Przejdź do zawartości
Merck

A novel flow-based assay reveals discrepancies in ADAMTS-13 inhibitor assessment as compared with a conventional clinical static assay.

Journal of thrombosis and haemostasis : JTH (2014-07-22)
R Grillberger, B Gruber, S Skalicky, G Schrenk, P Knöbl, B Plaimauer, P L Turecek, F Scheiflinger, H Rottensteiner
ABSTRAKT

Several static Bethesda-type assays are routinely used to determine ADAMTS-13-neutralizing autoantibodies in acquired thrombotic thrombocytopenic purpura (TTP), but the inhibitory activity of these antibodies has not been thoroughly evaluated under the more physiologic condition of flow. We investigated whether ADAMTS-13 inhibitor assessment with the FRETS-VWF73 assay is predictive for evaluation under flow. Anti-ADAMTS-13 autoantibodies were purified from patients with acquired TTP by chromatography involving an ADAMTS-13 affinity matrix and/or protein G. ADAMTS-13 activity was measured with the FRETS-VWF73 assay and a novel flow assay determining the ADAMTS-13-mediated decrease in platelet aggregate surface coverage, caused by perfusion of a suspension containing platelets, erythrocytes and von Willebrand factor (VWF) over a surface coated with extracellular matrix components. The neutralizing activities of ADAMTS-13 inhibitors were compared under static conditions and under flow by use of the two assays. The suitability of the flow-based ADAMTS-13 activity assay for quantification of ADAMTS-13 inhibitors could be demonstrated by reversibility of the ADAMTS-13-dependent decrease in surface coverage upon addition of goat ADAMTS-13 antiserum. Testing the neutralizing activity of purified autoantibodies from six patients in the flow assay according to their FRETS-VWF73-based inhibitor titers gave rise to vastly different inhibitory effects, indicating a discrepancy in inhibitor assessment between static and flow conditions. Anti-ADAMTS-13 autoantibodies may show inhibitory properties in vivo that are not consistent with the ADAMTS-13 inhibitor levels determined in routine static assays, possibly because certain epitopes are selectively exposed under shear. Consequently, the course of disease and treatment efficacy may vary among TTP patients, despite common inhibitor titers.

MATERIAŁY
Numer produktu
Marka
Opis produktu

Supelco
Aspirin (Acetyl Salicylic Acid), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Aspirin, meets USP testing specifications
USP
Aspiryna, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Sodium chloride solution, 0.85%
Sigma-Aldrich
Sodium chloride, 99.999% trace metals basis
Sigma-Aldrich
Sodium chloride, random crystals, 99.9% trace metals basis
Sigma-Aldrich
Sodium chloride-35Cl, 99 atom % 35Cl
Sigma-Aldrich
Sodium sulfate, ≥99.99% trace metals basis
Sigma-Aldrich
Sodium sulfate, BioUltra, anhydrous, ≥99.0% (T)
Sigma-Aldrich
Sodium sulfate, tested according to Ph. Eur., anhydrous
Sigma-Aldrich
Sodium chloride, AnhydroBeads, −10 mesh, 99.999% trace metals basis
Sigma-Aldrich
Acetylsalicylic acid, ≥99.0%
Sigma-Aldrich
Sodium chloride, Molecular Biology, DNase, RNase, and protease, none detected, ≥99% (titration)
Sigma-Aldrich
Sodium chloride, meets analytical specification of Ph. Eur., BP, USP, 99.0-100.5%
Sigma-Aldrich
Sodium chloride, tablet
Sigma-Aldrich
Sodium chloride, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%
Sigma-Aldrich
Sodium sulfate, BioXtra, ≥99.0%
Sigma-Aldrich
Sodium sulfate, ≥99.0%, suitable for plant cell culture
Sigma-Aldrich
Sodium chloride, BioXtra, ≥99.5% (AT)
Sigma-Aldrich
Sodium chloride solution, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
Sodium chloride solution, 5 M
Sigma-Aldrich
Acetylsalicylic acid, analytical standard
SAFC
Sodium chloride solution, 5 M
Sigma-Aldrich
Sodium chloride, BioUltra, Molecular Biology, ≥99.5% (AT)
Supelco
Sodium chloride, reference material for titrimetry, certified by BAM, >99.5%
Sigma-Aldrich
Sodium chloride, tested according to Ph. Eur.
Sigma-Aldrich
Sodium chloride solution, BioUltra, Molecular Biology, ~5 M in H2O
Sigma-Aldrich
Bovine Serum Albumin, heat shock fraction, protease free, pH 7, ≥98%
Sigma-Aldrich
Sodium chloride, BioPerformance Certified, ≥99% (titration), suitable for insect cell culture, suitable for plant cell culture
Sigma-Aldrich
Sodium sulfate, anhydrous, free-flowing, Redi-Dri, ACS reagent, ≥99%