The Isopore membranes can be sterilized by autoclaving (121 °C at 1 bar), EtO exposure, or gamma irradiation. It's important to note that autoclaving may lead to a reduction in flow rates.
Wybierz wielkość
| Gabaryty przesyłki | SKU | Dostępność | Cena netto |
|---|---|---|---|
| 100 filters | Dostępne do wysyłki DZISIAJzKuehne + Nagel Sp. z o.o. | 1080,00 zł |
Informacje o tej pozycji
1080,00 zł
Dostępne do wysyłki DZISIAJSzczegóły
Quality Level
material
plain filter, polycarbonate membrane, white filter
sterility
non-sterile
feature
hydrophilic
manufacturer/tradename
Isopore™, Millipore
sustainability
Greener Alternative Product
parameter
≥50 mL/min-cm2 water flow rate at 10 psi (typical results), ≥7 L/min air flow rate at 10 psi, 140 °C max. temp., 18 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi)
diam.
47 mm
filter diam.
47 mm
thickness
10 μm
Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów
1 of 1
Ta pozycja | |||
|---|---|---|---|
| material plain filter, white filter, polycarbonate membrane | material plain filter, polycarbonate membrane, white filter | material plain filter, polycarbonate membrane, white filter | material plain filter, polycarbonate membrane, white filter |
| pore size 0.4 μm pore size, 10-20 % porosity | pore size 11.3 % porosity, 3.0 μm pore size | pore size 0.22 μm pore size, 13.8 % porosity | pore size 0.8 μm pore size, 5-20 % porosity |
| manufacturer/tradename Isopore™, Millipore | manufacturer/tradename Isopore™, Millipore | manufacturer/tradename Isopore™, Millipore | manufacturer/tradename Isopore™, Millipore |
| diam. 47 mm | diam. 25 mm | diam. 47 mm | diam. 25 mm |
| parameter ≥50 mL/min-cm2 water flow rate at 10 psi (typical results), 140 °C max. temp., ≥7 L/min air flow rate at 10 psi, 18 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi) | parameter 0.868 L/min-cm2-psi air flow rate, 140 °C max. temp., 3628 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi), ~475 mL/min-cm2 water flow rate at 10 psi (typical results) | parameter 0.007 L/min-cm2-psi air flow rate, 140 °C max. temp., 3.36 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi), ~16 mL/min-cm2 water flow rate at 10 psi (typical results) | parameter 125 mL/min-cm2-psi water flow rate (maximum flow rate per 1.0 psi), 140 °C max. temp., 4.08 L/min-cm2-psi air flow rate, ~85 mL/min-cm2 water flow rate at 10 psi (typical results) |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
General description
Application
- Absorbable organic halides (AOX)
- Particle monitoring
- Air monitoring
- Microplastics analysis
- Microplastics analysis grade water
Features and Benefits
- Isopore™ membranes display low background interference.
- Surface particle retention enabling simplified counting and analysis.
- Non-hygroscopic favors rapid drying and easy sample analysis.
- Translucent material; available in brown variety as well.
Legal Information
Disclaimer
related product
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Numer pozycji handlu globalnego
| SKU | NUMER GTIN |
|---|---|
| HTTP04700 | 04053252366284 |
-
Is it possible to autoclave HTTP04700?
1 answer-
Helpful?
-
Active Filters
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej