A propos de cet article
form
solution
usage
sufficient for ≤2,500 tests (11644807001), sufficient for ≤800 tests (05015944001)
packaging
bottle of 25 mL (11644807001), bottle of 8 mL (05015944001)
manufacturer/tradename
Roche
storage condition
protect from light
technique(s)
protein quantification: suitable
optimum pH
8.0(for physiological conditions our product is buffered pH 7.3)
λmax
440-480 nm
application(s)
cell analysis
detection
detection method
colorimetric
storage temp.
−20°C
General description
Ready-to-use solution, containing WST-1 and an electron coupling reagent.
Application
Biochem/physiol Actions
Cells grown in a 96-well tissue culture plate are incubated with the WST-1 reagent for 0.5 - 4 hours. After this incubation period, the formazan dye formed is quantitated with a scanning multi-well spectrophotometer (ELISA reader). The measured absorbance directly correlates to the number of viable cells.
Cell proliferation and viability assays are of particular importance for routine applications in cell biology. Tetrazolium salts (e.g., MTT, XTT, WST-1) are particularly useful for this type of analysis. Tetrazolium salts are cleaved to formazan by the succinate-tetrazolium reductase system (EC 1.3.99.1) which belongs to the respiratory chain of the mitochondria, and is only active in metabolically intact cells.
Features and Benefits
- Pratique : Benefit from a ready-to-use reagent.
- Eliminate radioactive isotopes, washing steps, and additional reagents.
- Précis : The absorbance obtained strongly correlates to the cell number.
- Sensible Detect low cell numbers.
- Rapides : Process a large number of samples using a multi-well ELISA reader.
Preparation Note
μ
μμ
When precipitates or turbidity are observed upon thawing, warm up the solution to 37 °C for 2 to 10 minutes and agitate to dissolve the precipitates.Centrifugation is not recommended because the working concentration would decrease. After being dissolved, the WST-1 reagent can be used without any limitations.
However please note that the solution may become viscous.
Other Notes
1 of 1
Cet article | |||
|---|---|---|---|
| description suitable for protein quantification, suitable for cell analysis, detection, solution | description ≥90% (HPLC) | description ≥97% (HPLC) | description - |
| technique(s) protein quantification: suitable | technique(s) - | technique(s) - | technique(s) - |
| detection method colorimetric | detection method - | detection method - | detection method - |
| application(s) cell analysis | application(s) cell analysis | application(s) - | application(s) - |
| packaging bottle of 25 mL (11644807001), bottle of 8 mL (05015944001) | packaging - | packaging - | packaging - |
| manufacturer/tradename Roche | manufacturer/tradename - | manufacturer/tradename - | manufacturer/tradename - |
| storage condition protect from light | storage condition - | storage condition - | storage condition - |
Classe de stockage
12 - Non Combustible Liquids
WGK
nwg
Point d'éclair (°F)
No data available
Point d'éclair (°C)
No data available