Sélectionner une taille de conditionnement
| Taille/Référence | Disponibilité | Prix |
|---|
A propos de cet article
Quality Segment
material
TPE seal, composite regenerated cellulose (CRC) membrane, polypropylene , polypropylene cap (for end), polypropylene screen
product line
Pellicon®
feature
holdup volume 3.6 mL (in feed channel)
manufacturer/tradename
Pellicon®
parameter
2.75 bar max. inlet pressure (40 psi) at 50 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C
technique(s)
analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration), tangential flow filtration (TFF): suitable
H
0.8 cm (0.33 in.)
L
20.6 cm (8.1 in.)
W
5.6 cm (2.2 in.)
filtration area
88 cm2
membrane area
88 cm2
gravimetric extractables
≤1500 mg/m2
matrix
Ultracel® (Membrane)
pore size
30 kDa NMWCO
pH
2-13
shipped in
ambient
General description
La cassette Pellicon® 3 avec membrane Ultracel® est conçue pour la filtration de protéines thérapeutiques (telles que les anticorps monoclonaux) et de protéines recombinantes et non recombinantes.
Le dispositif d'ultrafiltration Pellicon® 3 P3C030D00 présente un seuil de coupure nominal (NMWCO) de 30 kDa, une surface de filtration de 88 cm2, une membrane PLCTK et des dimensions de 3,8 cm (H) × 17,8 cm (l) × 20,6 cm (L).
Features and Benefits
- Robuste et fiable – parfaitement adapté aux procédés de filtration plus exigeants d'aujourd'hui
- Haute performance – produit des niveaux excellents de résolution, de rendement et de résistance à la contre-pression
- Récupération optimale du produit grâce à une technologie membranaire qui a fait ses preuves
- Technologie à matrice dense – les membranes à la pointe de la technologie résolvent pratiquement tous les problèmes de séparation
- Adhérence supérieure sans défaut – Ultracel® utilise des membranes composites coulées sur un substrat microporeux
- Fabrication automatisée – offre des performances, une cohérence et une fiabilité inégalables
- Entretien et installation faciles – simple à installer et à entretenir
Analysis Note
Other Notes
Legal Information
1 of 1
Cet article | |||
|---|---|---|---|
| description filtration area 88 cm2, NMWCO 30 kDa, holdup volume, 3.6 mL (in feed channel) | description filtration area 88 cm2, NMWCO 30 kDa, holdup volume, 1.5 mL (in feed channel) | description filtration area 1.14 m2, NMWCO 3 kDa, Holdup volume 170 mL | description filtration area 0.57 m2, NMWCO 3 kDa |
| pore size 30 kDa NMWCO | pore size 30 kDa NMWCO | pore size 3 kDa NMWCO | pore size 3 kDa NMWCO |
| technique(s) buffer exchange: suitable, protein purification: suitable (concentration), analytical sample preparation: suitable | technique(s) analytical sample preparation: suitable, protein purification: suitable (concentration), buffer exchange: suitable | technique(s) buffer exchange: suitable, analytical sample preparation: suitable, protein purification: suitable (concentration) | technique(s) buffer exchange: suitable, analytical sample preparation: suitable, protein purification: suitable (concentration) |
| filtration area 88 cm2 | filtration area 88 cm2 | filtration area 1.14 m2 | filtration area 0.57 m2 |
| matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) |
| material composite regenerated cellulose (CRC) membrane, TPE seal, polypropylene , polypropylene cap (for end), polypropylene screen | material TPE seal, polypropylene screen, composite regenerated cellulose (CRC) membrane, polypropylene cap (for end) | material polypropylene screen, TPE seal, stainless steel cap (for end; polypropylene-encapsulated), composite regenerated cellulose (CRC) | material stainless steel cap (for end; polypropylene-encapsulated), TPE seal, composite regenerated cellulose (CRC) , polypropylene screen |
| parameter 80 psi max. transmembrane pressure at 4-40 °C, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 2.75 bar max. inlet pressure (40 psi) at 50 °C, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 4-6 L/min-m2 recirculation rate, 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 5.5 bar max. transmembrane pressure (80 psig) at 30 °C | parameter 2.75 bar max. inlet pressure (40 psi) at 50 °C, 4-6 L/min-m2 recirculation rate, 5.5 bar max. inlet pressure (80 psi) at 40 °C, 80 psi max. transmembrane pressure at 4-40 °C, 6.9 bar max. inlet pressure (100 psi), 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C | parameter 6.9 bar max. inlet pressure (100 psi), 40 psi max. transmembrane pressure at 4-50 °C, 4-6 L/min-m2 recirculation rate, 80 psi max. transmembrane pressure at 4-40 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours) | parameter 6.9 bar max. inlet pressure (100 psi), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 80 psi max. transmembrane pressure at 4-40 °C, 30 psi max. reverse press. exposure at 25 °C (for 24 hours) |
Still not finding the right product?
Explore all of our products under Cassette Pellicon® 3 à membrane Ultracel®
Classe de stockage
10 - Combustible liquids
Que se passe-t-il ?
WGK 2
Listes réglementaires
Les listes réglementaires sont principalement fournies pour les produits chimiques. Seules des informations limitées peuvent être fournies ici pour les produits non chimiques. L'absence d'indication signifie qu'aucun des composants n'est répertorié. Il incombe à l'utilisateur de s'assurer de l'utilisation sûre et légale du produit.
64-19-7
Restez en conformité avec les BPF grâce au programme Emprove®.
Accélérer la qualification, maintenir la conformité et gagner du temps avec Emprove® Dossiers.
Note: you will be brought to EmproveSuite.com. Your username and password are separate from SigmaAldrich.com and may differ.
Inscrivez-vous gratuitement et accédez à Emprove® Dossiers en quelques minutes. Mettez votre abonnement à niveau pour débloquer un contenu avancé et personnalisé dans la Emprove® Suite
Vous ne trouvez pas ce que vous cherchez ? Visitez la page d'aide du programme Emprove®..
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Vous avez des difficultés à trouver la référence de votre produit ou son numéro de lot ?
Comment trouver le numéro de produit
Les références de produits sont combinées avec des tailles de conditionnement/quantités lorsqu'elles figurent sur le site Internet (exemple : T1503-25G). Assurez-vous de ne saisir QUE la référence du produit dans le champ Référence produit (exemple: T1503).
Exemple :
Autres exemples :
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
entrer en tant que 1.000309185)
Vous rencontrez des problèmes ? N'hésitez pas à contacter Service technique pour obtenir une assistance


