Please see the full dimensions below:
Number of wells - 96
Well shape - round
Well bottom - flat
Plate length - 127.9 mm
Plate width - 85.6 mm
Plate Height - 14.6 mm
Column offset, left edge to A1 center - 14.4 mm
Row offset, top edge to A1 center - 11.4 mm
Well spacing – 9 mm
Well diameter - 6.2 mm
Well height - 12.1 mm
材料
Durapore PVDF membrane
clear acrylic plate
flat bottom wells
品質等級
描述
Non-sterile, clear 96-well filter plate with 0.45 um pore size Hydrophobic PVDF membrane for Avidin-biotin Linkages, DNA-binding Proteins, Protein Binding & PAMPA. Comes in a pack of 50.
無菌
non-sterile
產品線
MultiScreen®
用途
Manual
特點
hydrophobic
lid
包裝
pkg of 50 plates
製造商/商標名
MultiScreen®
參數
50-250 μL sample volume (per well)
技術
cell based assay: suitable
dot blot: suitable
parallel artificial membrane permeation assay (PAMPA): suitable
過濾面積
0.3 cm2
板尺寸
96 well
孔最大容積
300 μL
有效容積
50-250 μL
基質
Immobilon®-P
孔徑
0.45 μm pore size
結合類型
high binding surface
相容性
manifold only
運輸包裝
ambient
1 of 4
本產品 | MSIPN4B10 | MSHVN4B | MSIPS4W10 |
|---|---|---|---|
| binding type high binding surface | binding type high binding surface | binding type low binding surface | binding type high binding surface |
| manufacturer/tradename MultiScreen® | manufacturer/tradename MultiScreen® | manufacturer/tradename MultiScreen® | manufacturer/tradename MultiScreen® |
| pore size 0.45 μm pore size | pore size 0.45 μm pore size | pore size 0.45 μm pore size | pore size 0.45 μm pore size |
| material PVDF membrane (hydrophobic), flat bottom wells, acrylic | material Barex® , PVDF membrane (hydrophobic), flat bottom wells, titanium dioxide | material Barex® , PVDF membrane (hydrophilic), flat bottom wells, titanium dioxide | material PVDF membrane (hydrophobic), acrylic , flat bottom wells |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility sterile |
| feature hydrophobic, lid | feature hydrophobic, lid | feature hydrophilic, lid | feature hydrophobic, lid |
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。
文章
Combining solubility & PAMPA assays streamlines drug permeability testing.
This is a white paper on the Evaluation of the reproducibility of Parallel Artificial Membrane Permeation Assays (PAMPA) using MultiScreen® Filter Plates.
This is a protocol for a Membrane Integrity test for Lipid-PAMPA Artificial Membranes
條款
Guidelines for various bioassays on the MultiScreen system, which makes it possible to carry out an assay from sample incubation to scintillation counting in a 96-well plate.
Assays that predict passive absorption of orally administered drugs have become increasingly important in the drug discovery process. As previously described by Faller and Kansy such assays provide rapid, low cost and automation friendly methods to measure a compound’s passive permeability.
預測口服藥物被動吸收的實驗在藥物發現過程中已變得越來越重要。正如 Faller 和 Kansy 之前所描述的,此類檢測提供了快速、低成本和自動化的方法來測量化合物的被動滲透性。
相關內容
MultiScreen Immobilon-P Filtration Plates
-
I am looking for the geometry data of the plate. Respectively the height, width, and length of the full plate plus the the diameter and depth of one well.
1 answer-
Helpful?
-
-
Could you please explain the meaning of the terms "donor," "acceptor," "receiver," and "collection" in relation to MAIPN4550 and MAIPN4510 filter plates?
1 answer-
The donor plate is also known as the filter plate, while the acceptor plate can be referred to as the acceptor, receiver, or collection plate. For detailed information on the PAMPA assay, you can refer to the provided link. Additionally, a datasheet is available that reviews some of the donor and acceptor plates. The donor plates include MAIPN4550 and MAIPNTR10. An alternative donor plate option is S2EM004M99, which is a 'MA' classic designed plate. It is important to note that any plate starting with 'MS---' in the catalog number cannot be used.
As for the acceptor plates, several options are available, such as MSSACCEPT0R, MATRNPS50, and MSCPNUV40.
Moreover, tech notes for the automation of PAMPA-Lipid on the Sciclone ALH 3000 workstation and the automation of PAMPA-HDM using a MultiScreen® Filter Plate on a Beckman Biomek® FX Workstation are also available. An article titled "Evaluation of the reproducibility of Parallel Artificial Membrane Permeation Assays (PAMPA)" provides further insights into the topic.
Helpful?
-
Active Filters
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務