跳轉至內容
Merck

PFHYS0616

Millicell® HY Multilayer Culture Flask

T-600, 3 layer, 120-180 mL, sterile, vented cap, Tissue Culture (TC)-treated surface

同義詞:

High Yield Culture Flask, Millicell HY Flask T-600 Cell Culture Flask, cell culture, cell culture flask, multi-layer flask, tissue culture

登入 查看組織和合約定價

選擇尺寸

暫時無法取得訂價和供貨情況

關於此項目

分類程式碼代碼:
41104923
eCl@ss:
32011202
NACRES:
NB.22

跳轉至

技術服務
需要援助?我們經驗豐富的科學家團隊隨時樂意為您提供支援。
讓我們為您提供幫助

材料

angled neck high-density polyethylene cap (vented)
polystyrene flask

品質等級

無菌

sterile; γ-irradiated

特點

3 layer

包裝

pack of 16

製造商/商標名

Millicell®

參數

45 °C max. temp.

技術

cell culture | mammalian: suitable

高度

32 mm , excluding cap
51 mm , including cap

長度

22.2 cm

寬度

12 cm

表面積

600 cm2

有效容積

120-180 mL

結合類型

Tissue Culture (TC)-treated surface

運輸包裝

ambient

比較類似項目

查看完整比較

Show Differences

1 of 4

本產品
PFHYS1008CLS430641CLS430824
manufacturer/tradename

Millicell®

manufacturer/tradename

Millicell®

manufacturer/tradename

Corning 430641

manufacturer/tradename

Corning 430824

material

angled neck high-density polyethylene cap (vented), polystyrene flask

material

high-density polyethylene cap, polystyrene flask

material

canted neck , cap (vented), polystyrene , rectangular flask

material

canted neck , cap (phenolic-style), phenolic cap, polystyrene , rectangular bottom flask, rectangular flask

binding type

Tissue Culture (TC)-treated surface

binding type

Tissue Culture (TC)-treated surface

binding type

-

binding type

Tissue Culture (TC)-treated surface

feature

3 layer

feature

5 layer

feature

graduations

feature

cap, graduations

surface area

600 cm2

surface area

1000 cm2

surface area

75 cm2

surface area

150 cm2

packaging

pack of 16

packaging

pack of 8

packaging

case of 100

packaging

case of 50

一般說明

The Millicell® HY Flask is designed to enhance cell culture efficiency across various research applications, including cell banking, cell-based assays, and virus production.

特點和優勢

  • Multilayer Design: Available in 3- and 5-layer configurations, providing a larger surface area for cell growth while maintaining a compact footprint similar to traditional T-flasks
  • Enhanced Accessibility: Designed for better pipette access, accommodating larger volume pipettes (up to 25 mL)
  • Increased Efficiency: Cultivate more cells in the same space, maximizing research output
  • Space Optimization: Achieves significant space savings compared to other multilayer flasks on the market

準備報告

  1. To seed cells, fill the Millicell HY T-600 Flask with the desired growth media.
  2. Add desired number of cells to achieve typical seeding density.
  3. Mix the cells and media by raising the end of the flask and pipetting the solution up and down several times until a homogeneous suspension is achieved. Note: Failure to adequately mix cells into a homogeneous suspension may result in an uneven distribution of cells across the layers of the Millicell HY Flask.
  4. Briefly lay the flask on its side to equilibrate the liquid volume equally among the layers of the flask.
  5. Tilt the flask on its end to partition the liquid volume for each layer of the flask.
  6. Lay the flask down to spread the cell suspension evenly across the entire surface of each layer.
  7. Depending on the volume it may be necessary to rock the flask on all four corners to ensure that the entire surface wets. Note: If the liquid volume on any of the layers changes during the wetting procedure (e.g., spilling of liquid from top layer to lower layers), repeat steps 4–6 to ensure even distribution of liquid among all layers.
  8. Return the flask to a vertical position when transporting to the incubator. Lay the flask flat in the incubator (as in step 6) and culture cells under appropriate conditions.
  9. If media exchange is required, either aspirate or pour the media from the Millicell HY T-600 Flask. Note: Due to the larger surface area of the Millicell Flasks, it may be necessary to let the flask stand on its side for several minutes following each aspiration so that all residual liquid pools to a common point, allowing for a second aspiration to completely remove the remaining liquid.
  10. Add appropriate volume of fresh media, and repeat steps 4–8.
  11. To harvest cells, remove media as in step 9.
  12. Add desired amount of appropriate wash solution (e.g., PBS or 0.02% EDTA) to the flask and repeat steps 4–7.
  13. Remove wash solution as in step 9.
  14. Add desired amount of dissociation enzyme (e.g., 0.25% trypsin/EDTA or equivalent) according to preferred protocol, repeat steps 4–8, and incubate. Volume of dissociation enzyme required per cm2 does not need to be altered from T-flask protocol. Note: Ensure that all cells have completely dissociated from the surface of the flask via observation under microscope. Failure to allow complete dissociation of cells from culture surface (such that all cells are freely floating) may result in reduced cell yields.
  15. If using trypsin, add desired volume of inactivating solution, such as serum-containing media.
  16. Collect cells either by aspirating or pouring, as in step 9.

法律資訊

Millicell is a registered trademark of Merck KGaA, Darmstadt, Germany

分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

相關內容

Monitor your cell cultures with ease with the Millicell® DCI Digital Cell Imager. From confluency to cell count and morphology, the Millicell® DCI automates cell culture measurements for quicker, more consistent culturing.

使用 Millicell® DCI 數位細胞成像儀輕鬆監控您的細胞培養。Millicell® DCI 可自動進行細胞培養測量,從匯合度到細胞數量和形態,讓培養更快速、更一致。

Millicell® HY Multilayer Culture Flasks Enable Higher Cell Recovery and Space Savings Compared to Other Multilayer Flasks

Successful delivery of nucleic acids and protein in eukaryotic cells requires a transfection protocol that maximizes transfection ef؀ciency, minimizes cytotoxicity, and results in the desired level of gene expression or silencing. EMD Millipore recognizes that there is not a one-size-؀ts-all solution to your transfection needs. We provide the breadth of transfection reagents necessary to give you the freedom to design the perfect experiment.

查看全部

Questions

  1. Can these 5 layer flasks be stacked atop each other?

    1 answer
    1. Yes, these can be stacked upon each other. Please see the helpful User Guide.

      Helpful?

Reviews

No rating value

Active Filters

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務