品質等級
物種活性
mouse
製造商/商標名
Milliplex®
assay range
accuracy: 82-102%
sensitivity: 0.26-11.14 pg/mL
standard curve range: 0.10-400 pg/mL
(IL-4)
standard curve range: 0.49-2,000 pg/mL
(IFNγ)
standard curve range: 0.49-2,000 pg/mL
(IL-17A)
standard curve range: 0.49-2,000 pg/mL
(IL-7)
standard curve range: 0.49-2,000 pg/mL
(TNFα)
standard curve range: 0.73-3,000 pg/mL
(KC/GROα/CXCL1)
standard curve range: 0.98-4,000 pg/mL
(IL-2)
standard curve range: 0.98-4,000 pg/mL
(IL-5)
standard curve range: 0.98-4,000 pg/mL
(IL-6)
standard curve range: 1.34-5,500 pg/mL
(IL-10)
standard curve range: 2.93-12,000 pg/mL
(IL-12 (p70))
standard curve range: 3.17-13,000 pg/mL
(MCP-1/CCL2)
standard curve range: 3.42-14,000 pg/mL
(IL-13)
standard curve range: 3.91-16,000 pg/mL
(IL-1α)
standard curve range: 3.91-16,000 pg/mL
(IL-1β)
standard curve range: 6.1-25,000 pg/mL
(GM-CSF)
standard curve range: 7.32-30,000 pg/mL
(MIP-2/CXCL2)
standard curve range: 9.77-40,000 pg/mL
(LIX)
inter-assay cv: <15%
intra-assay cv: <10%
技術
multiplexing: suitable
相容性
configured for Premixed
檢測方法
fluorometric (Luminex xMAP)
運輸包裝
ambient
1 of 4
本產品 | MHSTCMAG-70K | HSTCMAG-28SK | MHSTCMAG-70KPXBK |
|---|---|---|---|
| species reactivity mouse | species reactivity mouse | species reactivity human | species reactivity mouse |
| assay range accuracy: 82-102%, standard curve range: 0.10-400 pg/mL | assay range accuracy: 82-102%, sensitivity: 0.26-11.14 pg/mL, standard curve range: 0.10-400 pg/mL | assay range accuracy: 98-107%, sensitivity: 0.11-8.17 pg/mL | assay range accuracy: 82-102%, sensitivity: 0.26-11.14 pg/mL, standard curve range: 0.10-400 pg/mL |
| manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® |
| Quality Level 200 | Quality Level 200 | Quality Level 200 | Quality Level 200 |
| compatibility configured for Premixed | compatibility - | compatibility - | compatibility configured for Premixed |
| shipped in ambient | shipped in ambient | shipped in wet ice | shipped in ambient |
一般說明
Low levels of inflammation are involved in many clinical and sub-clinical disease states, such as autoimmune disease, cardiovascular disease, diabetes, neurological disorders, and cancer. Measuring picogram levels of cytokines, therefore, is critical for understanding the pathogenesis of these diseases.
Panel Type: Cytokines/Chemokines
應用
- Analytes: GM-CSF, IFNγ, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-10, IL-12 (p70), IL-13, IL-17A, KC/CXCL1, LIX, MCP-1, MIP-2, TNF-α
- Recommended Sample type: serum, plasma, tissue culture or other media
- Recommended Sample dilution: neat or 1:2 diluted serum or plasma
- Assay Run Time: Overnight
- Research Category: Inflammation & Immunology
- Research Subcategory: Immune Response Metabolic Disorders Chronic Inflammatory Disease Cardiovascular Disease
生化/生理作用
There is no detectable cross-reactivity within the panel.
準備報告
其他說明
法律資訊
免責聲明
訊號詞
Danger
危險分類
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
標靶器官
Respiratory Tract
儲存類別代碼
10 - Combustible liquids
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。
Active Filters
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務