Przejdź do zawartości
Merck

Nanocarriers and the delivered drug: effect interference due to intravenous administration.

European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences (2014-06-26)
Maria A Vlasova, Jussi Rytkönen, Joakim Riikonen, Olga S Tarasova, Juha Mönkäre, Miia Kovalainen, Ale Närvänen, Jarno Salonen, Karl-Heinz Herzig, Vesa-Pekka Lehto, Kristiina Järvinen
ABSTRAKT

Intravenously administered nanocarriers are widely studied to improve the delivery of various therapeutic agents. However, recent in vivo studies have demonstrated that intravenously administered nanocarriers that do not contain any drug may affect cardiovascular function. Here we provide an example where the drug and the nanocarrier both affect the same cardiovascular parameters following intravenous administration. The peptide ghrelin antagonist (GhA) increases arterial pressure, while thermally hydrocarbonized porous silicon nanoparticles (THCPSi) transiently decrease it, as assessed with radiotelemetry in conscious rats. As a result, intravenous administration of GhA-loaded THCPSi nanoparticles partially antagonized GhA activity: arterial pressure was not increased. When the cardiovascular effects of GhA were blocked with atenolol pretreatment, GhA-loaded nanoparticles reduced arterial pressure to similar extent as drug-free nanoparticles. These data indicate that the biological activity of a drug delivered within a nanocarrier may be obscured by the biological responses induced by the nanocarrier itself.

MATERIAŁY
Numer produktu
Marka
Opis produktu

Sigma-Aldrich
HEPES, anhydrous, free-flowing, Redi-Dri, ≥99.5%
Supelco
HEPES, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Sodium Metabisulfite, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Hydrofluoric acid, ACS reagent, 48%
Sigma-Aldrich
Sodium metabisulfite, ReagentPlus®, ≥99%
Sigma-Aldrich
Potassium iodide, ACS reagent, ≥99.0%
Sigma-Aldrich
Potassium iodide, anhydrous, free-flowing, Redi-Dri, ReagentPlus®, 99%
Sigma-Aldrich
Sodium metabisulfite, reagent grade, 97%
Sigma-Aldrich
Potassium iodide, ReagentPlus®, 99%
Sigma-Aldrich
Sodium metabisulfite, puriss., meets analytical specification of Ph. Eur., BP, NF, FCC, E223, dry, 97-100.5%
Sigma-Aldrich
Hydrofluoric acid, 48 wt. % in H2O, ≥99.99% trace metals basis
Supelco
Potassium Iodide, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Atenolol, ≥98% (TLC), powder
Sigma-Aldrich
HEPES, BioXtra, suitable for mouse embryo cell culture, ≥99.5% (titration)
Sigma-Aldrich
HEPES, ≥99.5% (titration)
Sigma-Aldrich
Potassium iodide, BioXtra, ≥99.0%
Sigma-Aldrich
Potassium iodide, suitable for plant cell culture
Sigma-Aldrich
HEPES, BioXtra, pH 5.0-6.5 (1 M in H2O), ≥99.5% (titration)
Sigma-Aldrich
HEPES, BioPerformance Certified, ≥99.5% (titration), suitable for cell culture
Sigma-Aldrich
Potassium iodide, AnhydroBeads, −10 mesh, 99.998% trace metals basis
Sigma-Aldrich
Potassium iodide, BioUltra, ≥99.5% (AT)
Sigma-Aldrich
HEPES, BioUltra, Molecular Biology, ≥99.5% (T)
Supelco
Sodium metabisulfite, analytical standard
Sigma-Aldrich
Potassium iodide, anhydrous, free-flowing, Redi-Dri, ACS reagent, ≥99%
USP
Sodium metabisulfite, United States Pharmacopeia (USP) Reference Standard
Atenolol, European Pharmacopoeia (EP) Reference Standard
USP
Atenolol, United States Pharmacopeia (USP) Reference Standard
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Sodium metabisulfite, tested according to Ph. Eur.