Przejdź do zawartości
Merck

P3C010C05

Pellicon® 3 Cassette with Ultracel® Membrane

filtration area 0.57 m2, NMWCO 10 kDa

Synonim(y):

Pellicon® 3 Cassette with Ultracel 10 kDa Membrane, C screen, 0.57 m2

Zaloguj się aby wyświetlić ceny organizacyjne i kontraktowe

Wybierz wielkość

1 EA

17 690,00 zł

17 690,00 zł


Przewidywany termin wysyłki02 marca 2026Szczegóły



Informacje o tej pozycji

Kod UNSPSC:
41104903
eCl@ss:
32031602

Przejdź do

Pomoc techniczna
Potrzebujesz pomocy? Nasz zespół doświadczonych naukowców chętnie Ci pomoże.
Pozwól nam pomóc

Materiały

TPE seal
composite regenerated cellulose (CRC)
polypropylene screen
stainless steel cap (for end; polypropylene-encapsulated)

Poziom jakości

Właściwości

holdup volume 85 mL (in feed channel)

producent / nazwa handlowa

Pellicon®

Parametry

30 psi max. reverse press. exposure at 25 °C (for 24 hours)
4-6 L/min-m2 recirculation rate
40 psi max. transmembrane pressure at 4-50 °C
6.9 bar max. inlet pressure (100 psi)
80 psi max. transmembrane pressure at 4-40 °C

metody

analytical sample preparation: suitable
buffer exchange: suitable
protein purification: suitable (concentration)

Wysokość

2.4 cm (0.93 in.)

Długość

20.6 cm (8.1 in.)

Szerokość

17.8 cm (7 in.)

powierzchnia filtracyjna

0.57 m2

powierzchnia membrany

0.57 m2

substancje ekstrahujące się grawimetrycznie

≤1500 mg/m2

Matryca

Ultracel® (Membrane)

wielkość porów

10 kDa NMWCO

pH

2-13

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Porównaj podobne pozycje

Wyświetl pełne porównanie

Pokaż różnice

1 of 4

Ta pozycja
P3C005C05P3C030D05P3C010C01
pore size

10 kDa NMWCO

pore size

5 kDa NMWCO

pore size

30 kDa NMWCO

pore size

10 kDa NMWCO

filtration area

0.57 m2

filtration area

0.57 m2

filtration area

0.57 m2

filtration area

0.11 m2

technique(s)

analytical sample preparation: suitable, protein purification: suitable (concentration), buffer exchange: suitable

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

material

TPE seal, polypropylene screen, composite regenerated cellulose (CRC) , stainless steel cap (for end; polypropylene-encapsulated)

material

TPE seal, composite regenerated cellulose (CRC) , polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated)

material

TPE seal, composite regenerated cellulose (CRC) , polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated)

material

TPE seal, composite regenerated cellulose (CRC) , polypropylene cap (for end), polypropylene screen

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 40 psi max. transmembrane pressure at 4-50 °C, 80 psi max. transmembrane pressure at 4-40 °C

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

Opis ogólny

Pellicon® 3 filtration devices are advanced, high-performance cassettes ideal for today’s higher titer therapeutic antibodies as well as the more demanding filtration processes that require higher operating pressures, temperatures and caustic cleaning regimes.

The Pellicon® 3 Cassette with Ultracel® Membrane is designed for the filtration of therapeutic proteins (such as monoclonal antibodies) and recombinant and non-recombinant proteins.

This P3C010C05 Pellicon® 3 ultrafiltration device features a pore size of 10 kDa NMWCO, a filtration area of 0.57 m2, a PLCGC membrane, and dimensions measuring 2.3 cm (H) x 5.6 cm (W) x 20.6 cm (L).

Cechy i korzyści

  • Rugged & reliable – ideally suited for today′s more demanding filtration processes
  • High performance – produces excellent resolution, yields and back-pressure resistance
  • Optimum product recovery – thanks to proven membrane technology
  • Void-free technology – leading-edge membranes resolve virtually any separation challenge
  • Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
  • Automated manufacturing – delivers unbeatable performance, consistency and reliability
  • Easy installation & care – simple to install and maintain

Komentarz do analizy

Gravimetric Extractables: after 24 hours in water at controlled room temperature

Inne uwagi

These products are manufactured in a facility which adheres to Good Manufacturing Practices.

Informacje prawne

Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.

Kod klasy składowania

10 - Combustible liquids

Klasa zagrożenia wodnego (WGK)

WGK 1


Zgodność z GMP dzięki programowi Emprove®

Przyspiesz kwalifikacje, zachowaj zgodność i oszczędzaj czas dzięki Emprove® Dossiers.

Pobierz Dossiers

Uwaga: zostaniesz przeniesiony do EmproveSuite.com. Twoja nazwa użytkownika i hasło są niezależne od SigmaAldrich.com i mogą się różnić.

Zarejestruj się za darmo i uzyskaj dostęp do Emprove® Dossiers w ciągu kilku minut. Uaktualnij swój plan subskrypcji, aby odblokować zaawansowaną i spersonalizowaną zawartość w Emprove® Suite.

Nie znalazłeś tego, czego szukasz? Odwiedź stronę pomocy programu Emprove®..

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Questions

Reviews

No rating value

Active Filters

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej