Skip to Content
MilliporeSigma
  • Determination of phthalate esters in environmental water by magnetic Zeolitic Imidazolate Framework-8 solid-phase extraction coupled with high-performance liquid chromatography.

Determination of phthalate esters in environmental water by magnetic Zeolitic Imidazolate Framework-8 solid-phase extraction coupled with high-performance liquid chromatography.

Journal of chromatography. A (2015-08-01)
Xiaomei Liu, Zhiwei Sun, Guang Chen, Wanwan Zhang, Yiping Cai, Rongmei Kong, Xiaoyan Wang, Yourui Suo, Jinmao You
ABSTRACT

In this study, the magnetic Zeolitic Imidazolate Framework-8 (ZIF-8) microspheres were successfully synthesized and applied as an effective sorbent for preconcentration of several typical phthalate esters (PAEs) from environmental water samples. Firstly, the solvothermal treatment method was used for preparation of Fe3O4 nanoparticles. Then, mercaptoacetic acid (MAA) was served as the functionalized chemical to modify Fe3O4 nanoparticles. The Fe3O4@ZIF-8 core-shell microspheres were synthesized through coating the MAA-capped Fe3O4 nanoparticles with ZIF-8. By coupling magnetic solid-phase extraction (MSPE) with high-performance liquid chromatography (HPLC), a reliable, sensitive and cost-effective method for simultaneous determination of five main PAEs including dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), benzyl butyl phthalate (BBP), and dioctyl phthalate (DOP) was developed. Good linearity was observed in the range of 1.0-100.0μg/L. The limits of detection (S/N=3) and limits of quantification (S/N=10) were in the range of 0.08-0.24 and 0.3-0.8μg/L, respectively. The relative standard deviations were less than 5.5% and the accuracies of the method for the PAEs were in the range from 85.6% to 103.6%. Finally, the Fe3O4@ZIF-8 was successfully applied for rapid extraction of trace amounts of PAEs in environmental water samples.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Sodium phosphate dibasic dodecahydrate, SAJ first grade, ≥98.0
Sigma-Aldrich
Sodium phosphate dibasic dodecahydrate, JIS special grade, ≥99.0%
Sigma-Aldrich
Toluene, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, SAJ first grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 300
Sigma-Aldrich
Toluene, JIS 300, suitable for residue analysis, ≥99.8%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 1000
Sigma-Aldrich
Toluene, JIS 1000, suitable for residue analysis, ≥99.8%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Acetonitrile, suitable for chromatography
Sigma-Aldrich
Acetonitrile, suitable for residue analysis, JIS 5000
Supelco
Acetonitrile, HPLC grade, ≥99.93%
Sigma-Aldrich
Diethyl pyrocarbonate, 96% (NT)
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Diethyl phthalate, SAJ special grade, ≥98.0%
Sigma-Aldrich
Toluene, SAJ first grade, ≥99.0%
Sigma-Aldrich
Diethyl pyrocarbonate, 96% (NT)
Sigma-Aldrich
Methanol solution, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Toluene, anhydrous, 99.8%
Supelco
Toluene, HPLC grade, 99.8%
Sigma-Aldrich
Diethyl phthalate, ≥99%
Sigma-Aldrich
Sodium phosphate dibasic dodecahydrate, BioXtra, ≥99.0% (T)
Sigma-Aldrich
Acetonitrile, ≥99.5%, ACS reagent
Sigma-Aldrich
Diethyl phthalate, 99.5%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Diethyl pyrocarbonate, 96% (NT)
Sigma-Aldrich
DBP, 98% (HPLC)
Sigma-Aldrich
Toluene, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Di-n-octyl phthalate, ≥98.0% (GC)