Skip to Content
MilliporeSigma
  • Dissolvable layered double hydroxide coated magnetic nanoparticles for extraction followed by high performance liquid chromatography for the determination of phenolic acids in fruit juices.

Dissolvable layered double hydroxide coated magnetic nanoparticles for extraction followed by high performance liquid chromatography for the determination of phenolic acids in fruit juices.

Journal of chromatography. A (2014-09-28)
Mohammad Saraji, Milad Ghani
ABSTRACT

A magnesium-aluminum layered double hydroxide coated on magnetic nanoparticles was synthesized and used as a sorbent to extract some phenolic acids including p-hydroxy benzoic acid, caffeic acid, syringic acid, p-coumaric acid and ferulic acid from fruit juices. After extraction, the elution step was performed through dissolving double hydroxide layers containing the analytes by changing the solution pH. The extracted phenolic acids were separated and quantified using high performance liquid chromatography-photodiode array detection. Experimental parameters such as sorbent amount, solution pH, desorption solvent volume and extraction time were studied and optimized. The linearity range of the method was between 2 and 500μgL(-1) with the determination coefficient (r(2)) higher than 0.991. Relative standard deviations for intra- and inter-day precision for the analytes at 100μgL(-1) were in the range of 4.3-9.2% and 4.9-8.6%, respectively. Batch-to-batch reproducibility at 100μgL(-1) concentration level was in the range of 7.8-11% (n=3). The limits of detection were between 0.44 and 1.3μgL(-1). Relative recoveries higher than 81% with RSDs in the range of 4.2-9.7% were obtained in the analysis of fruit juice samples.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Iron(II) chloride tetrahydrate, SAJ first grade, 98.0-102.0%
Sigma-Aldrich
trans-Ferulic acid, ≥99%
Supelco
4-Hydroxybenzoic acid, Pharmaceutical Secondary Standard; Certified Reference Material
Millipore
Bifido Selective Supplement B, suitable for microbiology
Sigma-Aldrich
Methanol solution, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Iron(II) chloride tetrahydrate, 99.99% trace metals basis
Sigma-Aldrich
trans-Ferulic acid, 99%
Supelco
trans-Ferulic acid, suitable for matrix substance for MALDI-MS, ≥99.0% (HPLC)
Sigma-Aldrich
Ammonium hydroxide solution, BioUltra, ~1 M NH3 in H2O (T)
Supelco
Caffeic acid, suitable for matrix substance for MALDI-MS, ≥99.0% (HPLC)
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, ≥97.5%
Sigma-Aldrich
Caffeic acid, ≥98.0% (HPLC)
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Supelco
trans-p-Coumaric acid, analytical standard
Sigma-Aldrich
Syringic acid, ≥95% (HPLC)
Sigma-Aldrich
4-Hydroxybenzoic acid, ReagentPlus®, ≥99%
Supelco
Syringic acid, analytical standard
Supelco
5α-Androstan-17β-ol-3-one, VETRANAL®, analytical standard
Supelco
trans-Ferulic acid, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Ferulic acid, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
4-Hydroxybenzoic acid, ReagentPlus®, 99%
Sigma-Aldrich
Ammonium hydroxide solution, puriss., meets analytical specification of Ph. Eur., 25-30% NH3 basis
Sigma-Aldrich
Ammonium hydroxide solution, puriss., 30-33% NH3 in H2O
Sigma-Aldrich
Iron(II) chloride tetrahydrate, ReagentPlus®, 98%
Sigma-Aldrich
Ammonium hydroxide solution, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Ammonium hydroxide solution, puriss. p.a. plus, ≥25% NH3 in H2O
Sigma-Aldrich
Ammonium hydroxide solution, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
Iron(II) chloride tetrahydrate, puriss. p.a., ≥99.0% (RT)
Sigma-Aldrich
Ammonium hydroxide solution, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis
USP
Glacial acetic acid, United States Pharmacopeia (USP) Reference Standard