跳轉至內容
Merck

KHVEG03HH3

Millipore Express® SHR with prefilter 0.5/0.1µm, Opticap® XL 3 Capsule

Fittings 9/16 in. HB/HB, Gamma Compatible

同義詞:

Millipore Express® SHRP,Opticap® XL囊式

登入 查看組織和合約定價

選擇尺寸

暫時無法取得訂價和供貨情況

關於此項目

分類程式碼代碼:
23151806

跳轉至

技術服務
需要援助?我們經驗豐富的科學家團隊隨時樂意為您提供支援。
讓我們為您提供幫助

產品名稱

Opticap 可γ辐照 XL 3 Millipore Express SHR 带预滤器 0.5/0.1 µm 9/16 in.HB/HB, inlet connection diam. 9/16 in., Opticap® XL 300, pore size 0.5/0.1 μm, cartridge nominal length 3 in. (7.5 cm)

材料

polyester support
polyethersulfone
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap (Gamma stable)
polysulfone
silicone seal

品質等級

法律遵循

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

無菌

non-sterile

滅菌相容性

gamma compatible

產品線

Opticap® XL 300

特點

gamma compatible
hydrophilic

製造商/商標名

Millipore Express®

參數

≤7.3 mL/min air diffusion at 3.45 bar (50 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure

技術

sterile filtration: suitable

長度

17.3 cm (6.8 in.)

寬度

4.2 in.

柱標稱長度

3 in. (7.5 cm)

直徑

12.4 cm (4.12 in.)

過濾面積

0.13 m2

入口接頭直徑

9/16 in.

入口到出口寬度

17.3 cm (6.8 in.)

出口接頭直徑

9/16 in.

雜質

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

基質

Millipore Express® SHR (w/Prefilter)

pore size

0.5/0.1 μm pore size

起泡點

≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water at 23 °C

接頭

1/4 in. drain/vent hose barb (with double O-ring Seal)
inlet hose barb
outlet hose barb
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)

比較類似項目

查看完整比較

Show Differences

1 of 4

本產品
KHVEG03TT3KHVES03HH3KHVES03TH3
pore size

0.5/0.1 μm pore size

pore size

0.5/0.1 μm pore size

pore size

0.5/0.1 μm pore size

pore size

0.5/0.1 μm pore size

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

technique(s)

sterile filtration: suitable

filtration area

0.13 m2

filtration area

0.13 m2

filtration area

0.13 m2

filtration area

0.13 m2

product line

Opticap® XL 300

product line

Opticap® XL 3

product line

Opticap® XL 3

product line

Opticap® XL 3

manufacturer/tradename

Millipore Express®

manufacturer/tradename

Millipore Express®

manufacturer/tradename

Millipore Express®

manufacturer/tradename

Millipore Express®

material

polyester support, polypropylene (gamma-stable), polypropylene vent cap (Gamma stable), silicone seal, polyethersulfone , polysulfone , polypropylene housing

material

polyester support, polyethersulfone , polypropylene (gamma-stable), polypropylene housing, polypropylene vent cap (Gamma stable), polysulfone , silicone seal

material

polyester support, polyethersulfone , polypropylene (gamma-stable), polypropylene housing, polypropylene vent cap (Gamma stable), polysulfone , silicone seal

material

polyester support, polyethersulfone , polypropylene (gamma-stable), polypropylene housing, polypropylene vent cap (Gamma stable), polysulfone , silicone seal

一般說明

Device Configuration: 取样皿滤膜

包裝

Double Easy-Open bag

準備報告

Sterilization Method
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

分析報告

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
TOC/Conductivity
After sterilization and a controlled water flush of 5.5 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L

其他說明

Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

法律資訊

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

免責聲明

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

使用 Emprove® 計劃保持符合 GMP 規範

使用 Emprove® Dossiers 加快資格審核、維持合規性並節省時間。

下載 Dossiers

注意:您將被帶到 EmproveSuite.com。您的用戶名和密碼與 SigmaAldrich.com 是分開的,可能會有所不同

免費註冊並在數分鐘內存取 Emprove® Dossiers。 升級您的訂閱方案,解鎖 Emprove® Suite 中的進階和客製化內容。

找不到您要的內容?請造訪 Emprove® Program Help 頁面

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Questions

Reviews

No rating value

Active Filters

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務