Przejdź do zawartości
Merck
  • Development and validation of an HPTLC method for apigenin 7-O-glucoside in chamomile flowers and its application for fingerprint discrimination of chamomile-like materials.

Development and validation of an HPTLC method for apigenin 7-O-glucoside in chamomile flowers and its application for fingerprint discrimination of chamomile-like materials.

Journal of pharmaceutical and biomedical analysis (2015-01-13)
Etil Guzelmeric, Irena Vovk, Erdem Yesilada
ABSTRAKT

Brewed tea of chamomile flowers (Matricaria recutita L.) (Asteraceae) has been extensively consumed for centuries due to either its pleasant taste or medicinal purposes. On the other hand, the major problem is difficulty in distinguishing the genuine specimen when supplying chamomile through nature-picking. Consequently flowers of other Asteraceae members resembling to chamomile in appearance may frequently be practiced by lay people or marketed in spice shops or bazaars. Evidently detection of such adulterations plays a vital role in terms of public health to avoid risk of toxicity (i.e. pyrazolidin alkaloids) and ineffective treatments (lack or insufficient concentration of the active constituents). This work presents either development and validation of a high performance thin-layer chromatographic (HPTLC) method for apigenin 7-O-glucoside which is one of the active markers in chamomile flowers or its application for the fingerprint discrimination of chamomile-like materials i.e. Anthemis spp., Bellis spp., Chrysanthemum sp. and Tanacetum sp. gathered by local people assuming as chamomile. Separation was performed on the silica gel 60 NH2 F254s HPTLC plates using the developing solvent system of ethyl acetate-formic acid-acetic acid-water (30:1.5:1.5:3, v/v/v/v). The proposed HPTLC method may also be a leading guide for the quality assessment of chamomile tea products on the market.

MATERIAŁY
Numer produktu
Marka
Opis produktu

Sigma-Aldrich
Sodium hydroxide-16O solution, 20 wt. % in H216O, 99.9 atom % 16O
Sigma-Aldrich
Ethyl acetate, ≥99%, FCC, FG
Sigma-Aldrich
2-Butanone, FCC, FG
Supelco
L-Lysine monohydrochloride, Pharmaceutical Secondary Standard; Certified Reference Material
Millipore
Bifido Selective Supplement B, suitable for microbiology
Sigma-Aldrich
2-Propanol, electronic grade, 99.999% trace metals basis
Supelco
Luteolin, analytical standard
Supelco
Dichloromethane, Selectophore, ≥99.5%
Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Sigma-Aldrich
5,7-Dihydroxy-4-methylcoumarin, 98%
Sigma-Aldrich
Ethyl acetate, ReagentPlus®, ≥99.8%
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
2-Propanol, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%, poly coated bottles
Supelco
2-Butanone, analytical standard
Sigma-Aldrich
2-Propanol, BioUltra, Molecular Biology, ≥99.5% (GC)
Supelco
2-Propanol, analytical standard
Sigma-Aldrich
L-Lysine monohydrochloride, BioUltra, ≥99.5% (AT)
Sigma-Aldrich
Dichloromethane, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
L-Lysine monohydrochloride, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
2-Propanol, BioReagent, ≥99.5%, Molecular Biology
Sigma-Aldrich
2-Aminoethyl diphenylborinate, 97%
Sigma-Aldrich
Luteolin, ≥98% (TLC), powder
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, ≥97.5%
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, purum, ≥99.0% (TLC)
Supelco
Hexane, analytical standard
Supelco
Methylene Chloride, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
2-Propanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
L-Lysine monohydrochloride, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Supelco
Ethyl acetate, analytical standard