Skip to Content
MilliporeSigma

Skip To

54362

ICP solvent

for inorganic trace analysis, ≥99.9995% (metals basis)

Synonym(s):

Hydrotreated light distillate (petroleum)

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
1 L

Available to ship TODAYfromMILWAUKEE

$110.00

About This Item

CAS Number:
MDL number:
EC Number:
265-149-8
NACRES:
NA.24
UNSPSC Code:
12352200

$110.00


Available to ship TODAYDetails


​
Request a Custom Order
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Segment

assay

≥99.9995% (metals basis)

technique(s)

AAS: suitable, ICP: suitable

bp

200-250 °C (lit.)

mp

-58 °C (lit.)

density

0.810-0.838 g/mL at 20 °C

anion traces

phosphate (PO43-): ≤1 mg/kg, sulfate (SO42-): ≤5 mg/kg

cation traces

Ag: ≤1 μg/kg, Al: ≤1 μg/kg, As: ≤1 μg/kg, Au: ≤1 μg/kg, Ba: ≤0.5 μg/kg, Be: ≤0.5 μg/kg, Bi: ≤0.5 μg/kg, Ca: ≤20 μg/kg, Cd: ≤0.5 μg/kg, Ce: ≤0.5 μg/kg, Co: ≤0.5 μg/kg, Cr: ≤1 μg/kg, Cu: ≤1 μg/kg, Fe: ≤5 μg/kg, Ga: ≤0.5 μg/kg, Ge: ≤0.5 μg/kg, In: ≤0.5 μg/kg, Ir: ≤0.5 μg/kg, K: ≤10 μg/kg, Li: ≤0.5 μg/kg, Mg: ≤1 μg/kg, Mn: ≤0.5 μg/kg, Mo: ≤0.5 μg/kg, Na: ≤10 μg/kg, Ni: ≤1 μg/kg, Pb: ≤0.5 μg/kg, Pd: ≤1 μg/kg, Pt: ≤0.5 μg/kg, Rb: ≤0.5 μg/kg, Rh: ≤0.5 μg/kg, Ru: ≤0.5 μg/kg, Sb: ≤0.5 μg/kg, Sn: ≤0.5 μg/kg, Sr: ≤0.5 μg/kg, Ti: ≤1 μg/kg, Tl: ≤0.5 μg/kg, U: ≤0.5 μg/kg, V: ≤0.5 μg/kg, Zn: ≤50 μg/kg, Zr: ≤0.5 μg/kg

Application

ICP solvent is low odor and reduced toxicity equivalent to classical kerosene or xylene and ideal for dilution of oils and other organic fluids for determination of metal traces.

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
931040633556209
description

for inorganic trace analysis, ≥99.9995% (metals basis)

description

TraceCERT®, 10 g/L Cr in nitric acid (nominal concentration)

description

TraceCERT®, 1 g/L K in nitric acid (nominal concentration)

description

TraceCERT®, 10 g/L Fe in nitric acid (nominal concentration)

technique(s)

AAS: suitable, ICP: suitable

technique(s)

ICP: suitable

technique(s)

ICP: suitable

technique(s)

ICP: suitable

Quality Level

100

Quality Level

300

Quality Level

300

Quality Level

300

assay

≥99.9995% (metals basis)

assay

-

assay

-

assay

-

density

0.810-0.838 g/mL at 20 °C

density

-

density

-

density

-

bp

200-250 °C (lit.)

bp

-

bp

-

bp

-

cation traces

Pb: ≤0.5 μg/kg, Tl: ≤0.5 μg/kg, K: ≤10 μg/kg, Pd: ≤1 μg/kg, Au: ≤1 μg/kg, Sb: ≤0.5 μg/kg, Zn: ≤50 μg/kg, Ag: ≤1 μg/kg, Cu: ≤1 μg/kg, Cd: ≤0.5 μg/kg, Ca: ≤20 μg/kg, Ba: ≤0.5 μg/kg, Be: ≤0.5 μg/kg, As: ≤1 μg/kg, Mg: ≤1 μg/kg, Ru: ≤0.5 μg/kg, Al: ≤1 μg/kg, Ti: ≤1 μg/kg, Sn: ≤0.5 μg/kg, Pt: ≤0.5 μg/kg, Co: ≤0.5 μg/kg, Ge: ≤0.5 μg/kg, Cr: ≤1 μg/kg, Zr: ≤0.5 μg/kg, Ni: ≤1 μg/kg, Bi: ≤0.5 μg/kg, Mo: ≤0.5 μg/kg, Ga: ≤0.5 μg/kg, Sr: ≤0.5 μg/kg, Li: ≤0.5 μg/kg, Rh: ≤0.5 μg/kg, V: ≤0.5 μg/kg, In: ≤0.5 μg/kg, Ce: ≤0.5 μg/kg, Fe: ≤5 μg/kg, U: ≤0.5 μg/kg, Mn: ≤0.5 μg/kg

cation traces

-

cation traces

-

cation traces

-


Pictograms

Health hazard

Signal Word

Danger

Hazard Codes

Precautionary Statements

Hazard Classifications

Asp. Tox. 1

Storage Class

10 - Combustible liquids

Flash Point (°F)

158.0 °F

Flash Point (°C)

70 °C



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters