Skip to Content
MilliporeSigma
  • Quantitative assessment of human serum transferrin receptor in breast cancer patients pre- and post-chemotherapy using peptide immunoaffinity enrichment coupled with targeted proteomics.

Quantitative assessment of human serum transferrin receptor in breast cancer patients pre- and post-chemotherapy using peptide immunoaffinity enrichment coupled with targeted proteomics.

Clinica chimica acta; international journal of clinical chemistry (2015-06-23)
Qingqing Xu, Mingchen Zhu, Ting Yang, Feifei Xu, Yuan Liu, Yun Chen
ABSTRACT

sTfR, a soluble form of transferrin receptor in serum, has been suggested as an indicator of bone marrow failure in breast cancer patients receiving chemotherapy. However, intensive chemotherapy could also cause a reduction of sTfR to a level below the LOQ of most assays. An advanced liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based targeted proteomics assay coupled with peptide immunoaffinity enrichment (SISCAPA) was developed and validated for monitoring sTfR. Tryptic peptide 681VEYHFLSPYVSPK693 was selected as a surrogate analyte for quantification. High-abundant proteins were first removed from serum, followed by SISCAPA that was effective in surrogate peptide enrichment and sensitivity enhancement. The resulting LOQ can achieve 100ng/ml (~10-fold increase). Then, sTfR levels in breast cancer patients pre- and post-chemotherapy, and healthy volunteers were accurately quantified as 1.77±0.53μg/ml, 0.98±0.26μg/ml and 1.66±0.50μg/ml, respectively, using a standard addition method. While there was no evidence for a difference between patients and healthy volunteers, differential levels of sTfR pre- and post-chemotherapy were obtained. Comparison between SISCAPA-targeted proteomics and ELISA indicated that the former approach provided a lower value of sTfR. SISCAPA-targeted proteomics may allow the quantification of low-abundant proteins in a more accurate manner.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Ultrapure Acetonitrile
SAFC
Iodoacetamide
Sigma-Aldrich
Acetonitrile, suitable for chromatography
Sigma-Aldrich
Acetonitrile, SAJ first grade, ≥99.0%
Sigma-Aldrich
Formic acid, JIS special grade, ≥98.0%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Trifluoroacetic acid, SAJ special grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 300
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 1000
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Supelco
Acetonitrile, HPLC grade, ≥99.93%
Sigma-Aldrich
Methanol solution, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Acetonitrile, ≥99.5%, ACS reagent
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Iodoacetamide, Single use vial of 56 mg
Sigma-Aldrich
Sodium dodecyl sulfate solution, BioUltra, 20% in H2O
Sigma-Aldrich
Sodium dodecyl sulfate solution, BioUltra, Molecular Biology, 10% in H2O
Sigma-Aldrich
Iodoacetamide, BioUltra
Sigma-Aldrich
Iodoacetamide, ≥99% (NMR), crystalline
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, ≥97.5%
Sigma-Aldrich
Indole-3-acetic acid sodium salt, suitable for plant cell culture, BioReagent, ≥98%
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, suitable for residue analysis, JIS 5000
Sigma-Aldrich
Sodium dodecyl sulfate, ≥99.0% (GC), dust-free pellets
Sigma-Aldrich
3-Indoleacetic acid, SAJ special grade, ≥98.5%
Sigma-Aldrich
Sodium dodecyl sulfate, ≥99.0%
Sigma-Aldrich
Acetic acid, SAJ first grade, ≥99.0%