All standards in the Rat Cytokine Milliplex kit RECYTMAG-65K are recombinant. They are all from rat except for G-CSF and IL-17A, which are from mouse, and Eotaxin, which is from human.
品質等級
物種活性
rat
製造商/商標名
Milliplex®
assay range
accuracy: 80-131%
standard curve range: 0.2-1,000 pg/mL
(EGF)
standard curve range: 1.2-5,000 pg/mL
(GRO/KC)
standard curve range: 12.2-50,000 pg/mL
(GM-CSF, IL-1α, IL-2, IL-12 (p70), IL-18)
standard curve range: 14.6-60,000 pg/mL
(IFNγ, MIP-1α)
standard curve range: 2.4-10,000 pg/mL
(Fractalkine, IP-10, Leptin, TNFα)
standard curve range: 24.4-100,000 pg/mL
(LIX, MIP-2)
standard curve range: 4.9-20,000 pg/mL
(Eotaxin, C-CSF, IL-4, IL-5, IL-13, RANTES, VEGF)
standard curve range: 7.3-30,000 pg/mL
(IL-10, IL-17A, MCP-1)
standard curve range: 73.2-300,000 pg/mL
(IL-6)
技術
multiplexing: suitable
相容性
configured for Premixed
檢測方法
fluorometric (Luminex xMAP)
運輸包裝
wet ice
1 of 4
本產品 | RECYMAG65PMX27BK | CCYTMAG90KPX13BK | HCD8MAG15K17PMX |
|---|---|---|---|
| species reactivity rat | species reactivity rat | species reactivity canine | species reactivity human |
| manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® |
| assay range accuracy: 80-131%, standard curve range: 1.2-5,000 pg/mL | assay range - | assay range accuracy: 101% | assay range - |
| Quality Level 200 | Quality Level 200 | Quality Level 200 | Quality Level 200 |
| technique(s) multiplexing: suitable | technique(s) multiplexing: suitable | technique(s) multiplexing: suitable | technique(s) multiplexing: suitable |
| compatibility configured for Premixed | compatibility configured for Premixed | compatibility configured for Premixed | compatibility configured for Premixed |
一般說明
组套类型:细胞因子/趋化因子
應用
- 分析物:EGF、嗜酸性粒细胞趋化因子/CCL11、Fractalkine、G-CSF、GM-CSF、Gro/KC、IFN-γ、IL-1α、IL-1β、IL-2、IL-4、IL-5、IL-6、IL-10、IL-12(p70)、IL-13、IL-17A、IL-18、IP-10、瘦素、LIX、MCP-1α、MIP-1、MIP-2、RANTES、TNF-α、VEGF
- 建议的样品类型:大鼠血清或血浆
- 建议的样品稀释度:1:2
- 分析运行时间:一天。
生化/生理作用
抗体与面板中的任何其他分析物之间没有交叉反应性或交叉反应性最小。
其他說明
法律資訊
訊號詞
Danger
危險分類
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
標靶器官
Respiratory Tract
儲存類別代碼
10 - Combustible liquids
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。
-
Are all the standards in the Rat Cytokine Milliplex kit RECYTMAG-65K rat standards, and are they recombinant?
1 answer-
Helpful?
-
Active Filters
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.