Pular para o conteúdo
Merck

Pular para

P3C030D00

Cassete Pellicon® 3 com membrana Ultracel®

filtration area 88 cm2, NMWCO 30 kDa, holdup volume, 3.6 mL (in feed channel)

Sinônimo(s):

Pellicon® 3 Cassette with Ultracel® 30 kDa Membrane, D screen, 88 cm2

Faça login para ver os preços organizacionais e de contrato.

Selecione um tamanho

Alterar visualização
Tamanho/SKUDisponibilidadePreço

Sobre este item

UNSPSC Code:
41104903
NACRES:
NB.24
eCl@ss:
32031602
Preço e disponibilidade não estão disponíveis no momento.
Assistência Técnica
Precisa de ajuda? Nossa equipe de cientistas experientes está à sua disposição.
Estamos aqui para ajudar


Quality Segment

material

TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene cap (for end), polypropylene screen

product line

Pellicon®

feature

holdup volume 3.6 mL (in feed channel)

manufacturer/tradename

Pellicon®

parameter

2.75 bar max. inlet pressure (40 psi) at 50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration), tangential flow filtration (TFF): suitable

H

0.8 cm (0.33 in.)

L

20.6 cm (8.1 in.)

W

5.6 cm (2.2 in.)

filtration area

88 cm2

membrane area

88 cm2

gravimetric extractables

≤1500 mg/m2

matrix

Ultracel® (Membrane)

pore size

30 kDa NMWCO

pH

2-13

shipped in

ambient

General description

Pellicon® 3 filtration devices are advanced, high-performance cassettes ideal for today’s higher titer therapeutic antibodies as well as the more demanding filtration processes that require higher operating pressures, temperatures and caustic cleaning regimes.

The Pellicon® 3 Cassette with Ultracel® Membrane is designed for the filtration of therapeutic proteins (such as monoclonal antibodies) and recombinant and non-recombinant proteins.

This P3C030D00 Pellicon® 3 ultrafiltration device features a pore size of 30 kDa NMWCO, a filtration area of 88 cm2, a PLCTK membrane, and dimensions measuring 3.8 cm (H) x 17.8 cm (W) x 20.6 cm (L).

Features and Benefits

  • Rugged & reliable – ideally suited for today′s more demanding filtration processes
  • High performance – produces excellent resolution, yields and back-pressure resistance
  • Optimum product recovery – thanks to proven membrane technology
  • Void-free technology – leading-edge membranes resolve virtually any separation challenge
  • Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
  • Automated manufacturing – delivers unbeatable performance, consistency and reliability
  • Easy installation & care – simple to install and maintain

Analysis Note

Gravimetric Extractables: after 24 hours in water at controlled room temperature

Other Notes

These products are manufactured in a facility which adheres to Good Manufacturing Practices.

Legal Information

Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

Comparar Itens Semelhantes

Ver Comparação Total

Mostrar diferenças

1 of 1

Este Item
P3C030C00P3C003C10P3C003C05
description

filtration area 88 cm2, NMWCO 30 kDa, holdup volume, 3.6 mL (in feed channel)

description

filtration area 88 cm2, NMWCO 30 kDa, holdup volume, 1.5 mL (in feed channel)

description

filtration area 1.14 m2, NMWCO 3 kDa, Holdup volume 170 mL

description

filtration area 0.57 m2, NMWCO 3 kDa

pore size

30 kDa NMWCO

pore size

30 kDa NMWCO

pore size

3 kDa NMWCO

pore size

3 kDa NMWCO

technique(s)

protein purification: suitable (concentration), analytical sample preparation: suitable, buffer exchange: suitable

technique(s)

buffer exchange: suitable, analytical sample preparation: suitable, protein purification: suitable (concentration)

technique(s)

protein purification: suitable (concentration), analytical sample preparation: suitable, buffer exchange: suitable

technique(s)

protein purification: suitable (concentration), analytical sample preparation: suitable, buffer exchange: suitable

filtration area

88 cm2

filtration area

88 cm2

filtration area

1.14 m2

filtration area

0.57 m2

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

matrix

Ultracel® (Membrane)

material

polypropylene cap (for end), TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene screen

material

polypropylene screen, TPE seal, polypropylene cap (for end), composite regenerated cellulose (CRC) membrane

material

composite regenerated cellulose (CRC) , TPE seal, polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated)

material

stainless steel cap (for end; polypropylene-encapsulated), composite regenerated cellulose (CRC) , TPE seal, polypropylene screen

parameter

2.75 bar max. inlet pressure (40 psi) at 50 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 80 psi max. transmembrane pressure at 4-40 °C, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 4-6 L/min-m2 recirculation rate

parameter

6.9 bar max. inlet pressure (100 psi), 4-6 L/min-m2 recirculation rate, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 40 psi max. transmembrane pressure at 4-50 °C, 80 psi max. transmembrane pressure at 4-40 °C, 2.75 bar max. inlet pressure (40 psi) at 50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 5.5 bar max. inlet pressure (80 psi) at 40 °C

parameter

40 psi max. transmembrane pressure at 4-50 °C, 4-6 L/min-m2 recirculation rate, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours)

parameter

40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 80 psi max. transmembrane pressure at 4-40 °C


Still not finding the right product?


Classe de armazenamento

10 - Combustible liquids

O que está acontecendo?

WGK 2



Mantenha-se em conformidade com a GMP usando o programa Emprove®

Acelere a qualificação, mantenha a conformidade e economize tempo com Emprove® Dossiers.

Baixar Dossiers

Nota: você será levado ao EmproveSuite.com. Seu nome de usuário e senha são separados do SigmaAldrich.com e podem ser diferentes.

Registre-se gratuitamente e acesse Emprove® Dossiers em poucos minutos. Faça upgrade de seu plano de assinatura para desbloquear conteúdo avançado e personalizado no Emprove® Suite

Não está encontrando o que está procurando? Visite a página de ajuda do programa Emprove®.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Dificuldade em encontrar seu produto ou número de lote?

Os números dos produtos são combinados com os tamanhos/quantidades da embalagem quando exibidos no site (exemplo: T1503-25G). Por favor, certifique-se você insere APENAS o número do produto no campo Número do produto (exemplo: T1503).

Exemplo:

T1503
Número do produto
-
25G
Tamanho/quantidade da embalagem

Exemplos adicionais:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

inserir como 1.000309185)

Está a ter problemas? Não hesite em contactar-nos Assistência Técnica para obter assistência



Questions

Reviews

No rating value