Extending the primary incubation step beyond the specified time in the kit protocol is not something that has been tested. A longer incubation time could potentially lead to decreased performance, including poor recovery or increased variability in assay characteristics. It may also result in higher nonspecific binding, leading to elevated signals in background wells and a loss of sensitivity.
Informazioni su questo articolo
Vai a
Nome del prodotto
MILLIPLEX® Human Th17 Panel, Configurable Human Th17 25-Plex Panel
species reactivity
human
Quality Level
packaging
pkg of 1 ea
manufacturer/tradename
Milliplex®
assay range
accuracy: 79-107%
standard curve range: 1-5000 pg/mL
(IL-10)
standard curve range: 10-40,000 pg/mL
(IFNγ)
standard curve range: 12-50,000 pg/mL
(IL-17A & IL-2)
standard curve range: 24-100,000 pg/mL
(IL-17 & IL-4)
standard curve range: 3-10,000 pg/mL
(IL-6 & TNFα)
standard curve range: 336-1,500,000 pg/mL
(IL-23)
standard curve range: 37-150,000 pg/mL
(IL-22 & TNFβ)
standard curve range: 488-2,000,000 pg/mL
(IL-17E/IL-25)
standard curve range: 49-200,000 pg/mL
(IL-28a & IL-31)
standard curve range: 5-20,000 pg/mL
(MIP-3α, IL-1β, IL-12 (p70), IL-15, IL-21 & IL-33)
standard curve range: 6-25,000 pg/mL
(IL-5)
standard curve range: 61-250,000 pg/mL
(GM-CSF & IL-27)
standard curve range: 7-30,000 pg/mL
(IL-13)
standard curve range: 9-35,000 pg/mL
(IL-9)
technique(s)
multiplexing: suitable
input
cell culture supernatant
serum
detection method
fluorometric (Luminex® xMAP® technology)
shipped in
wet ice
storage temp.
2-8°C
1 of 4
Questo articolo | MT17MAG47K-PX25 | HCD8MAG-15K | HT17MAG14PMX25BK |
|---|---|---|---|
| species reactivity human | species reactivity mouse | species reactivity human | species reactivity human |
| manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® |
| assay range accuracy: 79-107%, standard curve range: 10-40,000 pg/mL | assay range accuracy: 85-110%, linearity: 111.0% | assay range - | assay range - |
| Quality Level 200 | Quality Level 200 | Quality Level 200 | Quality Level 200 |
| shipped in wet ice | shipped in wet ice | shipped in wet ice | shipped in wet ice |
| detection method fluorometric (Luminex xMAP) | detection method fluorometric (Luminex xMAP) | detection method fluorometric (Luminex xMAP) | detection method fluorometric (Luminex xMAP) |
Legal Information
Application
Disclaimer
Features and Benefits
General description
signalword
Danger
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
target_organs
Respiratory Tract
Classe di stoccaggio
10 - Combustible liquids
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Contenuto correlato
Immunology multiplex assays, like MILLIPLEX® assays, allow researchers to investigate more immune biomarkers simultaneously, saving time and resources.
Discover the benefits of MILLIPLEX® multiplex assays, based on Luminex® xMAP® multiplex assay technology, that provide consistent, high-quality results and see how these multiplex biomarker Luminex® assays are being used to advance research.
See how multiplexing the inflammation signaling pathway with MILLIPLEX® inflammation assays or cell signaling assays can help researchers bridge the gap between immunology and cell signaling, including investigating T cell signaling, Th Cell differentiation, inflammatory response signaling, and sepsis signaling.
-
Could you please provide information on the potential effects of leaving samples on the shaker overnight for longer than 18 hours, for example, 24-30 hours instead of the recommended 16-18 hours?
1 risposta-
Utile?
-
Filtri attivi
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica