Polycarbonate Membrane Filter, 0.4 μm Pore Size

greener alternative

Isopore, filter diam. 25 mm, hydrophilic, white

Synonim(y):

Isopore Membrane Filter

Zaloguj się, aby wyświetlić ceny organizacyjne i kontraktowe.

Wybierz wielkość

100 FILTERS

1010,00 zł

1010,00 zł


Dostępne do wysyłki DZISIAJSzczegóły



Informacje o tej pozycji

UNSPSC Code:
40161507
NACRES:
NB.24
eCl@ss:
32031602

Przejdź do

Pomoc techniczna
Potrzebujesz pomocy? Nasz zespół doświadczonych naukowców chętnie Ci pomoże.
Pozwól nam pomóc

Nazwa produktu

Polycarbonate Membrane Filter, 0.4 μm Pore Size, Isopore, filter diam. 25 mm, hydrophilic, white

material

plain filter
polycarbonate membrane
white filter

sterility

non-sterile

feature

hydrophilic

manufacturer/tradename

Isopore
Millipore

sustainability

Greener Alternative Product

parameter

≥50 mL/min-cm2 water flow rate at 10 psi (typical results)
≥7 L/min air flow rate at 10 psi
140 °C max. temp.
18 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi)

diam.

25 mm

filter diam.

25 mm

thickness

10 μm

gravimetric extractables

<1%

color

white

refractive index

n/D 1.6

matrix

Isopore

pore size

0.4 μm pore size
10-20 % porosity

bubble point

≥1.5 bar (22 psi) at 23 °C

greener alternative category

shipped in

ambient

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Porównaj podobne pozycje

Wyświetl pełne porównanie

Pokaż różnice

1 of 4

Ta pozycja
HTTP01300HTTP03700HTTP09030
manufacturer/tradename

Isopore, Millipore

manufacturer/tradename

Isopore, Millipore

manufacturer/tradename

Isopore, Millipore

manufacturer/tradename

Isopore, Millipore

pore size

0.4 μm pore size, 10-20 % porosity

pore size

0.4 μm pore size, 10-20 % porosity

pore size

0.4 μm pore size, 10-20 % porosity

pore size

0.4 μm pore size, 10-20 % porosity

parameter

≥50 mL/min-cm2 water flow rate at 10 psi (typical results), 140 °C max. temp., ≥7 L/min air flow rate at 10 psi, 18 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi)

parameter

≥50 mL/min-cm2 water flow rate at 10 psi (typical results), ≥7 L/min air flow rate at 10 psi, 140 °C max. temp., 18 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi)

parameter

≥50 mL/min-cm2 water flow rate at 10 psi (typical results), ≥7 L/min air flow rate at 10 psi, 140 °C max. temp., 18 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi)

parameter

≥50 mL/min-cm2 water flow rate at 10 psi (typical results), ≥7 L/min air flow rate at 10 psi, 140 °C max. temp., 18 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi)

material

plain filter, white filter, polycarbonate membrane

material

plain filter, polycarbonate membrane, white filter

material

plain filter, polycarbonate membrane, white filter

material

plain filter, polycarbonate membrane, white filter

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

Application

  • Absorbable organic halides (AOX)
  • Particle monitoring
  • Air monitoring
  • Microplastics analysis
  • Microplastics analysis grade water

Isopore membrane filter has been used:

  • for culturing organotypic brain slices[1]
  • organotypic vibrosections[2]
  • as a working electrode for the synthesis of Helical nanomotors.[3]

Disclaimer

Possible reduction in flow rates may occur after autoclaving.

Features and Benefits

  • Membrane structure retains particles on the surface, simplifying counting and analysis
  • Isopore membranes do not stain, resulting in low background interference
  • Non-hygroscopic, allowing for rapid drying and reduced sample analysis time
  • Translucent material does not require clearing for transmitted light microscopy; also available in brown variety

General description

The Isopore membrane is a polycarbonate, track-etched screen filter recommended for all analyses in which the sample is viewed on the surface of the membrane. Isopore membrane offers many advantages for the analysis of airborne contaminants and other particles using optical or electron microscopy. The Isopore membrane is composed of polycarbonate film, which has a smooth, glass-like surface for clearer sample observation. The unique manufacturing process of the membrane ensures a precise pore diameter and a consistent pore size for accurate separation of samples by size. Matched-weight filters are not usually required because of low, constant tar and ash weights.
We are committed to bringing you Greener Alternative Products, which have been re-engineered to enable more sustainable research solutions. The inner & outer boxes containing the membrane discs are made from bio-circular material allocated using the ISCC mass balance approach. Click here for more information.

Legal Information

ISOPORE is a trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.

Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Jinxing Li et al.
Advanced materials (Deerfield Beach, Fla.), 30(2) (2017-12-02)
One emerging and exciting topic in robotics research is the design of micro-/nanoscale robots for biomedical operations. Unlike industrial robots that are developed primarily to automate routine and dangerous tasks, biomedical nanorobots are designed for complex, physiologically relevant environments, and
Nina Daschil et al.
Brain research, 1581, 1-11 (2014-07-20)
Neurodegeneration of cholinergic and dopaminergic neurons is a major hallmark in Alzheimer's or Parkinson's disease, respectively. A dysregulation in calcium homeostasis may be part of this process and counteracting calcium influx may have neuroprotective properties in both diseases. Therefore, we
Buket Ucar et al.
Experimental brain research, 238(11), 2521-2529 (2020-08-31)
Vessel damage is a general pathological process in many neurodegenerative disorders, as well as spinal cord injury, stroke, or trauma. Biomaterials can present novel tools to repair and regenerate damaged vessels. The aim of the present study is to test

Questions

Reviews

No rating value

Active Filters

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej