Wybierz wielkość
11 180,00 zł
11 180,00 zł
Dostępne do wysyłki DZISIAJSzczegóły
Informacje o tej pozycji
Przejdź do
Nazwa produktu
Milligard® 0.5/0.2 µm nominal, Cartridge, pore size 0.5/0.2 μm, cartridge nominal length 40 in. (100 cm)
material
mixed cellulose esters (MCE) membrane
polyester support
polypropylene
silicone seal
reg. compliance
meets EU framework regulation [1935/2004/EC] (all component materials; regarding materials and articles intended to contact food)
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterility
non-sterile
sterilization compatibility
autoclavable compatible
steam-in-place compatible
product line
Milligard®
feature
hydrophilic
manufacturer/tradename
Milligard®
parameter
3.5 bar max. differential pressure (50 psid) at 25 °C
3.5 bar max. inlet pressure (50 psi) at 25 °C
technique(s)
prefiltration: suitable
L
40 in.
W
2.7 in.
cartridge nominal length
40 in. (100 cm)
diam.
7.1 cm (2.8 in.)
filtration area
2.8 m2
impurities
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
gravimetric extractables
≤200 mg/cartridge
matrix
Milligard®
pore size
0.5/0.2 μm nominal pore size
0.5/0.2 μm pore size
input
sample type liquid
cartridge code
Code 7
Quality Level
Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów
1 of 4
Ta pozycja | CW0673S03 | CW0373S03 | CWSS73S03 |
|---|---|---|---|
| pore size 0.5/0.2 μm nominal pore size, 0.5/0.2 μm pore size | pore size - | pore size - | pore size 0.5/0.2 μm nominal pore size, 0.5/0.2 μm pore size |
| technique(s) prefiltration: suitable | technique(s) prefiltration: suitable | technique(s) prefiltration: suitable | technique(s) prefiltration: suitable |
| filtration area 2.8 m2 | filtration area 2.4 m2 | filtration area 2.4 m2 | filtration area 2.1 m2 |
| product line Milligard® | product line Milligard® | product line Milligard® | product line Milligard® |
| matrix Milligard® | matrix Milligard® | matrix Milligard® | matrix Milligard® |
| material mixed cellulose esters (MCE) membrane, polypropylene , polyester support, silicone seal | material mixed cellulose esters (MCE) , polyester support, polypropylene , silicone seal | material mixed cellulose esters (MCE) , polyester support, polypropylene , silicone seal | material mixed cellulose esters (MCE) , polyester support, polypropylene , silicone seal |
Analysis Note
Features and Benefits
General description
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer to the installation and wetting sections of OptiScale®-25 user guide and introduction section of the Mixed cellulose esters Tech Brief
- Storage Statement: Please refer to the Mixed cellulose esters Tech Brief
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Packaging
Preparation Note
10 autoclave cycles or SIP @ 121 °C for 30 min
Legal Information
signalword
Danger
hcodes
Hazard Classifications
Flam. Sol. 1
Klasa składowania
11 - Combustible Solids
wgk
WGK 2
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Powiązane treści
Active Filters
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej