Skip to Content
MilliporeSigma

Skip To

431508

Tin(II) chloride dihydrate

ACS reagent grade, ≥99.99% trace metals basis

Synonym(s):

Stannous chloride dihydrate

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
50 g
Check Cart for Availability
$143.00
250 g
Check Cart for Availability
$502.00

About This Item

Linear Formula:
SnCl2 · 2H2O
CAS Number:
Molecular Weight:
225.65
NACRES:
NA.22
PubChem Substance ID:
UNSPSC Code:
12161600
EC Number:
231-868-0
MDL number:

$143.00


Check Cart for Availability

​
Request a Custom Order
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

Tin(II) chloride dihydrate, ≥99.99% trace metals basis

grade

ACS reagent

Quality Segment

assay

≥99.99% trace metals basis

reaction suitability

core: tin, reagent type: inorganic catalyst

bp

652 °C

mp

37-38 °C (dec.) (lit.)

cation traces

Ca: ≤0.005%, Fe: ≤0.003%, K: ≤0.005%, Na: ≤0.01%, Pb: ≤0.01%

SMILES string

O.O.Cl[SnH2]Cl

InChI

1S/2ClH.2H2O.Sn/h2*1H;2*1H2;/q;;;;+2/p-2

InChI key

FWPIDFUJEMBDLS-UHFFFAOYSA-L

Application

Reducing agent; carbonyl allylation; Lewis acid catalyst in C-C bond-forming reactions; catalyst withAgClO4 for the synthesis of α-glycosides; synthesis of alkenes, dienes, cis-vinyloxiranes, and allylic selenides; deoxygenation of 1,4-endoperoxides; protection of carboxylic acids as 1,3-dithianes;selective p-methoxybenzyl ether cleavage reagent; additive in hydroformylation and carbonylation reactions.

Features and Benefits

Meets A.C.S. reagent specifications.

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
474762243523208035
description

≥99.99% trace metals basis

description

≥99.97% trace metals basis

description

ACS reagent, 98%

description

reagent grade, 98%

reaction suitability

core: tin, reagent type: catalyst

reaction suitability

core: tin, reagent type: catalyst

reaction suitability

reagent type: catalyst
core: tin

reaction suitability

-

assay

≥99.99% trace metals basis

assay

≥99.97% trace metals basis

assay

98%, 98.0-103.0% (ACS specification)

assay

98%

Quality Level

100

Quality Level

100

Quality Level

200

Quality Level

200

mp

37-38 °C (dec.) (lit.)

mp

37-38 °C (dec.) (lit.)

mp

37-38 °C (dec.) (lit.)

mp

37-38 °C (dec.) (lit.)

cation traces

Fe: ≤0.003%, Na: ≤0.01%, Ca: ≤0.005%, K: ≤0.005%, Pb: ≤0.01%

cation traces

-

cation traces

Pb: ≤0.01%, K: ≤0.005%, Na: ≤0.01%, Fe: ≤0.003%, Ca: ≤0.005%

cation traces

-

grade

ACS reagent

grade

-

grade

ACS reagent

grade

reagent grade


Still not finding the right product?

Explore all of our products under Tin(II) chloride dihydrate


Signal Word

Danger

Hazard Classifications

Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1B - Skin Sens. 1 - STOT RE 2 Oral - STOT SE 3

Target Organs

Cardio-vascular system, Respiratory system

Storage Class

8B - Non-combustible corrosive hazardous materials

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

PPE (personal protective equipment)

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters