Skip to Content
MilliporeSigma
  • Rapid screening of oleuropein from olive leaves using matrix solid-phase dispersion and high-performance liquid chromatography.

Rapid screening of oleuropein from olive leaves using matrix solid-phase dispersion and high-performance liquid chromatography.

Journal of AOAC International (2014-08-26)
Marzieh Rashidipour, Rouhollah Heydari, Alireza Feizbakhsh, Payman Hashemi
ABSTRACT

Matrix solid-phase dispersion (MSPD) methodology as a quick and easy extraction method has been developed to extract oleuropein from Olea europaea leaves. This method has been compared with conventional maceration and Soxhlet extraction (SOXE) methods. Variables affecting MSPD, such as the sorbent material, the ratio of sample to sorbent material, elution solvent, and volume of the elution solvent, have been fully evaluated and optimized. Oleuropein was successfully extracted by silica sorbent with 350 microL of dichloromethane-methanol (70 + 30, v/v) as the elution solvent. The calibration curve showed good linearity (r2 = 0.9985) and precision (RSD <4.5%) in the concentration range of 0.5-100 microg/mL for oleuropein. The LOD and LOQ were 0.14 and 0.5 microg/mL, respectively. The recoveries were in the range of 88.0-94.0% with RSD values ranging from 6.0 to 9.8%. The extraction yields obtained by the MSPD method were comparable with those obtained by the maceration and SOXE methods. The reported MSPD extraction method was revealed to be eco-friendly, simpler, and faster than conventional methods used to quantify oleuropein in O. europaea leaves.

MATERIALS
Product Number
Brand
Product Description

Supelco
L-Lysine monohydrochloride, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
Dichloromethane solution, contains 10 % (v/v) methanol
Supelco
L-Lysine monohydrochloride, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acetonitrile, suitable for residue analysis, JIS 5000
Sigma-Aldrich
Acetonitrile, suitable for chromatography
Sigma-Aldrich
Ethyl acetate, suitable for HPLC
Sigma-Aldrich
Hexane, suitable for residue analysis, JIS 5000
Sigma-Aldrich
Hexane, suitable for HPLC
Sigma-Aldrich
Hexane, JIS special grade, ≥96.0%
Sigma-Aldrich
Ethanol, ≥99.5%, suitable for HPLC
Sigma-Aldrich
Dichloromethane, JIS special grade, ≥99.0%
Sigma-Aldrich
Dichloromethane, SAJ first grade, ≥99.0%
Sigma-Aldrich
Ethanol, JIS 300, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Ethyl acetate, JIS 300, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Hexane, JIS 1000, ≥96.0%, suitable for residue analysis
Sigma-Aldrich
Ethanol, JIS 1000, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Ethyl acetate, JIS special grade, ≥99.5%
Sigma-Aldrich
Ethanol, ≥99.5%
Sigma-Aldrich
Ethanol, ≥99.5%, suitable for absorption spectrum analysis
Sigma-Aldrich
Ethyl acetate, SAJ first grade, ≥99.0%
Sigma-Aldrich
Oleuropein, ≥80% (HPLC)
Sigma-Aldrich
L-Lysine monohydrochloride, SAJ special grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 300
Sigma-Aldrich
Hexane, SAJ first grade, ≥95.0%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 1000
Sigma-Aldrich
Ethyl acetate, JIS 1000, ≥99.5%, suitable for residue analysis
Sigma-Aldrich
Ethanol, ≥99.5%, suitable for fluorescence
Sigma-Aldrich
Hexane, JIS 300, ≥96.0%, suitable for residue analysis
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Ethanol, ≥99.5%, SAJ super special grade