Skip to Content
MilliporeSigma

Skip To

293261

4-Methyl-2-pentanone

suitable for HPLC, ≥99.5%

Synonym(s):

Isobutyl methyl ketone, Isopropylacetone, MIBK, Methyl isobutyl ketone

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
100 mL
Check Cart for Availability
$86.30
1 L
Check Cart for Availability
$137.00
2 L
Check Cart for Availability
$199.00
4 x 4 L
Check Cart for Availability
$1,020.00

About This Item

Linear Formula:
(CH3)2CHCH2COCH3
CAS Number:
Molecular Weight:
100.16
UNSPSC Code:
12190000
NACRES:
NA.21
PubChem Substance ID:
EC Number:
203-550-1
Beilstein/REAXYS Number:
605399
MDL number:
Assay:
≥99.5%
Grade:
HPLC grade
Technique(s):
HPLC: suitable
Bp:
117-118 °C
Vapor pressure:
15.7 mmHg

$86.30


Check Cart for Availability

​
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


grade

HPLC grade

Quality Segment

vapor density

3.5 (vs air)

vapor pressure

15.7 mmHg

assay

≥99.5%

form

liquid

autoignition temp.

840 °F

expl. lim.

1.2-8 %, 93 °F

technique(s)

HPLC: suitable

impurities

<0.050% water

evapn. residue

<0.001%

refractive index

n20/D 1.395 (lit.)

bp

117-118 °C

mp

−80 °C (lit.)

density

0.801 g/mL at 25 °C (lit.)

λ

H2O reference

UV absorption

λ: 335 nm Amax: 1.00, λ: 340 nm Amax: 0.50, λ: 360 nm Amax: 0.15, λ: 380 nm Amax: 0.02, λ: 400 nm Amax: 0.01

application(s)

food and beverages

SMILES string

CC(C)CC(C)=O

InChI

1S/C6H12O/c1-5(2)4-6(3)7/h5H,4H2,1-3H3

InChI key

NTIZESTWPVYFNL-UHFFFAOYSA-N

General description

This solvent is glass distilled, submicron filtered and subjected to rigorous specification testing to provide lot-to-lot consistency.

Application

Designed for use with HPLC instrumentation and organic synthesis applications.
Featured as a solvent in the extraction of cellulose-derived levulinic acid from municipal wastewater treatment plant (WWTP) sludge prior to HPLC analysis.

Packaging

M-Bottle for Solvents
As a global leader in lab reagents, we are constantly looking for new ways to optimize the safety of our products. The newly developed 4L solvent bottle design features advanced sealing technology that eliminates leaks to make the handling of solvents safer and more convenient than ever before.
See all the new features here!

Other Notes

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
360511MX1300MX1301
description

suitable for HPLC, ≥99.5%

description

ACS reagent, ≥98.5%

description

Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs GR ACS

description

OmniSolv®

assay

≥99.5%

assay

≥98.5%

assay

≥98.5% (GC)

assay

≥99% (GC)

application(s)

food and beverages

application(s)

-

application(s)

-

application(s)

-

technique(s)

HPLC: suitable

technique(s)

-

technique(s)

-

technique(s)

HPLC: suitable, LC/MS: suitable, gas chromatography (GC): suitable

Quality Level

100

Quality Level

200

Quality Level

200

Quality Level

100

grade

HPLC grade

grade

ACS reagent

grade

-

grade

-

form

liquid

form

liquid

form

liquid

form

liquid


Still not finding the right product?

Explore all of our products under 4-Methyl-2-pentanone


Signal Word

Danger

Hazard Classifications

Acute Tox. 4 Inhalation - Carc. 2 Inhalation - Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 3

Target Organs

Central nervous system

supp_hazards

Storage Class

3 - Flammable liquids

WGK

WGK 1

Flash Point (°F)

57.2 °F - closed cup

Flash Point (°C)

14 °C - closed cup



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters