Passa al contenuto
Merck

HSTCMAG-28SK

MILLIPLEX® Human High Sensitivity T Cell Panel - Immunology Multiplex Assay

Simultaneous analyze low levels of cytokine and chemokine biomarker with the High Sensitivity Bead-Based Multiplex Assays using the Luminex technology, in human serum, plasma and cell culture samples.

Sinonimo/i:

Human high-sensitivity cytokine multiplex kit, Luminex® human high-sensitivity cytokine immunoassay, Millipore human high-sensitivity cytokine panel

Autenticati per visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Informazioni su questo articolo

Codice UNSPSC:
12161503
eCl@ss:
32161000
NACRES:
NA.47

To order a Milliplex® kit, please search for your analyte of interest.

Vai a

Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti

Livello qualitativo

Reattività contro le specie

human

Produttore/marchio commerciale

Milliplex®

assay range

accuracy: 98-107%
sensitivity: 0.11-8.17 pg/mL
(Overnight Incubation minDC)

standard curve range: 0.18-750 pg/mL
(IL-6)

standard curve range: 0.24-1,000 pg/mL
(IL-13)

standard curve range: 0.24-1,000 pg/mL
(IL-21)

standard curve range: 0.31-1,250 pg/mL
(IL-8)

standard curve range: 0.31-1,250 pg/mL
(MIP-1α)

standard curve range: 0.37-1,500 pg/mL
(IL-7)

standard curve range: 0.45-1,750 pg/mL
(TNFα)

standard curve range: 0.49-2,000 pg/mL
(IL-1β)

standard curve range: 0.49-2,000 pg/mL
(IL-12 (p70))

standard curve range: 0.49-2,000 pg/mL
(IL-2)

standard curve range: 0.49-2,000 pg/mL
(IL-5)

standard curve range: 0.61-2,500 pg/mL
(IFNγ)

standard curve range: 0.61-2,500 pg/mL
(MIP-3α)

standard curve range: 0.73-3,000 pg/mL
(IL-17A)

standard curve range: 0.92-3,750 pg/mL
(MIP-1β)

standard curve range: 1.22-5,000 pg/mL
(GM-CSF)

standard curve range: 1.46-6,000 pg/mL
(IL-10)

standard curve range: 1.46-6,000 pg/mL
(ITAC)

standard curve range: 1.83-7,500 pg/mL
(IL-4)

standard curve range: 18.3-75,000 pg/mL
(Fractalkine)

standard curve range: 7.93-32,500 pg/mL
(IL-23)

inter-assay cv: <15%
intra-assay cv: <10%

tecniche

multiplexing: suitable

Metodo di rivelazione

fluorometric (Luminex xMAP)

Condizioni di spedizione

wet ice

Confronta articoli simili

Visualizza il confronto per intero

Mostra le differenze

1 of 4

Questo articolo
MHSTCMAG-70KMHSTCMAG-70KPMXHCYTA-60K-PX48
species reactivity

human

species reactivity

mouse

species reactivity

mouse

species reactivity

human

assay range

accuracy: 98-107%, standard curve range: 0.18-750 pg/mL
(IL-6), standard curve range: 0.24-1,000 pg/mL
(IL-21), standard curve range: 0.31-1,250 pg/mL
(MIP-1α), standard curve range: 0.45-1,750 pg/mL
(TNFα), standard curve range: 0.49-2,000 pg/mL
(IL-12 (p70)), standard curve range: 0.49-2,000 pg/mL
(IL-5), standard curve range: 0.61-2,500 pg/mL
(MIP-3α), standard curve range: 0.92-3,750 pg/mL
(MIP-1β), standard curve range: 1.46-6,000 pg/mL
(IL-10), standard curve range: 1.83-7,500 pg/mL
(IL-4), standard curve range: 7.93-32,500 pg/mL
(IL-23), inter-assay cv: <15%
intra-assay cv: <10%, standard curve range: 0.24-1,000 pg/mL
(IL-13), standard curve range: 0.37-1,500 pg/mL
(IL-7), standard curve range: 0.49-2,000 pg/mL
(IL-2), standard curve range: 0.73-3,000 pg/mL
(IL-17A), standard curve range: 1.46-6,000 pg/mL
(ITAC), sensitivity: 0.11-8.17 pg/mL
(Overnight Incubation minDC), standard curve range: 0.49-2,000 pg/mL
(IL-1β), standard curve range: 1.22-5,000 pg/mL
(GM-CSF), standard curve range: 0.31-1,250 pg/mL
(IL-8), standard curve range: 18.3-75,000 pg/mL
(Fractalkine), standard curve range: 0.61-2,500 pg/mL
(IFNγ)

assay range

accuracy: 82-102%, sensitivity: 0.26-11.14 pg/mL, standard curve range: 0.10-400 pg/mL
(IL-4), standard curve range: 0.49-2,000 pg/mL
(IFNγ), standard curve range: 0.49-2,000 pg/mL
(IL-17A), standard curve range: 0.49-2,000 pg/mL
(IL-7), standard curve range: 0.49-2,000 pg/mL
(TNFα), standard curve range: 0.73-3,000 pg/mL
(KC/GROα/CXCL1), standard curve range: 0.98-4,000 pg/mL
(IL-2), standard curve range: 0.98-4,000 pg/mL
(IL-5), standard curve range: 0.98-4,000 pg/mL
(IL-6), standard curve range: 1.34-5,500 pg/mL
(IL-10), standard curve range: 2.93-12,000 pg/mL
(IL-12 (p70)), standard curve range: 3.17-13,000 pg/mL
(LIX), standard curve range: 3.42-14.000 pg/mL
(IL-13), standard curve range: 3.91-16,000 pg/mL
(IL-1α), standard curve range: 3.91-16,000 pg/mL
(IL-1β), standard curve range: 3.91-16,000 pg/mL
(MCP-1/CCL2), standard curve range: 6.1-25,000 pg/mL
(GM-CSF), standard curve range: 7.32-30,000 pg/mL
(MIP-2/CXCL2), inter-assay cv: <15%
intra-assay cv: <10%

assay range

accuracy: 82-102%, sensitivity: 0.26-11.14 pg/mL, standard curve range: 0.10-400 pg/mL
(IL-4), standard curve range: 0.49-2,000 pg/mL
(IFNγ), standard curve range: 0.49-2,000 pg/mL
(IL-17A), standard curve range: 0.49-2,000 pg/mL
(IL-7), standard curve range: 0.49-2,000 pg/mL
(TNFα), standard curve range: 0.73-3,000 pg/mL
(KC/GROα/CXCL1), standard curve range: 0.98-4,000 pg/mL
(IL-2), standard curve range: 0.98-4,000 pg/mL
(IL-5), standard curve range: 0.98-4,000 pg/mL
(IL-6), standard curve range: 1.34-5,500 pg/mL
(IL-10), standard curve range: 2.93-12,000 pg/mL
(IL-12 (p70)), standard curve range: 3.17-13,000 pg/mL
(MCP-1/CCL2), standard curve range: 3.42-14,000 pg/mL
(IL-13), standard curve range: 3.91-16,000 pg/mL
(IL-1α), standard curve range: 3.91-16,000 pg/mL
(IL-1β), standard curve range: 6.1-25,000 pg/mL
(GM-CSF), standard curve range: 7.32-30,000 pg/mL
(MIP-2/CXCL2), standard curve range: 9.77-40,000 pg/mL
(LIX), inter-assay cv: <15%
intra-assay cv: <10%

assay range

-

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

detection method

fluorometric (Luminex xMAP)

detection method

fluorometric (Luminex xMAP)

detection method

fluorometric (Luminex xMAP)

detection method

fluorometric (Luminex® xMAP®)

shipped in

wet ice

shipped in

ambient

shipped in

ambient

shipped in

-

Descrizione generale

Cytokines are immunomodulatory polypeptides that play key roles in both adaptive and innate immune responses. A generic term, “cytokines” includes myokines (produced by muscle cells), lymphokines (produced by activated Th cells), interleukins (acting as mediators between T cells) and chemokines (responsible for T-cell migration). One of the regulatory mechanisms of the immune system, cytokines act at the recognition, activation, or effector phases of an immune response, modulating the development and functional activities of the subtypes of T cells, B cells and myeloid cells. Consequently, research involving cytokines plays a significant role in achieving a deeper understanding of the immune system and its multi-faceted response to most antigens, especially those responses that make up the inflammatory process. Low levels of inflammation are involved in many clinical and sub-clinical disease states, such as autoimmune disease, cardiovascular disease, diabetes, neurological disorders, and cancer. Measuring picogram levels of cytokines, therefore, is critical for understanding the pathogenesis of these diseases.

The MILLIPLEX® Human High Sensitivity T Cell Magnetic Bead Panel is to be used for the simultaneous quantification of any or all of the following analytes in human plasma, serum, and cell/tissue culture supernatant samples: Fractalkine, GM-CSF, IFNγ, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-10, IL-12 (p70), IL-13, IL-17A, IL-21, IL-23, ITAC, MIP-1α, MIP-1β, MIP-3α
and TNFα.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Cytokines/Chemokines

Applicazioni

  • Analytes: Fractalkine, GM-CSF, IFNγ, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-10, IL-12 (p70), IL-13, IL-17A, IL-21, IL-23, I-TAC, MIP-1α, MIP-1β, MIP-3α, TNF-α
  • Because there are unique features concerning sample prep and assay set-up, please read the entire protocol before running the assay.
  • Recommended Sample type: Serum, plasma or tissue/cell lysate and culture supernatant
  • Assay Run Time: Overnight
  • Research Category: Inflammation & Immunology
  • Research Subcategory: Immune Response, Metabolic Disorders, Chronic Inflammatory Disease, Cardiovascular Disease, Neuroscience

Azioni biochim/fisiol

Cross Reactivty
There is no detectable cross-reactivity within the panel.
Cross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.

Caratteristiche e vantaggi

Design your multiplex kit by choosing available analytes within this panel.

Nota sulla preparazione

Recommended storage for kit components is 2 - 8°C.

Altre note

Please contact Technical Service for linearity of dilution.
Replaces: HSTCMAG-28SK; HSCYTMAG-60SK
Sensitivity: Please see kit protocol for individual assay sensitivities.

Note legali

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Esclusione di responsabilità

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Avvertenze

Danger

Classi di pericolo

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

Organi bersaglio

Respiratory Tract

Codice della classe di stoccaggio

10 - Combustible liquids


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Matteo Ravaioli et al.
Scientific reports, 10(1), 6063-6063 (2020-04-10)
With the aim to explore innovative tools for organ preservation, especially in marginal organs, we hereby describe a clinical trial of ex-vivo hypothermic oxygenated perfusion (HOPE) in the field of liver (LT) and kidney transplantation (KT) from Extended Criteria Donors
Anne H Krog et al.
Vascular health and risk management, 12, 371-378 (2016-10-08)
Minimally invasive surgical techniques have been shown to reduce the inflammatory response related to a surgical procedure. The main objective of our study was to measure the inflammatory response in patients undergoing a totally laparoscopic versus open aortobifemoral bypass surgery.
Luiz C F Romanelli et al.
PLoS neglected tropical diseases, 12(8), e0006720-e0006720 (2018-08-28)
HTLV-1 infection is endemic in Brazil. About 1 to 2% of the Brazilian population is estimated to be infected, but most infected HTLV-1 individuals do not know about their own infection, which favors the continuity of sexual and vertical virus
Abstracts of the XXXVIII Congress of the Spanish Society of Physiological Sciences (SECF), 13-16 September 2016, Zaragoza, Spain.
Journal of physiology and biochemistry, 72 Suppl 1, 1-111 (2016-08-16)
Malcolm Sanderson et al.
Sports (Basel, Switzerland), 8(12) (2020-12-05)
Swimming is a popular youth sport that is considered beneficial for cardiovascular fitness. However, the potential inflammatory outcomes of high intensity swimming in younger swimmers are unclear, as is the response of irisin, a myokine released during exercise with anti-inflammatory

Contenuto correlato

Immunology multiplex assays, like MILLIPLEX® assays, allow researchers to investigate more immune biomarkers simultaneously, saving time and resources.

Vedi tutto

Domande

  1. Could you provide me with more information about the T cell cytokine assay, including CV values and detection limits? The current information I have is that serum concentrations of 13 human cytokines (IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-10, IL-12p70, IL-13, GM-CSF, IFN-γ, and TNF-α) were quantified (pg/ml) in the serum of 52 matched cord blood and maternal venous blood samples using the human 13-plex magnetic bead assay (HCYTOMAG-60K). The assay protocol followed the manufacturer's guidelines, and standards and controls were included in each run. I also cc-ed Jennifer as she was involved in my work and may have previous information about technical reports.

    1 risposta
    1. The validation data and assay characteristics are provided in the back of each assay protocol.

      Utile?

Recensioni

Nessuna valutazione

Filtri attivi

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica