If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf
Select a Size
| Size/SKU | Availability | Price |
|---|---|---|
5 g | Check Cart for Availability | $105.00 |
About This Item
grade
analytical standard
Quality Segment
vapor pressure
1 mmHg ( 108 °C)
quality
traceable to primary standards (LGC)
shelf life
limited shelf life, expiry date on the certificate and label
bp
305 °C (lit.)
mp
47-51 °C (lit.)
application(s)
food and beverages
pharmaceutical
format
neat
SMILES string
O=C(C1=CC=CC=C1)C2=CC=CC=C2
InChI
1S/C13H10O/c14-13(11-7-3-1-4-8-11)12-9-5-2-6-10-12/h1-10H
InChI key
RWCCWEUUXYIKHB-UHFFFAOYSA-N
General description
Application
Features and Benefits
- Melting point calibration standard traceable to a primary standard from LGC, London
- Melting point evaluation performed in both thermodynamic and pharmacopeia modes for physically correct and heating rate dependent melting point determinations, respectively
- Available with certificates of analysis and safety data sheet
- A product of analytical standard grade to help meet the QC/QA requirements of melting point determination
1 of 1
This Item | |||
|---|---|---|---|
| description traceable to primary standards (LGC) | description purified by sublimation, ≥99% | description Pharmaceutical Secondary Standard; Certified Reference Material | description European Pharmacopoeia (EP) Reference Standard |
| format neat | format - | format neat | format neat |
| mp 47-51 °C (lit.) | mp 47-51 °C (lit.) | mp 47-51 °C (lit.) | mp 47-51 °C (lit.) |
| bp 305 °C (lit.) | bp 305 °C (lit.) | bp 305 °C (lit.) | bp 305 °C (lit.) |
| grade analytical standard | grade - | grade certified reference material, pharmaceutical secondary standard | grade pharmaceutical primary standard |
| application(s) food and beverages | application(s) - | application(s) cleaning products | application(s) pharmaceutical (small molecule) |
| vapor pressure 1 mmHg ( 108 °C) | vapor pressure 1 mmHg ( 108 °C) | vapor pressure 1 mmHg ( 108 °C) | vapor pressure 1 mmHg ( 108 °C) |
Signal Word
Danger
Hazard Codes
Precautionary Statements
Hazard Classifications
Aquatic Chronic 3 - Carc. 1B - STOT RE 2 Oral
Target Organs
Liver,Kidney
Storage Class
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Flash Point (°F)
280.4 °F - closed cup
Flash Point (°C)
138 °C - closed cup
PPE (personal protective equipment)
dust mask type N95 (US), Eyeshields, Gloves
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
Helpful?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Helpful?
-
-
Are the Mettler-Toledo Calibration melting standards already dried and pulverized, ready to use out of the bottle?
1 answer-
The answer is yes. All melting point standards are ground to a fine powder, tested as melting point standards and ready to use.
Helpful?
-
-
What is the Department of Transportation shipping information for this product?
1 answer-
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
Helpful?
-