跳轉至內容
Merck

57298-U

SPME萃取头组件

greener alternative

50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, plain gray hub

同義詞:

DVB/CAR/PDMS SPME萃取头组件

登入 檢視組織與合約價格。

選擇尺寸

暫時無法取得訂價和供貨情況

關於此項目

UNSPSC Code:
41115724
NACRES:
NB.21

跳轉至

技術服務
需要援助?我們經驗豐富的科學家團隊隨時樂意為您提供支援。
讓我們為您提供幫助

產品名稱

SPME萃取头组件, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, plain gray hub

material

StableFlex fiber
plain gray hub

needle size

23 ga

packaging

pk of 3

greener alternative product characteristics

Waste Prevention
Safer Solvents and Auxiliaries
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

df

30 μm (CAR/PDMS layer)
50 μm (DVB layer)

technique(s)

solid phase microextraction (SPME): suitable

fiber L

1 cm

matrix active group

50/30µm DVB/CAR/PDMS
DVB/CAR/PDMS coating

application(s)

food and beverages

compatibility

Autosampler
for analyte group flavors (volatiles and semivolatiles, C3-20) (MW 40-275)

greener alternative category

Quality Level

尋找類似的產品? 前往 產品比較指南

比較類似項目

查看完整比較

Show Differences

1 of 4

本產品
57293-U57329-U57348-U
material

StableFlex fiber, plain gray hub

material

(Polydimethylsiloxane/Divinylbenzene (PDMS/DVB)), StableFlex fiber, plain pink hub

material

StableFlex fiber, plain gray hub

material

StableFlex fiber, notched gray hub

compatibility

Autosampler, for analyte group flavors (volatiles and semivolatiles, C3-20) (MW 40-275)

compatibility

for analyte group volatiles, amines, and nitroaromatic compounds (MW 50-300), for use with autosampler

compatibility

for analyte group flavors (volatiles and semivolatiles, C3-20) (MW 40-275), for use with autosampler

compatibility

for analyte group flavors (volatiles and semivolatiles, C3-20) (MW 40-275), for use with autosampler

matrix active group

DVB/CAR/PDMS coating

matrix active group

PDMS/DVB coating

matrix active group

DVB/CAR/PDMS coating

matrix active group

DVB/CAR/PDMS coating

df

30 μm (CAR/PDMS layer)

df

65 μm (PDMS/DVB)

df

30 μm (CAR/PDMS layer), 50 μm (DVB layer)

df

30 μm (CAR/PDMS layer), 50 μm (DVB layer)

needle size

23 ga

needle size

23 ga

needle size

24 ga

needle size

24 ga

packaging

pk of 3

packaging

pkg of 3 ea

packaging

pk of 3

packaging

pk of 3

Application

SPME纤维束二乙烯基苯/羧基/聚二甲硅氧烷(DVB/CAR/PDMS)用于通过顶空-固相微萃取法以及气相色谱与质谱联用的方法分析历史性塑料和橡胶材料的VOC排放。[1]

Features and Benefits

设计与 Merlin Microseal 密封系统结合使用;可与其他无隔垫的系统一起使用。

General description

我们竭诚为您带来绿色替代产品,以符合绿色化学12项原则的一项或多项要求。本品为固相微萃取(SPME)技术产品。SPME是绿色环保的样品制备技术,包括采用无溶剂萃取技术、SPME纤维萃取头可重新利用、产生的废弃物极少,符合“废物预防”和“安全的溶剂和助剂”原则。点击 此处 以获取更多信息。

Other Notes

外观可能会有所不同。纤维头上可能可见较暗的斑点,但不会影响性能。
键合到柔性熔融石英芯层上的涂层,在更不易断裂的萃取头上获得更合适的涂层。与在标准熔融石英芯层上的同样涂层相比,在萃取选择性上略有区别。

從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

The development of a SPME-GC/MS method for the analysis of VOC emissions from historic plastic and rubber materials.
Curran K, et al.
Microchemical Journal, Devoted to the Application of Microtechniques in All Branches of Science, 124, 909-918 (2016)
Johannes Kiefl et al.
Journal of chromatography. A, 1243, 81-90 (2012-05-11)
The continuous interest in non-targeted profiling induced the development of tools for automated cross-sample analysis. Such tools were found to be selective or not comprehensive thus delivering a biased view on the qualitative/quantitative peak distribution across 2D sample chromatograms. Therefore
Amparo Gamero et al.
Journal of chromatography. A, 1272, 1-7 (2012-12-19)
MicroVinification platforms are used for screening purposes to study aroma development in wine. These high-throughput methodologies require flavor analysis techniques that allow fast detection of a high number of aroma compounds which often appear in very low concentrations (μg/l). In
Sanja Risticevic et al.
Journal of chromatography. A, 1251, 208-218 (2012-07-10)
Metabolomics currently represents one of the fastest growing high-throughput molecular analysis platforms that refer to the simultaneous and unbiased analysis of metabolite pools constituting a particular biological system under investigation. In response to the ever increasing interest in development of
Sílvia M Rocha et al.
Journal of chromatography. A, 1252, 155-163 (2012-07-11)
Metabolomics represents an emerging issue that can aid in the diagnosis and/or prognosis of different diseases. Metabolomic study of urine is particularly interesting as it can be on the base of the developing of new faster and non-invasive methodologies. In

文章

A throughput HS-SPME-GC-MS method to analyze volatile compounds in Perilla leaves at low extraction temperatures using four different SPME fibers.

The work describes the development of an HS-SPME-GC-MS method to determine 2-chloroethanol as a marker of fumigant ethylene oxide in different kinds of sesame seed samples.

條款

SPME offers efficient sample preparation for analyzing terpene/terpenoid profiles in plant essential oils using automation.

GC Analysis of Terpenes in Cannabis on Equity®-1 after Headspace SPME using 50/30 μm DVB/CAR/PDMS Fiber

In this article, SPME-GC was successfully used to identify many volatile compounds present in the headspace over several spirits.

High performance, reliability, and reproducibility of HS-SPME in combination with GC/MS for the determination of VOCs in water was proven in an interlaboratory trial. The new ISO 17943 using HS-SPME is an improvement on existing official methods for this determination in terms of sensitivity and selectivity.

查看全部

相關內容

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. Which gauge is larger, 23 or 24?

    1 answer
    1. The gauge designation and actual size of needles follow an inverse relationship. Therefore, a 24 gauge needle is smaller than a 23 gauge needle. Needle gauge sizes also apply to the SPME needle used for sampling. While the original SPME fibers were manufactured with 24 gauge needles, it is highly recommended to use 23 gauge needles for all applications that involve an autosampler. The 23 gauge needles are well-suited for use with the Merlin Microseal septum system and other septum-less seals. However, it is advisable to avoid using 23 gauge needles with standard silicone septa, as they may cause coring of the septum.

      Helpful?