Saltar al contenido
Merck

Saltar a

C7901

Chelex® 100 sodium form

50-100 mesh (dry)

Sinónimos:

Iminodiacetic Acid Resin

Iniciar sesión para ver los precios por organización y contrato.

Seleccione un Tamaño

Cambiar Vistas
A ustedes/SKUDisponibilidadPrecio
25 g
Comprobar disponibilidad del carrito
US$ 168,00
50 g
Comprobar disponibilidad del carrito
US$ 297,00
100 g
Comprobar disponibilidad del carrito
US$ 539,00
500 g
Comprobar disponibilidad del carrito
US$ 1.860,00

Acerca de este artículo

Número CAS:
UNSPSC Code:
23151817
NACRES:
NA.56
MDL number:

US$ 168,00

PRECIOS SIN IMPUESTOS NACIONALES

Comprobar disponibilidad del carrito

Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle


form

beads

Quality Segment

matrix

1% cross-linked polystyrene, cross-linked polystyrene beads

matrix active group

iminodiacetic acid (sodium form), paired iminodiacetate groups

matrix attachment

through methyl group to aromatic rings

particle size

50-100 mesh (dry)

pH

4-14

capacity

≥0.3 meq/mL binding capacity, 0.6 meq/g binding capacity (heavy metal ions)

Application

Chelex se utiliza en la cromatografía de afinidad, la cromatografía de proteínas, las resinas quelantes, las resinas de afinidad y los biorreactivos centrales.
La forma sódica de Chelex® 100 se ha utilizado:
  • para la extracción de ADN de muestras de abejas
  • para eliminar del extracto de humo de los cigarrillos (CSE) y estudiar los efectos de la expresión de la hepcidina en los pulmones murinos[1]
  • para extraer ADN de cultivos bacterianos

Biochem/physiol Actions

Chelex® 100 es un copolímero de estireno-divinilbenceno que contiene iones de iminodiacetato emparejados, que actúan como grupos quelantes en la unión de iones metálicos polivalentes. Se considera una resina débilmente ácida. Chelex actúa como una resina quelante que se utiliza en la extracción del ADN de muestras forenses, como el cabello, las tarjetas con manchas de sangre seca y los hisopos bucales.

Other Notes

El producto es esterilizable en autoclave en su forma sódica Tiene una temperatura de funcionamiento máxima de 75 °C y no es soluble en agua.

Legal Information

Chelex is a registered trademark of Bio-Rad Laboratories, Inc.

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 1

Este artículo
9557795621217417
description

50-100 mesh (dry)

description

100-200 mesh particle size

description

200-400 mesh particle size

description

-

form

beads

form

crystals

form

powder or chunks

form

beads

particle size

50-100 mesh (dry)

particle size

100-200 mesh

particle size

200-400 mesh

particle size

50-100 mesh

pH

4-14

pH

-

pH

-

pH

-

matrix

1% cross-linked polystyrene, cross-linked polystyrene beads

matrix

polystyrene/DVB

matrix

polystyrene/DVB

matrix

styrene-divinylbenzene (gel)

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

100

capacity

≥0.3 meq/mL binding capacity, 0.6 meq/g binding capacity (heavy metal ions)

capacity

-

capacity

-

capacity

1.2 meq/mL by wetted bed volume


Still not finding the right product?

Explore all of our products under Chelex® 100 sodium form


Clase de almacenamiento

11 - Combustible Solids

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)



Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos



Questions

1–10 of 11 Questions  
  1. Bonjour, pourriez-vous m'expliquer pourquoi vous indiquez le mot "dry" sur le nom de la résine Chelex100 alors que le fabricant, qui est Bio-Rad, indique que son aspect est liquide dans ses FDS ?

    1 answer
    1. The term “dry” refers to the mesh range in the dry state. This product is hydrated and supplied as pre-swollen beads, which may appear moist or slurry-like. Should the resin dry out, rehydration is possible, provided the resin remains white. Do not use if the resin turns yellow, as this may indicate degradation. Please see the link below to review additional information available in the product datasheet:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/200/928/c7901pis.pdf

      Helpful?

  2. I want to use this resin to extract the salts and retain the metals for analysis of the metal content in seawater samples. Is there any documentation on how to use the solvent and pH?

    1 answer
    1. This product has been used for trace metal studies, but the application has not been validated internally. Usage instructions can be reviewed in the product datasheet available at: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/200/928/c7901pis.pdf

      Helpful?

  3. Can this resin be used with organic solvents (such as DMF, DMSO) in order to remove Cu ? For example in solid-phase peptide synthesis?

    1 answer
    1. The base matrix of the resin is styrene divinylbenzene which is chemically compatible with organic solvents at low concentrations.

      Chelex 100 resin is not damaged by 100% organics, but it IS affected.

      1) The functional group will lose its polarity and metals won't exchange onto the resin:

      2) Chelex 100 resin will not work as an ion exchanger in 100% organic solvent.

      3) In studies, Chelex 100 resin removed metal ions well in either 20 or 40% ethanol. End users should verify the efficiency of metal ion removal with the sample being treating. Perhaps doing a specific assay for the metal ions would help quantitate the metal content of the buffers before and after treatment. A batch overnight treatment of the solutions would remove metal ions more efficiently than a one hour treatment, particularly in the ethanol solutions.

      Note, ethanol will shrink the resin beads and decrease the porosity of the resin, and this would decrease the efficiency of the exchange, particularly for larger metallic ions. Thus a solution of 40% ethanol will require a longer incubation time to remove all of the metal ions. Increasing the Chelex treatment time would allow more time for ion exchange to occur.

      Stryrene divinylbenzene and iminodiacetic acid (the functional group) can leach from the resin, and this would be increased with the higher concentration of ethanol. The recommendation is to wash the resin with 100% ethanol and then equilibrate in aqueous solution immediately before using the resin. If the failure to aggregate is due to something leaching from the resin, this experiment should eliminate this possibility.

      Also, the carboxyl groups on the resin have a very high selectivity for hydrogen ions, and will exchange hydrogen ions from water, resulting in an increased pH. There is no solution for this except to try equilibrating the resin using the protocol in the instruction manual (this doesn't work very well) or to adjust the pH of the buffer after the Chelex treatment.. The functional group will lose its polarity and metals won't exchange onto the resin. Studies have indicated the resin is still functional in 20% methanol and ethanol.

      Organic solvents such as DMSO or DMF might also affect the selectivity of the resin slightly for divalent cations and would reduce the interaction between small hydrophobic molecules and the resin matrix. The resin may also swell upon exposure to the chemicals, but it won't melt or dissolve.

      Helpful?

  4. Can this be used to remove calcium from FBS for Keratinocyte culture ?

    1 answer
    1. This product has been used to remove calcium from FBS. However, the application has not been validated internally.

      Helpful?

  5. How is the Chelex 100 resin used and how is it washed back? Can you please provide a manual of its usage?

    1 answer
    1. Please see the link below to review the washing steps and usage instructions provided in the product datasheet.
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/200/928/c7901pis.pdf

      Helpful?

  6. What is the grade (analytical; technical; molecular biology, or... ) of this reagent?

    1 answer
    1. This product is not assigned a specific grade or tested for a specific application.

      Helpful?

  7. What is the particle size of the resin in Product C7901, Chelex 100?

    1 answer
    1. The particle size for this resin is 45-165 microns. The mean particle size is 90 microns.

      Helpful?

  8. My Chelex 100 (Product C7901) in my column dried out.  Can I still use it?

    1 answer
    1. The resin may be rehydrated and used, as long as it remains white.  If the color of the re-swollen resin is yellow, do not use it.

      Helpful?

  9. What solvent should I use to swell the Product C7901, Chelex 100 at the beginning?

    1 answer
    1. We recommend using a good grade of water (deionized or distilled).

      Helpful?

  10. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

1–10 of 11 Questions  

Reviews

No rating value

Active Filters