P3C030D05
TPE seal
composite regenerated cellulose (CRC)
polypropylene screen
stainless steel cap (for end; polypropylene-encapsulated)
holdup volume 118 mL (in feed channel)
Pellicon®
30 psi max. reverse press. exposure at 25 °C (for 24 hours)
4-6 L/min-m2 recirculation rate
40 psi max. transmembrane pressure at 4-50 °C
6.9 bar max. inlet pressure (100 psi)
80 psi max. transmembrane pressure at 4-40 °C
analytical sample preparation: suitable
buffer exchange: suitable
protein purification: suitable (concentration)
2.6 cm (1.01 in.)
20.6 cm (8.1 in.)
17.8 cm (7 in.)
0.57 m2
0.57 m2
≤1500 mg/m2
Ultracel® (Membrane)
30 kDa NMWCO
2-13
Looking for similar products? Visit Product Comparison Guide
1 of 4
This Item | P3C030C05 | P3C030D01 | P3C010C05 |
---|---|---|---|
feature holdup volume 118 mL (in feed channel) | feature holdup volume 85 mL (in feed channel) | feature holdup volume 23 mL (in feed channel) | feature holdup volume 85 mL (in feed channel) |
parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C | parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C | parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C | parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C |
technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) | technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) | technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) | technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) |
filtration area 0.57 m2 | filtration area 0.57 m2 | filtration area 0.11 m2 | filtration area 0.57 m2 |
matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) |
10 - Combustible liquids
WGK 1
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.
How to Find the Product Number
Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).
Example:
Additional examples:
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
enter as 1.000309185)
Having trouble? Feel free to contact Technical Service for assistance.
How to Find a Lot/Batch Number for COA
Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.
For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').
For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').
For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.
In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service