This product is packaged in a bottle with S40 threads. The neck of the bottle has an outer diameter of 40 millimeters, and an inner diameter of 26 to 27 millimeters.
Sélectionner une taille de conditionnement
| À vous/Référence | Disponibilité | Prix |
|---|---|---|
1 L | Vérifier la disponibilité des articles du panier | 80,00 € |
1 L | Vérifier la disponibilité des articles du panier | 83,90 € |
A propos de cet article
Nom du produit
Hydroxyde de potassium en solution dans l′isopropanol, acc. to DIN ISO 6618 part 1 c(KOH)=0.1 mol/l (0,1 N), Titripur®
Quality Segment
product line
Titripur®
form
liquid
autoignition temp.
425 °C (2-Propanol)
quality
Analyzed in our ISO 17025 accredited QC lab
expl. lim.
2-13.4 % (v/v) 2-Propanol()
reaction suitability
reaction type: Acid-base reactions
concentration
0.1 M
technique(s)
titration: suitable
pH
13 (20 °C in H2O)
transition temp
flash point 12 °C (2-Propanol)
density
0.79 g/cm3 at 20 °C
storage temp.
15-25°C
Features and Benefits
ChemiSphere™ App for Digital Data Transfer to OMNIS Titration Instruments from Metrohm
Discover the ChemiSphere™ App for secure, rapid data transfer to OMNIS titrators, enhancing efficiency in the titration workflow with Titripur® and Aquastar® reagents. ChemiSphere App for Digital Reagent Data Transfer
SmartChemicals for Digital Data Transfer to Mettler Toledo Titration Instruments
Explore digital data transfer with our SmartChemicals for Mettler Toledo titrators—fast, easy, and safe, accelerating the titration process with Titripur®, Aquastar® reagents, and Certipur® and Aquastar® standards. Supelco® SmartChemicals for Titration
Cette solution volumétrique est analysée par notre laboratoire d'étalonnage, qui est accrédité par l'organisme d'accréditation allemand DAkkS (Deutsche Akkreditierungsstelle) selon la norme DIN EN ISO/CEI 17025 pour l'analyse des concentrations en quantité de matière des solutions volumétriques (numéro d'accréditation : D-K-15185-01-00). L'attestation d'accréditation est disponible ici : www.sigmalaldrich.com/ISO17025
Packaging
Analysis Note
Concentration en quantité de matière : 0,0995 à 0,1005 mol/l
Incertitude de mesure : ± 0,0003 mol/l
Traçabilité métrologique jusqu'aux matériaux de référence du NIST
La concentration est déterminée par titrage volumétrique à une température de référence de 20 °C.
La traçabilité métrologique de la concentration en quantité de matière de cette solution volumétrique peut être établie jusqu'à un matériau de référence ("Standard Reference Material", SRM) du National Institute of Standards and Technology (NIST) de Gaithersburg aux États-Unis (l'hydrogénophtalate de potassium, SRM 84), avec l'hydrogénophtalate de potassium, étalon volumétrique (réf. 1.02400), matériau de référence certifié conforme à la norme ISO 17034 et analysé par le laboratoire d'étalonnage de Merck KGaA Darmstadt (Allemagne) accrédité DIN EN ISO/CEI 17025. L'incertitude est exprimée sous la forme d'une incertitude de mesure élargie avec un facteur d'élargissement k = 2 couvrant un niveau de confiance de 95 %.
Remarque : Le titre est un facteur de correction qui permet de tenir compte des variations de la solution volumétrique, du matériel de titrage, ainsi que de la température et autres conditions de laboratoire. Pour obtenir des résultats de titrage corrects, il est recommandé de déterminer un titre avec le matériel et dans les conditions spécifiques au laboratoire, directement après ouverture d'un nouveau flacon et à intervalles réguliers.
*) La concentration de cette solution volumétrique diminue au cours de son stockage. Il ne s'agit pas d'un problème de qualité, mais d'une caractéristique propre à cette solution. Nous vous recommandons donc de la titrer après avoir ouvert le flacon scellé ainsi qu'avant chaque journée de travail.
Legal Information
1 of 1
Cet article | |||
|---|---|---|---|
| description acc. to DIN ISO 6618 part 1 c(KOH)=0.1 mol/l (0,1 N), Titripur® | description 4 M, eluent concentrate for IC | description (max. 0.00004% Ca) c(KOH) = 1 mol/l (1 N), Titripur® | description c(KOH) = 1 mol/l (1 N), Titripur®, reag. USP |
| reaction suitability reaction type: Acid-base reactions | reaction suitability - | reaction suitability reaction type: Acid-base reactions | reaction suitability reaction type: Acid-base reactions |
| technique(s) titration: suitable | technique(s) - | technique(s) titration: suitable | technique(s) titration: suitable |
| product line Titripur® | product line - | product line Titripur® | product line Titripur® |
| Quality Level 200 | Quality Level 100 | Quality Level 100 | Quality Level 200 |
| expl. lim. 2-13.4 % (v/v) 2-Propanol() | expl. lim. - | expl. lim. - | expl. lim. - |
| pH 13 (20 °C in H2O) | pH - | pH 14 (20 °C in H2O) | pH 14 (20 °C in H2O) |
Still not finding the right product?
Explore all of our products under Hydroxyde de potassium en solution dans l′isopropanol
signalword
Danger
Hazard Classifications
Eye Irrit. 2 - Flam. Liq. 2 - Met. Corr. 1 - Skin Irrit. 2 - STOT SE 3
target_organs
Central nervous system
Classe de stockage
3 - Flammable liquids
hcodes
flash_point_f
53.6 °F - closed cup - (2-Propanol)
flash_point_c
12 °C - closed cup - (2-Propanol)
Listes réglementaires
Les listes réglementaires sont principalement fournies pour les produits chimiques. Seules des informations limitées peuvent être fournies ici pour les produits non chimiques. L'absence d'indication signifie qu'aucun des composants n'est répertorié. Il incombe à l'utilisateur de s'assurer de l'utilisation sûre et légale du produit.
67-63-0
Faites votre choix parmi les versions les plus récentes :
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
-
Hi, What is the neck size of this bottle, 32 mm?
1 réponse-
Utile ?
-
-
How can I determine the shelf life / expiration / retest date of this product?
1 réponse-
If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdfUtile ?
-
-
Does this reactive meet ASTM D974 specifications?
1 réponse-
This item does not meet ASTM D974 specifications. Currently, there is no product option available that meets ASTM D974 specifications.
Utile ?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 réponse-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Utile ?
-