Przejdź do zawartości
Merck

Impact of the grinding process on the quantification of ethyl glucuronide in hair using a validated UPLC-ESI-MS-MS method.

Journal of analytical toxicology (2014-10-03)
Natalie Kummer, Sarah M R Wille, Vincent Di Fazio, Maria Del Mar Ramírez Fernández, Michel Yegles, Willy E E Lambert, Nele Samyn
ABSTRAKT

The Society of Hair Testing (SoHT) has provided cutoffs for the quantification of ethyl glucuronide (EtG) in hair to indicate occasional or chronic/excessive alcohol consumption. Although several sensitive methods have been reported, past proficiency test results show a lack of reproducibility. An ultra-performance liquid chromatographic mass spectrometric method (LLOQ of 10 pg EtG/mg hair) has been validated according to the international guidelines, including the successful participation in five proficiency tests. This method was subsequently used to evaluate the impact of different grinding conditions (cut, weakly or extensively pulverized hair samples) on the final measured EtG concentration. Hair from alcohol consumers (n = 2) and commercially available quality control samples (QCs) (n = 2) was used. For the QCs, extensive pulverization led to a significantly higher amount of measured EtG. In the hair samples obtained from volunteers, cut or weakly pulverized hair resulted in EtG concentrations below the LLOQ, while the mean concentrations of 14 and 40 pg EtG/mg hair were determined after extensive pulverization. Differences in sample preparation could partially explain inter-laboratory variability. As the differences in results can lead to a different interpretation even when applying the SoHT cutoffs, it is of interest to standardize sample preparation techniques in the field of EtG hair testing.

MATERIAŁY
Numer produktu
Marka
Opis produktu

Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Formic acid, ACS reagent, ≥88%
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
USP
Alkohol metylowy, United States Pharmacopeia (USP) Reference Standard
USP
Rozpuszczalnik resztkowy klasy 2 - acetonitryl, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Supelco
Ethyl-β-D-glucuronide, 1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
Ethyl-β-D-glucuronide, 100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Supelco
Methanol, analytical standard
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%