1.09112

Potassium hydroxide solution

c(KOH) = 0.1 mol/l (0.1 N), reag. Ph. Eur., ready-to-use volumetric solution for titration, Titripur®

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
1 L
Check Cart for Availability
$44.30
1 L
Check Cart for Availability
$46.60

About This Item

Linear Formula:
KOH
CAS Number:
Molecular Weight:
56.11
NACRES:
NA.21
UNSPSC Code:
12352305
MDL number:

$44.30


Check Cart for Availability

​
Request more information
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

Potassium hydroxide solution, c(KOH) = 0.1 mol/l (0.1 N), Titripur®, reag. Ph. Eur.

agency

reag. Ph. Eur.

Quality Segment

product line

Titripur®

form

liquid

quality

Analyzed in our ISO 17025 accredited QC lab

reaction suitability

reaction type: Acid-base reactions

concentration

0.1 M

technique(s)

titration: suitable

pH

13 (20 °C in H2O)

bp

100 °C

density

1.00 g/cm3 at 20 °C

storage temp.

15-25°C

SMILES string

[K+].[O-][H]

InChI

1S/K.H2O/h;1H2/q+1;/p-1

InChI key

KWYUFKZDYYNOTN-UHFFFAOYSA-M

Application

  • Chemical and morphological analysis of explanted polyurethane vascular prostheses: the challenge of removing fixed adhering tissue.: This study details the use of potassium hydroxide solution for chemical analysis in the examination of explanted polyurethane vascular prostheses, focusing on challenges related to removing tissue that remains adhered to the biomaterials (Zhang et al., 1996). (Zhang et al., 1996).

Features and Benefits

Digital Titration

ChemiSphere™ App for Digital Data Transfer to OMNIS Titration Instruments from Metrohm

Discover the ChemiSphere™ App for secure, rapid data transfer to OMNIS titrators, enhancing efficiency in the titration workflow with Titripur® and Aquastar® reagents. ChemiSphere App for Digital Reagent Data Transfer



SmartChemicals for Digital Data Transfer to Mettler Toledo Titration Instruments

Explore digital data transfer with our SmartChemicals for Mettler Toledo titrators—fast, easy, and safe, accelerating the titration process with Titripur®, Aquastar® reagents, and Certipur® and Aquastar® standards. Supelco® SmartChemicals for Titration
Accreditation:
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.

Packaging

SKU-pack size numbers ending with a "3" are SmartChemicals with an RFID tag on the label for seamless data transfer to the instrument, e.g. xxxxxx1003 or xxxxxxx 4003. More information on www.sigmaaldrich.com/SmartChemicals

Analysis Note

Form liquid
Amount-of-substance concentration 0.0995 - 0.1005 mol/L
Measurement uncertainty ± 0.0003 mol/L
Traceability NIST SRM

The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 84 potassium hydrogen phthalate) by means of volumetric standard potassium hydrogen phthalate (article number 1.02400), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.

Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.

Legal Information

AQUASTAR is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIPUR is a registered trademark of Merck KGaA, Darmstadt, Germany
ChemiSphere is a trademark of Merch KGaA, Darmstadt, Germany
Supelco is a registered trademark of Merck KGaA, Darmstadt, Germany
Titripur is a registered trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?

Explore all of our products under Potassium hydroxide solution


Pictograms

Corrosion

Signal Word

Warning

Hazard Classifications

Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

Hazard Codes

Storage Class

12 - Non Combustible Liquids



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–3 of 3 Questions  
  1. Could you please provide the impurity specifications (including Fe, Ni, Cu, and Pb) and carbonate (CO₃²⁻)? What measures are taken during production and packaging to prevent contamination by CO₂ from ambient air and metals?

    1 answer
    1. The product has no specification for metals content. This is a volumetric solution intended for titration. It is prepared in accordance to the procedure described in the reagents part for the preparation of volumetric solutions of the European Pharmacopoeia (Ph. Eur.), using raw materials and water that comply with the relevant Ph. Eur. requirements and specification. For this type of solution, the key release test is an accurate determination of its concentration (titer) after production with a certified reference material. Additional testing for specific impurities in the finished solution is not required under the applicable compendial approach.
      Production and filling procedures are in place to minimize carbon dioxide exposure including the production of the pharmaceutical grade ware we use. The solution is packaged in high-quality HDPE bottles designed to provide a strong barrier against air, CO2 and moisture. These measures support a three-year shelf life for an unopened, original closed bottle when stored as specified.
      The titer is determined after production and again after filling, using samples from multiple bottles. The nominal concentration is stated on the Certificate of Analysis and only released when it is in the very narrowly defined specification range.
      Once a bottle has been opened and is in use, exposure to air can lead to carbon dioxide uptake and may affect the solution's concentration. For this reason, we recommend periodic titer determination during use, in line with your procedures and the solution's intended application.
      To protect the solution during use, attach a drying tube containing soda lime when the bottle is connected to the titrator burette. Alternatively, use a glass stopcock and close it whenever the titrator is not in use.

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters