Passa al contenuto
Merck
  • Novel unbreakable solid-phase microextraction fibers on stainless steel wire and application for the determination of oxadiargyl in environmental and agricultural samples in combination with gas chromatography-mass spectrometry.

Novel unbreakable solid-phase microextraction fibers on stainless steel wire and application for the determination of oxadiargyl in environmental and agricultural samples in combination with gas chromatography-mass spectrometry.

Talanta (2014-07-26)
Ali Es-Haghi, Masoud Baghernejad, Habib Bagheri
ABSTRACT

Sol-gel based solid-phase microextraction fibers supported by a stainless steel wire were fabricated and employed for GC-MS determination of oxadiargyl in real samples. The fibers were based on four compounds with different polarity: polar and non-polar (end-capped) poly(dimethylsiloxane) (PDMS), polyethylene glycol (PEG), and poly(ethylene-propyleneglycol)-monobutyl ether (UCON). For this purpose, the surface of the stainless steel was initially modified by (3-mercaptopropyl) trimethoxysilane. The results of the modification procedure were evaluated by cyclic voltammetry and energy dispersive X-ray (EDX) spectroscopy. After the modification, four different sol-gel based SPME fibers with different values of polarity, polar and non-polar PDMS, PEG, and UCON have been prepared and investigated. They are supposed to be employed to determinate oxadiargyl in agricultural and environmental samples prior to gas chromatography-mass spectrometry analysis. Most important parameters that affect the extraction efficiency were also optimized. Under optimized conditions, the proposed method was found to be linear for the concentrations ranging from 100 ng L(-1) to 2 mg L(-1) with R(2)=0.997. Limit of detection (LOD) of 40 ng L(-1) and relative standard deviation of less than 10% were obtained. Relative recovery in environmental and agricultural samples was in the range of 73-96%.

MATERIALI
Numero di prodotto
Marchio
Descrizione del prodotto

Sigma-Aldrich
Metanolo, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Acetone, ACS reagent, ≥99.5%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Diclorometano, suitable for HPLC, ≥99.8%, contains amylene as stabilizer
Sigma-Aldrich
Acetone, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Diclorometano, contains 40-150 ppm amylene as stabilizer, ACS reagent, ≥99.5%
Sigma-Aldrich
Sodio idrossido, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
Acetone, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Sodio idrossido, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
Diclorometano, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Sigma-Aldrich
Metanolo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Idrossido di sodio, 50% in H2O
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, meets USP testing specifications
Sigma-Aldrich
Esano, ReagentPlus®, ≥99%
Sigma-Aldrich
Esano, suitable for HPLC, ≥95%
Sigma-Aldrich
Idrossido di sodio, BioUltra, Molecular Biology, 10 M in H2O
Sigma-Aldrich
Ammoniaca, 7 N in methanol
Sigma-Aldrich
Ethyl alcohol, Pure 190 proof, for molecular biology
Sigma-Aldrich
Idrossido di sodio, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Esano, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
Sodio idrossido, BioXtra, ≥98% (acidimetric), pellets (anhydrous)
Sigma-Aldrich
Sodio idrossido, puriss., meets analytical specification of Ph. Eur., BP, NF, E524, 98-100.5%, pellets
Sigma-Aldrich
Metanolo, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Metanolo, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Sodio idrossido, reagent grade, 97%, powder
Sigma-Aldrich
Diclorometano, ACS reagent, ≥99.5%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Metanolo, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Esano, Laboratory Reagent, ≥95%
Sigma-Aldrich
Etanolo, BioUltra, Molecular Biology, ≥99.8%, (absolute alcohol, without additive, A15 o1)