Skip to Content
MilliporeSigma

Skip To

SCC468

T24T Human Bladder Carcinoma Cell Line

Human

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
1 vial
Check Cart for Availability
$1,130.00

About This Item

UNSPSC Code:
41106514
NACRES:
NA.81
Biological source:
human
Growth mode:
N/A
Manufacturer/tradename:
Millipore

$1,130.00


Check Cart for Availability

​
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

T24T Human Bladder Carcinoma Cell Line,

biological source

human

Quality Segment

packaging

vial of ≥1X10⁶ cells/vial mg

manufacturer/tradename

Millipore

growth mode

N/A

technique(s)

cell analysis: suitable

shipped in

liquid nitrogen

storage temp.

−196°C

Application

Bladder cancer originates from the epithelium that covers the inner surface of the bladder. The most common type is urothelial or transitional carcinoma (1). Most of the newly diagnosed cases (75%) are non-invasive, if the tumor becomes invasive it is more likely to metastasize to lymph nodes and other organs. Two common alterations have been identified in non-invasive tumors, deletion of chromosome 9 and a point mutation in FGFR3 (Fibroblast growth factor receptor 3) (2). Activating mutations in RAS gene family members are also common in bladder carcinoma and it is estimated that activation of the RAS-MAPK pathway may contribute to over 80% of the non-invasive cases (1). Loss of function of tumor suppressor genes like TP53 and RB1 are common in cases of invasive disease (1). After diagnosis the patient requires resection of the tumor and in cases of invasive disease chemotherapy is also provided.The original cell line T24 has been used to study bladder tumor biology but has some limitations because it lacks tumorigenicity when injected into immunocompromised mice. In contrast, T24T has increased metastatic ability when tested in vivo and expresses higher levels of HRAS mRNA (3). Increased HRAS activity leads to focal adhesion disassembly and los of CDH1 and b-catenin from intercellular junctions (3). Contact inhibition growth is reduced in T24T compared with T24 (3). Additionally, T24T does not inhibit its motile activity at higher density like T24 does.T24 cell line was generated from an invasive human transitional cell carcinoma of the bladder (4). T24T is a derivative of T24.1. Nat Rev Dis Primers 2017, 3: 17022.2. Int J Cancer 2006, 119(5): 1212-1215.3. Genes Chromosomes Cancer 2000, 27(3): 252-263.4. Int J Cancer 1973, 11(3): 765-773.
Each vial contains ≥1X10⁶ viable cells.Cells are tested negative for infectious diseases by a Human Essential CLEAR panel by Charles River Animal Diagnostic Services.Cells are verified to be of human origin and negative for inter-species contamination from mouse, rat, Chinese hamster, Golden Syrian hamster, and Non-human Primate (NHP) as assessed by a Contamination Clear panel by Charles River Animal Diagnostic Services Cells are negative for mycoplasma contamination.

Features and Benefits

T24T human bladder cancer cell line is a useful model for the study of metastatic bladder cancer.

Preparation Note

Store in liquid nitrogen. The cells can be cultured for at least 10 passages after initial thawing without significantly affecting the cell marker expression and functionality.

Other Notes

Subject to local law, this product is intended to be sold for internal in vitro research use only subject to terms and conditions found here: www.sigmaaldrich.com/restrictedcelluse. This product may not be: re-engineered or copied; used to make derivatives, modifications or functional equivalents; used to obtain patents or other IP claiming use of the product; used to develop, test, or manufacturer a commercial product; used as a component in a commercial product; resold or licensed; used in any clinical applications or trials; or used in humans. A license or limited commercial use agreement is required for use by any for-profit entity, use in services, and use in sponsored academic research. For information regarding any such use, please contact licensing@milliporesigma.com.

Disclaimer

This product is regulated in France when intended for scientific purposes, including import, export, and conservation activities (Articles L.1211-1, paragraph 2, and L.1243-4 of the French Public Health Code). The purchaser (i.e. end user) is required to obtain an import authorization from the France Ministry responsible for Research (as referenced in Article L.1245-5-1 II of the French Public Health Code) or a conservation authorization from the same ministry (as referenced in Article L.1243-4 of the French Public Health Code). By placing an order for this product, you confirm that you have obtained the appropriate import or conservation authorization for the product. For more information regarding the use of human biological samples for research purposes in France, please contact the relevant French authorities.
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
SCC642SCC624SCC426
description

-

description

-

description

-

description

-

biological source

human

biological source

human

biological source

mouse

biological source

human

growth mode

N/A

growth mode

-

growth mode

-

growth mode

N/A

technique(s)

cell analysis: suitable

technique(s)

cell culture | mammalian: suitable

technique(s)

cell culture | mammalian: suitable

technique(s)

cell culture | mammalian: suitable

storage temp.

−196°C

storage temp.

−196°C

storage temp.

−196°C

storage temp.

−196°C

shipped in

liquid nitrogen

shipped in

liquid nitrogen

shipped in

liquid nitrogen

shipped in

dry ice

Quality Level

100

Quality Level

100

Quality Level

100

Quality Level

-


Storage Class

10 - Combustible liquids

WGK

WGK 2

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

Reviews

No rating value

Active Filters