Passa al contenuto
Merck

T-037

Testosterone solution

1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®

Testosterone solution
Autenticati per visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

Prezzi e disponibilità al momento non sono disponibili

Informazioni su questo articolo

Formula empirica (notazione di Hill):
C19H28O2
Numero CAS:
Peso molecolare:
288.42
Numero MDL:
Codice UNSPSC:
41116107
ID PubChem:
NACRES:
NA.24

Vai a

Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti

Grado

certified reference material

Livello qualitativo

Stato

liquid

Caratteristiche

Snap-N-Spike®/Snap-N-Shoot®

Confezionamento

ampule of 1 mL

Produttore/marchio commerciale

Cerilliant®

Concentrazione

1.0 mg/mL in acetonitrile

tecniche

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

applicazioni

clinical testing

Formato

single component solution

Temperatura di conservazione

−20°C

Stringa SMILE

CC12CCC3C(CCC4=CC(=O)CCC34C)C1CCC2O

InChI

1S/C19H28O2/c1-18-9-7-13(20)11-12(18)3-4-14-15-5-6-17(21)19(15,2)10-8-16(14)18/h11,14-17,21H,3-10H2,1-2H3/t14-,15-,16-,17-,18-,19-/m0/s1
MUMGGOZAMZWBJJ-DYKIIFRCSA-N

Informazioni sul gene

human ... AR(367)

Confronta articoli simili

Visualizza il confronto per intero

Mostra le differenze

1 of 4

Questo articolo
T5411PHR2027T0100000
Testosterone solution 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®

Supelco

T-037

Testosterone solution

Testosterone solution 1.0 mg/mL in 1,2-dimethoxyethane, drug standard

Supelco

T5411

Testosterone solution

Testosterone Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR2027

Testosterone

Testosterone European Pharmacopoeia (EP) Reference Standard

T0100000

Testosterone

application(s)

clinical testing

application(s)

clinical testing

application(s)

pharmaceutical

application(s)

pharmaceutical (small molecule)

technique(s)

gas chromatography (GC): suitable, liquid chromatography (LC): suitable

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

technique(s)

-

technique(s)

-

form

liquid

form

-

form

-

form

-

format

single component solution

format

single component solution

format

neat

format

neat

Quality Level

300

Quality Level

200

Quality Level

300

Quality Level

-

grade

certified reference material

grade

drug standard

grade

certified reference material, pharmaceutical secondary standard

grade

pharmaceutical primary standard

Descrizione generale

A certified solution standard applicable to use in sports testing, urine drug testing, and diagnostic testing by LC-MS/MS or GC/MS. Testosterone, a hormone from the androgen group, is an important sex hormone and anabolic steroid often abused in sports.

Note legali

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

Prodotti correlati

N° Catalogo
Descrizione
Determinazione del prezzo

Pittogrammi

FlameExclamation mark

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

Codice della classe di stoccaggio

3 - Flammable liquids

Classe di pericolosità dell'acqua (WGK)

WGK 2

Punto d’infiammabilità (°F)

35.6 °F - closed cup

Punto d’infiammabilità (°C)

2 °C - closed cup


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Frances S Chen et al.
Social cognitive and affective neuroscience, 10(6), 797-800 (2014-09-07)
Physical size and strength are associated with dominance and threat. The current study tested (i) whether men's evaluations of male strangers would be negatively influenced by cues indicating physical formidability, and (ii) whether these evaluations would be influenced by oxytocin
Andrea C Lo et al.
International journal of radiation oncology, biology, physics, 88(1), 87-93 (2013-12-18)
To determine (1) the prognostic utility of prostate-specific antigen (PSA) concentration at 45 to 60 months (48mPSA) after low-dose-rate prostate brachytherapy (LDR-PB); (2) the predictors of 48mPSA; and (3) the prognostic utility of directional trends between PSA levels at 24
James R Bell et al.
American journal of physiology. Heart and circulatory physiology, 306(9), H1265-H1274 (2014-03-13)
Estrogen in females is conventionally considered a cardioprotective influence, but a role for estrogen in male cardioprotection has yet to be defined. Estrogen biosynthesis from testosterone is regulated by aromatase. Aromatase has recently been shown to be expressed in the
David J Handelsman
The Journal of clinical endocrinology and metabolism, 91(5), 1646-1653 (2006-02-16)
The objective of the study was to review the rationale underlying the banning of human chorionic gonadotropin (hCG) and estrogen blockers (antiestrogens, specific estrogen receptor modulators, aromatase inhibitors) in sports for male and female athletes in the light of gender
Y Zimmerman et al.
Human reproduction update, 20(1), 76-105 (2013-10-02)
BACKGROUND; Combined oral contraceptives (COCs) reduce levels of androgen, especially testosterone (T), by inhibiting ovarian and adrenal androgen synthesis and by increasing levels of sex hormone-binding globulin (SHBG). Although this suppressive effect has been investigated by numerous studies over many

Articoli

Optimize serum samples for LC-MS/MS-based free testosterone determination using Supel™ BioSPME 96-pin device and validated equilibrium dialysis methods.

Accurate steroid analysis in blood serum using Supel™ Swift HLB DPX Tips; UTAK and NIST standards.

Protocolli

The conversion of clinical methods to LC/MS/MS offers advantages; however, is accompanied by a few limitations, notably interference effects from the endogenous sample matrix.

Domande

1–2 di 2 domande  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 risposta
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Utile?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 risposta
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Utile?

Recensioni

Filtri attivi

  1. 1 recensione solo con voto

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica