Passa al contenuto
Merck

CRK1M0203

Filtro per cartuccia Polygard® CR

pore size 1.0 μm, cartridge nominal length 2 in. (5 cm), Code M (2-118; O-rings)

Sinonimo/i:

Polygard-CR Cartridge Filter 2 in. 0.1 μm Code M Silicone

Autenticati per visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

3 EA

417,00 €

417,00 €


Spedizione prevista per OGGIDettagli



Informazioni su questo articolo

Codice UNSPSC:
23151806
eCl@ss:
32031690

Vai a

Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti

Materiali

polypropylene
silicone seal

Livello qualitativo

Caratteristiche

hydrophilic

Produttore/marchio commerciale

Polygard

Parametri

4.8 bar max. differential pressure (70 psid) at 25 °C
4.8 bar max. inlet pressure (70 psi) at 25 °C

Lunghezza nominale della cartuccia

2 in. (5 cm)

Diametro

7.0 cm (2.75 in.)

Impurezze

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

Estraibili (gravimetria)

≤50 mg

Dimensione pori

0.1 μm nominal pore size
1.0 μm pore size

input

sample type liquid

Codice cartuccia

Code M (2-118; O-rings)

Confronta articoli simili

Visualizza il confronto per intero

Mostra le differenze

1 of 4

Questo articolo
CR01M0203CRA5M0203CR99M0203
material

polypropylene , silicone seal

material

polypropylene , silicone seal

material

polypropylene , silicone seal

material

polypropylene , silicone seal

impurities

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

impurities

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

impurities

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

impurities

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

feature

hydrophilic

parameter

4.8 bar max. differential pressure (70 psid) at 25 °C

parameter

4.8 bar max. differential pressure (70 psid) at 25 °C, 4.8 bar max. inlet pressure (70 psi) at 25 °C

parameter

4.8 bar max. differential pressure (70 psid) at 25 °C, 4.8 bar max. inlet pressure (70 psi) at 25 °C

parameter

4.8 bar max. differential pressure (70 psid) at 25 °C, 4.8 bar max. inlet pressure (70 psi) at 25 °C

manufacturer/tradename

Polygard

manufacturer/tradename

Polygard

manufacturer/tradename

Polygard

manufacturer/tradename

Polygard

cartridge nominal length

2 in. (5 cm)

cartridge nominal length

2 in. (5 cm)

cartridge nominal length

2 in. (5 cm)

cartridge nominal length

2 in. (5 cm)

Descrizione generale

The Polygard® CR Cartridge Filter products are nominally rated filters designed for particle removal applications in liquids and gases. The graded-density depth structure of Polygard-CR filter media provides maximum filtration capacity, a 1.0 μm pore size and the all-polypropylene construction offers low extractables levels and broad chemical compatibility.

Polygard-CR cartridge filters provide high throughput with 4.8 bar max. differential pressure (70 psid) at 25 °C.

Typical Applications
Polygard-CR high-efficiency cartridge filters, composed of graded density polypropylene media are widely used in the beverage industry for liquid and gas filtration applications to protect tighter filters.

Regulatory Compliance
Polygard® CR Cartridge Filters are designed, developed, and manufactured in accordance with a Quality Management System approved by an accredited registering body to an ISO 9000 Quality Systems Standard and are shipped with a Certificate of Quality. Each cartridge filter is supported by a Validation Guide for compliance with regulatory requirements.

For traceability and easy identification, each filter is marked with identifying characteristics.

Multiple Formats Available
Polygard-CR product line offers a full range of filtration areas is available to suit varying application requirements. A variety of connection options are offered for easy adaptation to existing housings.

These devices have been developed to minimize hold-up volume when evaluating multiple media configurations.

Nota sulla preparazione

Sanitization Protocol
30 min with hot water @ 80 °C
Sterilization Method
10 autoclave cycles or SIP @ 126 °C for 30 min

Risultati analitici

Gravimetric Extractables: after 24-h soak in water

Note legali

POLYGARD is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Domande

Recensioni

Nessuna valutazione

Filtri attivi

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica