About This Item
$1,120.00
usage
sufficient for 50 tests
Quality Segment
manufacturer/tradename
Calbiochem®
storage condition
OK to freeze
assay range
standard curve range: 0-2.5 mM
(plasma)
input
sample type serum
sample type plasma
sample type tissue extract(s)
sample type beverage(s)
sample type plant extract(s)
detection method
colorimetric
shipped in
ambient
storage temp.
2-8°C
General description
Biochem/physiol Actions
Preparation Note
• Substrate: Dilute each vial of Substrate needed for the assay by adding 7.5 ml Buffer. After dilution, the substrate is stable for 24 h at 4°C. NOTE: Some automated methods do not require substrate dilution.
• Standard: Add 1 ml distilled water to each vial of Standard needed for the assay. After reconstitution, the Standard is stable for 2 days at 4°C or 1 month at -20°C.
Analysis Note
1. Determine the ΔA for the samples, standard, and blank. ΔA = A - Ao
2. Calculate the concentration of antioxidants in the sample using the formula below:
<div class="Bio_doc_image">Figure 2: Antioxidant Concentration Formula
</div>
NOTE: If the antioxidant concentration is greater than 2.5 mM dilute the sample with 0.9% NaCl and re-assay. Typical antioxidant levels in normal human plasma are 1.30-1.77 mM.
Other Notes
Legal Information
Disclaimer
1 of 1
This Item | |||
|---|---|---|---|
| description - | description sufficient for 200 tests | description sufficient for 100 colorimetric tests | description - |
| storage condition OK to freeze | storage condition - | storage condition - | storage condition OK to freeze |
| manufacturer/tradename Calbiochem® | manufacturer/tradename - | manufacturer/tradename - | manufacturer/tradename Calbiochem® |
| Quality Level 100 | Quality Level 200 | Quality Level - | Quality Level 100 |
| assay range standard curve range: 0-2.5 mM | assay range - | assay range - | assay range - |
| detection method colorimetric | detection method colorimetric | detection method colorimetric | detection method colorimetric |
| usage sufficient for 50 tests | usage sufficient for 200 tests | usage sufficient for 100 colorimetric tests | usage sufficient for 96 tests |
signalword
Warning
hcodes
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
target_organs
Respiratory system
Storage Class
10 - Combustible liquids
wgk
WGK 3
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.