Passa al contenuto
Merck

P5379

Fosfato di potassio

ReagentPlus®

Sinonimo/i:

Fosfato di potassio prim., Potassio diidrogeno fosfato

Autenticati per visualizzare i prezzi organizzativi e contrattuali.

Scegli un formato

Prezzi e disponibilità al momento non sono disponibili

Informazioni su questo articolo

Formula condensata:
KH2PO4
Numero CAS:
Peso molecolare:
136.09
NACRES:
NA.25
PubChem Substance ID:
UNSPSC Code:
12161700
EC Number:
231-913-4
MDL number:

Vai a

Servizio Tecnico
Hai bisogno di aiuto? Il nostro team di scienziati qualificati è a tua disposizione.
Permettici di aiutarti

Nome del prodotto

Fosfato di potassio, ReagentPlus®

InChI key

GNSKLFRGEWLPPA-UHFFFAOYSA-M

InChI

1S/K.H3O4P/c;1-5(2,3)4/h;(H3,1,2,3,4)/q+1;/p-1

SMILES string

[K+].OP(O)([O-])=O

product line

ReagentPlus®

assay

≥99.0%

form

powder or crystals

pKa (25 °C)

(1) 2.15, (2) 6.82, (3) 12.38 (phosphoric acid)

mp

252.6 °C (lit.)

solubility

water: 100 mg/mL, clear, colorless

density

2.338 g/mL at 25 °C (lit.)

Quality Level

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Confronta articoli simili

Visualizza il confronto per intero

Mostra le differenze

1 of 4

Questo articolo
60220-MRDD0371.04877
Fosfato di potassio for analysis (® ACS,ISO,Reag. Ph Eur

Supelco

1.04877

Fosfato di potassio

assay

≥99.0%

assay

99.5-100.5%

assay

≥99.0%

assay

≥99.0% dry basis (alkalimetric), 98.0-100.5% (alkalimetric)

Quality Level

200

Quality Level

-

Quality Level

100

Quality Level

300

product line

ReagentPlus®

product line

-

product line

Redi-Dri

product line

EMSURE®

form

powder or crystals

form

crystalline

form

-

form

solid

solubility

water: 100 mg/mL, clear, colorless

solubility

-

solubility

-

solubility

-

density

2.338 g/mL at 25 °C (lit.)

density

2.338 g/mL at 25 °C (lit.)

density

2.338 g/mL at 25 °C (lit.)

density

2.338 g/mL at 25 °C (lit.)

Application

Potassium phosphate monobasic has been used:
  • in calibration curve generation in electrical conductivity measurement of plasma-activated tap water (PATW).[1]
  • as a component of dissection solution.[2]
  • as a constituent of phosphate buffered saline.[3]

Legal Information

ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany

Classe di stoccaggio

13 - Non Combustible Solids

wgk

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

A Rapid Extraction Method for mammalian cell cultures, suitable for quantitative immunoblotting analysis of proteins, including phosphorylated GCN2 and eIF2alpha
Silva RC, et al.
MethodsX, 5, 75-82 (2018)
Plasma-activation of tap water using DBD for agronomy applications: Identification and quantification of long lifetime chemical species and production/consumption mechanisms
Judee F, et al.
Water Research, 133, 47-59 (2018)
Astrocyte-enriched feeder layers from cryopreserved cells support differentiation of spontaneously active networks of human iPSC-derived neurons
Schutte RJ, et al.
Journal of Neuroscience Methods, 294, 91-101 (2018)
Przemyslaw Nogly et al.
IUCrJ, 2(Pt 2), 168-176 (2015-04-14)
Lipidic cubic phases (LCPs) have emerged as successful matrixes for the crystallization of membrane proteins. Moreover, the viscous LCP also provides a highly effective delivery medium for serial femtosecond crystallography (SFX) at X-ray free-electron lasers (XFELs). Here, the adaptation of
Casper Skovgaard et al.
Journal of applied physiology (Bethesda, Md. : 1985), 117(10), 1097-1109 (2014-09-06)
The purpose of this study was to examine whether speed endurance training (SET, repeated 30-s sprints) and heavy resistance training (HRT, 80-90% of 1 repetition maximum) performed in succession are compatible and lead to performance improvements in moderately trained endurance

Articoli

Cathepsin B is a lysosomal cysteine proteinase with broad specificity. This protocol uses Nα–CBZ–Arg–Arg–7–amido–4–methylcoumarin as the substrate for fluorometric detection of Cathepsin B activity.

Protocolli

Spectrophotometric assay evaluates malic dehydrogenase activity using bovine heart enzyme with critical histidine residue at active site.

To measure alcohol oxidase activity, this assay uses 2,2′-azino-bis-(3-ethylbenzothiazoline-6-sulfonic acid) and a continuous spectrophotometric rate determination at 405 nm.

Enzymatic activity assay for cholesterol oxidase, excluding specific product numbers, providing guidelines for accurate cholesterol oxidase assays.

Protocol for Enzymatic Assay of Plasmin with D-Val-Leu-Lys-p-Nitroanilide Dihydrochloride

Vedi tutto

Contenuto correlato

Discover high-purity biological buffers for production scale. Ensure stability, pH control, and consistent supply with our expert manufacturing solutions.

Scoprite i nostri tamponi biologici di elevata purezza in volumi di processo. Con le nostre soluzioni produttive qualificate, vi assicurerete stabilità, controllo del pH e forniture costanti.

Domande

1–2 di 2 domande  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 risposta
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Utile?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 risposta
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Utile?

Recensioni

Nessuna valutazione

Filtri attivi

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica