Thank you for your rating. We encourage customers who experience problems with our products to call or email us for additional technical support. Please visit https://www.sigmaaldrich.com/US/en/support/customer-support to submit a Product Technical Inquiry.
ログインで組織・契約価格をご覧ください。
サイズを選択してください
表示を変更する
| サイズ/SKU | 在庫状況 | 単価 |
|---|
この商品について
Assay:
≥95% (GC)
Bp:
28 °C/1013 hPa
Vapor pressure:
800 hPa ( 20 °C)
現在、価格および在庫状況を閲覧できません。
vapor pressure
800 hPa ( 20 °C)
Quality Segment
assay
≥95% (GC)
form
liquid
color
APHA: ≤30
bp
28 °C/1013 hPa
mp
-160 °C
transition temp
flash point -57 °C
solubility
0.048 g/L
density
0.62 g/cm3 at 20 °C
shipped in
ambient
storage temp.
room temp
SMILES string
C(CC)(C)C
InChI
1S/C5H12/c1-4-5(2)3/h5H,4H2,1-3H3
InChI key
QWTDNUCVQCZILF-UHFFFAOYSA-N
General description
EMPARTA solvents are designed for routine chemical synthesis, drying, purification, and critical labware cleaning in quality control environments. Engineered for precision, they deliver consistently reproducible results essential for rigorous validation and documentation.
Exceptional Quality Standards: These solvents meet or exceed ACS specifications, providing assurance of high quality that is crucial for accurate testing and analysis in quality control.
Consistent Reproducibility: Designed for precision, the solvents ensure that results can be reliably reproduced, which is vital for maintaining compliance and integrity in quality control processes.
Versatile Applications: Suitable for a variety of QC tasks, including analytical testing, method validation, and testing USP/NF monographs, these solvents support a comprehensive approach to quality assurance in laboratory settings.
Exceptional Quality Standards: These solvents meet or exceed ACS specifications, providing assurance of high quality that is crucial for accurate testing and analysis in quality control.
Consistent Reproducibility: Designed for precision, the solvents ensure that results can be reliably reproduced, which is vital for maintaining compliance and integrity in quality control processes.
Versatile Applications: Suitable for a variety of QC tasks, including analytical testing, method validation, and testing USP/NF monographs, these solvents support a comprehensive approach to quality assurance in laboratory settings.
Application
2-Methylbutane can be used as a reactant to synthesize:
It can also be used as a weakly polar solvent to study the intramolecular charge transfer (ICT) effect and the solvatochromic behavior of the pyrene substituted 1,3,4-oxadiazole derivatives.
- Isoprene by two-stage dehydrogenation process using chromia-alumina catalyst.
- Alkyl aromatic compounds via silver-catalyzed selective C(sp3)–H benzylation reaction in the presence of N-triftosylhydrazones as carbene precursor.
It can also be used as a weakly polar solvent to study the intramolecular charge transfer (ICT) effect and the solvatochromic behavior of the pyrene substituted 1,3,4-oxadiazole derivatives.
Packaging
M-Bottle for Solvents
As a global leader in lab reagents, we are constantly looking for new ways to optimize the safety of our products. The newly developed 4L solvent bottle design features advanced sealing technology that eliminates leaks to make the handling of solvents safer and more convenient than ever before.
See all the new features here!
As a global leader in lab reagents, we are constantly looking for new ways to optimize the safety of our products. The newly developed 4L solvent bottle design features advanced sealing technology that eliminates leaks to make the handling of solvents safer and more convenient than ever before.
See all the new features here!
Analysis Note
Assay (GC): 95% min
Color (APHA): 30 max
Form: Clear liquid
Infrared Spectrum: Conforms to standard
Color (APHA): 30 max
Form: Clear liquid
Infrared Spectrum: Conforms to standard
注意喚起語
Danger
ハザードコード
Hazard Classifications
Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 1 - STOT SE 3
標的臓器
Central nervous system
supp_hazards
保管分類
3 - Flammable liquids
一体何が起きているの?
WGK 2
引火点 (F)
-59.8 °F - closed cup
引火点(°C)
-51 °C - closed cup
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Group 4: Flammable liquids + Special flammables + Hazardous rank I
fsl
Substances Subject to be Indicated Names
ishl_indicated
Substances Subject to be Notified Names
ishl_notified
MX0760-3: + MX0760-1: + MX0760-901:
jan