bleed non-polar column is required.
USP Code: This column meets USP G27 and G36 requirements.
Phase:
  • Bonded and highly crosslinked
  • Silphenylene polymer virtually equivalent in polarity to poly(5% diphenyl/95% dimethyl siloxane)
Temp. Limits:
  • ≤0.32 mm I.D.: -60 °C to 340 °C (isothermal) or 360 °C (programmed)
  • ≥0.53 mm I.D.: -60 °C to 330 °C (isothermal) or 340 °C (programmed)

애플리케이션


  • Determination of propargite, tebuconazole and bromopropylate pesticide residues in Taiwan green jujubes by gas chromatography-tandem mass spectrometry.: This study utilized the SLB-5ms Capillary GC Column to analyze pesticide residues in agricultural produce. The method demonstrated high sensitivity and specificity, highlighting the column′s efficacy in complex sample matrices (Zhang et al., 2014).

  • Characterisation of capillary ionic liquid columns for gas chromatography-mass spectrometry analysis of fatty acid methyl esters.: The research explored the performance of SLB-5ms Capillary GC Columns for the analysis of fatty acid methyl esters. The column exhibited superior resolution and stability, making it a valuable tool for lipid analysis in biochemical applications (Zeng et al., 2013).

기타 정보

We offer a variety of chromatography accessories including analytical syringes

법적 정보

SLB is a registered trademark of Merck KGaA, Darmstadt, Germany

used together

제품 번호
설명
가격

가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Tommy W McGaha et al.
PloS one, 10(3), e0118904-e0118904 (2015-03-19)
The suite of pheromones that promote communal oviposition by Simulium vittatum, a North American black fly species, was identified and characterized using gas chromatography-mass spectrometry, electrophysiological, and behavioral bioassays. Behavioral assays demonstrated that communal oviposition was induced by egg-derived compounds
Chemical Characterization of Three Accessions of Brassica juncea L. Extracts from Different Plant Tissues
Oulad El Majdoub Y, et al.
Molecules (Basel), 25(22), 5421-5421 (2020)
Lorenzo Cucinotta et al.
Journal of chromatography. A, 1655, 462473-462473 (2021-09-01)
The use of IRMS as a GC detector has a history going back decades, however the critical issue of wrong δ13C measurements resulting from impure peaks has been often underestimated. To this regard, multidimensional separation techniques are effective tools to
Sophie Duclos et al.
Proteomics, 11(5), 854-864 (2011-02-01)
The essential roles of the endovacuolar system in health and disease call for the development of new tools allowing a better understanding of the complex molecular machinery involved in endocytic processes. We took advantage of the floating properties of small
Annie Xu Zeng et al.
Analytica chimica acta, 803, 166-173 (2013-11-13)
Due to their distinct chemical properties, the application of ionic liquid (IL) compounds as gas chromatography (GC) stationary phases offer unique GC separation especially in the analysis of geometric and positional fatty acid methyl ester (FAME) isomers. Elution behaviour of

문서

Development and validation of a fatty acid methyl esterification method, using methanolic HCl reagent, for FAME analysis by GC of vegetable oils and fats.

Cannabis testing regulations include analysis of purity, potency, and contaminants. Learn more about analysis of cannabis for pesticides, mycotoxins, and pyrethrins registered in California by LC-MS/MS and GC-MS/MS Using Ascentis® Express Biphenyl and SLB®-5ms Columns

Complete workflow for cannabis flower pesticide testing using LC-MS/MS and GC-MS/MS ensures product safety.

Learn more about how the thermal desorption technique is applied for terpene identification, profiling, odor measurement, industrial hygiene, and environmental emissions.

모두 보기

관련 콘텐츠

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

Complete offer for petrochemical testing including environmental and industrial hygiene monitoring solutions.

Chromatograms

질문

1–8 / 8 질문  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 답변
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      도움이 되었습니까?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 답변
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      도움이 되었습니까?

  3. Would you recommend SLB™-5ms Capillary GC Columns for all applications instead of Equity-5, SPB-5, PTE-5, MDN-5, and MDN-5S?

    1 답변
    1. Yes.

      도움이 되었습니까?

  4. What if my method does not allow me to change to SLB™-5ms Capillary GC Columns?

    1 답변
    1. These methods typically specify a 5-type column (DB-5 or equivalent). The SLB-5ms satisfies that requirement.

      도움이 되었습니까?

  5. What are the benefits of the SLB™-5ms Capillary GC Column over other manufacturers’ -5ms columns?

    1 답변
    1. The SLB-5ms excels in several performance criteria.· Low Bleed. The highly crosslinked silphenylene polymer chemistry reduces column bleed to a very low level, resulting in greater signal-to-noise level, allowing lower detection levels.· Inertness. The proprietary surface deactivation reduces interactions between analytes and the column surface, resulting in sharper peak shapes, allowing lower detection levels.· Durability. With the highest published maximum allowable operating temperature (MAOT) of any -5ms column, SLB-5ms columns are designed for long life.· Consistency. Innovative manufacturing processes result in decreased column variability, ensuring that the next column is as good as the last.

      도움이 되었습니까?

  6. Who uses SLB™-5ms Capillary GC Columns?

    1 답변
    1. Any analyst with the need for a non-polar column. Some applications include boiling point separations, GC-MS analyses of semivolatiles, and GC-ECD analyses of pesticides/PCBs. It is estimated that non-polar columns account for 51% of the worldwide column market.

      도움이 되었습니까?

  7. What is the Department of Transportation shipping information for this product?

    1 답변
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      도움이 되었습니까?

  8. How does the SLB™-5ms Capillary GC Column differ from our other 5-type columns?

    1 답변
    1. Many of our other 5-type columns (Equity-5, SPB-5, PTE-5, MDN-5, and MDN-5S) incorporate a siloxane polymer (backbone comprised of Si and O atoms only, side groups are either methyl or phenyl). The SLB-5ms column incorporates a silphenylene polymer (backbone comprised of Si and O atoms plus some phenyl groups, side groups are either methyl or phenyl).

      도움이 되었습니까?

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.