Przejdź do zawartości
Merck
  • Environmental friendly method for urban wastewater monitoring of micropollutants defined in the Directive 2013/39/EU and Decision 2015/495/EU.

Environmental friendly method for urban wastewater monitoring of micropollutants defined in the Directive 2013/39/EU and Decision 2015/495/EU.

Journal of chromatography. A (2015-10-04)
Ana R Ribeiro, Marta Pedrosa, Nuno F F Moreira, Manuel F R Pereira, Adrián M T Silva
ABSTRAKT

The fate and removal of organic micropollutants in the environment is a demanding issue evidenced by the recent European policy. This work presents an analytical method for the trace quantification of 37 micropollutants including Priority Substances (Directive 2013/39/EU), substances of the recent watch list (Decision 2015/495/EU) and contaminants of emerging concern: pesticides, multi-class pharmaceuticals and a metabolite, estrogens and one industrial compound. The analytical method was based on solid phase extraction (SPE) followed by ultra-high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS), using eco-friendly solvents (ethanol and ultrapure water) both in the SPE and UHPLC, according to green analytical chemistry principles. Briefly, Oasis(®) HLB cartridges were used to preconcentrate 100mL of water samples and the reconstituted extracts were analyzed with a Kinetex™ column under reversed mode, the linear ranges extended to 200ngL(-1) (R(2)>0.99) for all the analytes. The method detection limits were between 0.04 and 2.26ngL(-1) and the method quantification limits were between 0.13 and 6.85ngL(-1). The identity of the compounds was confirmed using two MS/MS transitions and its ion ratios, according to Decision 2002/657/EC. The validated method was applied to wastewater treatment plant samples, assessing the concentration of micropollutants after secondary biological and tertiary UV treatments. Lab-scale photolysis and ozonation experiments were also performed with the secondary effluents, with ozonation showing the best performance for the removal of most of the determined micropollutants.

MATERIAŁY
Numer produktu
Marka
Opis produktu

Sigma-Aldrich
Simvastatin, ≥97% (HPLC), solid
Sigma-Aldrich
(S)-(+)-6-Methoxy-α-methyl-2-naphthaleneacetic acid, 98%
Sigma-Aldrich
(S)-(+)-Clopidogrel hydrogensulfate, ≥98% (HPLC)
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Citalopram hydrobromide, ≥98% (HPLC)
Sigma-Aldrich
(±)-Propranolol hydrochloride, ≥99% (TLC), powder
Sigma-Aldrich
Naproxen, meets USP testing specifications
Sigma-Aldrich
Fluticasone propionate, ≥98% (HPLC), powder
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Supelco
Atrazine, analytical standard
Sigma-Aldrich
Ammonium hydroxide solution, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Ammonium hydroxide solution, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
Formic acid, ACS reagent, ≥88%
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Clarithromycin, 96.0-102.0% (HPLC)
Sigma-Aldrich
Pentachlorophenol, 97%
Sigma-Aldrich
Trimethoprim, ≥99.0% (HPLC)
Sigma-Aldrich
Sulfuric acid, 99.999%
Sigma-Aldrich
Ammonium acetate, 99.999% trace metals basis
Sigma-Aldrich
Ibuprofen, ≥98% (GC)
Sigma-Aldrich
Carbamazepine, meets USP testing specifications
Sigma-Aldrich
Diuron, ≥98%