Skip to Content
MilliporeSigma

Skip To

77619

Phenol – chloroform – isoamyl alcohol mixture

BioUltra, Molecular Biology, 125:24:1

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
100 mL

Available to ship TODAYfromMILWAUKEE

$122.00
500 mL

Available to ship TODAYfromMILWAUKEE

$425.00

About This Item

CAS Number:
NACRES:
ND.02
PubChem Substance ID:
UNSPSC Code:
12352200
MDL number:
Grade:
Molecular Biology

$122.00


Available to ship TODAYDetails


​
Request a Custom Order
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


grade

Molecular Biology

Quality Segment

product line

BioUltra

form

liquid

impurities

DNases, none detected, RNases, none detected, phosphatases, none detected, proteases, none detected

pH

4-5(H2O-phase, after extraction with H2O, 1:1)

density

1.12 g/mL at 20 °C

λ

neat

UV absorption

λ: 330 nm Amax: 0.2, λ: 405 nm Amax: 0.1, λ: 510 nm Amax: 0.1

storage temp.

2-8°C

SMILES string

ClC(Cl)Cl.CC(C)CCO.Oc1ccccc1

InChI

1S/C6H6O.C5H12O.CHCl3/c7-6-4-2-1-3-5-6;1-5(2)3-4-6;2-1(3)4/h1-5,7H;5-6H,3-4H2,1-2H3;1H

InChI key

ZYWFEOZQIUMEGL-UHFFFAOYSA-N

Application


  • Simultaneous quantification of multiple RNA cargos co-loaded into nanoparticle-based delivery systems: This research explores the application of the Phenol – chloroform – isoamyl alcohol mixture in extracting high-quality RNA for advanced therapeutic formulations, emphasizing its critical role in nanotechnology and pharmaceutical sciences (Lokras et al., 2022).

  • Analysis of Circulating microRNAs and Their Post-Transcriptional Modifications in Cancer Serum by On-Line Solid-Phase Extraction-Capillary Electrophoresis-Mass Spectrometry: Demonstrates the use of the Phenol – chloroform – isoamyl alcohol mixture for precise extraction of microRNAs from biological fluids, contributing to cancer diagnostics and molecular pathology (Pero-Gascon et al., 2018).

  • The application of alkaline lysis and pressure cycling technology in the differential extraction of DNA from sperm and epithelial cells recovered from cotton swabs: Highlights the integration of the Phenol – chloroform – isoamyl alcohol mixture with novel technologies for forensic applications, enhancing DNA extraction processes critical in legal and criminal investigations (Nori and McCord, 2015).

  • Frequency of Epstein-Barr virus DNA sequences in human gliomas: Utilizes the Phenol – chloroform – isoamyl alcohol mixture for DNA extraction in medical research, facilitating the study of viral presence in cancer tissues and its implications for oncology and virology (Fonseca et al., 2015).

  • The critical role of DNA extraction for detection of mycobacteria in tissues: This study underscores the effectiveness of the Phenol – chloroform – isoamyl alcohol mixture in the molecular detection of pathogens, serving as a fundamental technique in microbiological diagnostics and infectious disease research (Radomski et al., 2013).

Physical form

mixture of phenol; chloroform; isoamyl alcohol in the ratio of 125:24:1 (v/v/v); saturated with 2 M NaOAc pH 4

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
776187761725666
description

BioUltra, Molecular Biology, 125:24:1

description

BioUltra, Molecular Biology, 49.5:49.5:1

description

BioUltra, Molecular Biology, 25:24:1

description

BioUltra, Molecular Biology, 24:1, ≥99.5% (chloroform + isoamyl alcohol, GC)

Quality Level

100

Quality Level

100

Quality Level

200

Quality Level

100

grade

Molecular Biology

grade

Molecular Biology

grade

Molecular Biology

grade

Molecular Biology

form

liquid

form

liquid

form

liquid

form

liquid

UV absorption

λ: 330 nm Amax: 0.2, λ: 405 nm Amax: 0.1, λ: 510 nm Amax: 0.1

UV absorption

-

UV absorption

-

UV absorption

λ: 260 nm Amax: 0.15, λ: 280 nm Amax: 0.1

density

1.12 g/mL at 20 °C

density

1.29 g/mL at 20 °C

density

1.28 g/mL at 20 °C

density

-

impurities

RNases, none detected, DNases, none detected, proteases, none detected, phosphatases, none detected

impurities

proteases, none detected, DNases, none detected, RNases, none detected, phosphatases, none detected

impurities

phosphatases, none detected, RNases, none detected, DNases, none detected, proteases, none detected

impurities

insoluble matter, passes filter test, ≤0.001% free alkali (as NH3), RNases, none detected, phosphatases, none detected, DNases, none detected, proteases, none detected


Still not finding the right product?


Signal Word

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Aquatic Chronic 2 - Carc. 2 - Eye Dam. 1 - Muta. 2 - Repr. 2 - Skin Corr. 1B - STOT RE 1 Oral - STOT RE 2

Target Organs

Liver,Kidney, Nervous system,Kidney,Liver,Skin

Storage Class

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

WGK

WGK 3

PPE (personal protective equipment)

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

Active Filters

  1. Vancouver, BC
    • Review 1
    • Votes 3
    1 out of 5 stars.

    Did not work as a replacement for P1944 to isolate RNA

    We used to use P1944, but it was back ordered. So we decided to give this product a try.

    We performed RNA extractions from the same culture using either P1944 or 77619. P1944 gave intact ribosomal bands with high concentration, whereas 77619 gave low concentration of RNA with degraded RNA.

    We reached out, received no technical support, but was offered a refund.

    Helpful?

    1. Response from MilliporeSigma:

      Thank you for taking the time to leave a review! We are sorry to hear that your experience did not meet expectations and apologize that no technical support was provided at the time of refund. A member of our Technical Service team will be contacting you shortly in order to troubleshoot this issue and suggest a replacement product.