Skip to Content
MilliporeSigma

Skip To

65363

(R)-(−)-α-Methoxy-α-(trifluoromethyl)phenylacetyl chloride

derivatization grade (chiral), LiChropur™, ≥99.0%

Synonym(s):

(R)-(−)-MTPA-Cl, Mosher’s acid chloride

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
100 mg
Check Cart for Availability
$167.00
500 mg
Check Cart for Availability
$640.00

About This Item

Linear Formula:
C6H5C(OCH3)(CF3)COCl
CAS Number:
Molecular Weight:
252.62
UNSPSC Code:
23151817
NACRES:
NA.22
PubChem Substance ID:
MDL number:
Beilstein/REAXYS Number:
3591563
Assay:
≥99.0% (AT), ≥99.0%

$167.00


Check Cart for Availability

​
Request a Custom Order
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


grade

derivatization grade (chiral)

Quality Segment

product line

ChiraSelect™

assay

≥99.0% (AT), ≥99.0%

optical activity

[α]20/D −132±2°, c = 6 in chloroform

optical purity

enantiomeric ratio: ≥99.5:0.5 (GC)

quality

LiChropur™

technique(s)

HPLC: suitable

refractive index

n20/D 1.469, n20/D 1.47 (lit.)

bp

213-214 °C (lit.)

density

1.35 g/mL at 25 °C (lit.)

shipped in

wet ice

storage temp.

−20°C

SMILES string

CO[C@](C(Cl)=O)(c1ccccc1)C(F)(F)F

InChI

1S/C10H8ClF3O2/c1-16-9(8(11)15,10(12,13)14)7-5-3-2-4-6-7/h2-6H,1H3/t9-/m0/s1

InChI key

PAORVUMOXXAMPL-VIFPVBQESA-N

General description

(R)-(-)-a-Methoxy-a-(trifluoromethyl)phenylacetyl chloride (Mosher′s acid chloride) is generally used as a chiral derivatizing agent. It is easily available in enantiomerically pure form. It can form diastereomers with both alcohols and amines.

Application

Ready-to-use reagent for the determination of the enantiomeric purity of alcohols and amines after derivatization; doi:10.1038/nprot.2007.354
It was used for derivatizing D-arabinitol and L-arabinitol samples for high performance thin layer chromatography (HPTLC) analysis for studying resolution of the diastereoisomer.

Packaging

Bottomless glass bottle. Contents are inside inserted fused cone.

Other Notes

Discover LiChropur reagents ideal for HPLC or LC-MS analysis
Please note that R(-)-MTPA-Cl is derived from S(-)-MTPA

Legal Information

ChiraSelect is a trademark of Sigma-Aldrich Co. LLC
LiChropur is a trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
36967565365318035
description

derivatization grade (chiral), LiChropur™, ≥99.0%

description

99%

description

derivatization grade (chiral), LiChropur™, ≥99.0%

description

≥99%

assay

≥99.0% (AT)

assay

99%

assay

≥99.0% (AT)

assay

≥99%

Quality Level

100

Quality Level

200

Quality Level

100

Quality Level

200

refractive index

n20/D 1.47 (lit.), n20/D 1.469

refractive index

n20/D 1.469 (lit.)

refractive index

n20/D 1.469

refractive index

n20/D 1.474 (lit.)

bp

213-214 °C (lit.)

bp

213-214 °C (lit.)

bp

213-214 °C (lit.)

bp

95-97 °C/0.05 mmHg (lit.)

storage temp.

−20°C

storage temp.

−20°C

storage temp.

−20°C

storage temp.

2-8°C

density

1.35 g/mL at 25 °C (lit.)

density

1.35 g/mL at 25 °C (lit.)

density

1.35 g/mL at 25 °C (lit.)

density

1.303 g/mL at 25 °C (lit.)


Pictograms

Corrosion

Signal Word

Danger

Hazard Codes

Hazard Classifications

Skin Corr. 1B

Storage Class

8A - Combustible corrosive hazardous materials

WGK

WGK 3

Flash Point (°F)

192.2 °F - closed cup

Flash Point (°C)

89 °C - closed cup

PPE (personal protective equipment)

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters