Przejdź do zawartości
Merck
  • Ultrahigh-performance liquid chromatography/tandem mass spectrometry method for evaluating enzyme activity and screening inhibitors of cyclooxygenase-2.

Ultrahigh-performance liquid chromatography/tandem mass spectrometry method for evaluating enzyme activity and screening inhibitors of cyclooxygenase-2.

Rapid communications in mass spectrometry : RCM (2015-01-07)
Hongbin Zhu, Xiaoyu Zhuang, Shu Liu, Zifeng Pi, Fengrui Song, Na Lin, Zhiqiang Liu
ABSTRAKT

Prostaglandin E2 is an important biomarker in many biological systems. The development of sensitive and reliable analytical methods for monitoring PGE2 contents in various samples is of great interest. Here we developed an improved method for evaluating the enzyme activity and screening COX-2 inhibitors using ultrahigh-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) combined with PGE2 derivatization. Girard's reagent-T was used as the derivatization reagent and the reaction conditions were optimized. The established method was performed to screen the COX-2 inhibitors from effective constituents of herbs and detect the concentration of PGE2 in biological tissue samples (liver and kidney). The IC50 values of celecoxib, rofecoxib, sinomenine, bulleyaconitine A, tetrandrine, fangchinoline, berberine hydrochloride and sophocarpidine towards COX-2 were determined. This method improves the quantitative ability for PGE2 , including the linearly dependent coefficient, linearity range and limit of detection. After derivatization, the derivatized PGE2 could be detected in positive ion mode of electrospray ionization (ESI), which improves the detection sensitivity 10-fold compared to that of the direct detection of underivatized PGE2 in negative ESI mode. Besides the positive control, sinomenine (IC50 =113 μM) and bulleyaconitine A (IC50=53 μM) were found to be potent COX-2 inhibitors. All the results indicate that the present derivatization quantification method of PGE2 could be used as the detection method of COX-2 enzyme activity and as the screening method for COX-2 inhibitors.

MATERIAŁY
Numer produktu
Marka
Opis produktu

Sigma-Aldrich
Arachidonic acid, from non-animal source, ≥98.5% (GC)
Millipore
Bifido Selective Supplement B, suitable for microbiology
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Cyclooxygenase 2 human, ≥70% (SDS-PAGE), recombinant, expressed in insect cells, aqueous solution, ≥8000 units/mg protein
Sigma-Aldrich
Arachidonic acid, >95.0% (GC)
Sigma-Aldrich
(−)-Epinephrine
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, ≥97.5%
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, purum, ≥99.0% (TLC)
Sigma-Aldrich
Ammonium bicarbonate, BioUltra, ≥99.5% (T)
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Supelco
5α-Androstan-17β-ol-3-one, VETRANAL®, analytical standard
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Dinoprostone, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
Ammonium bicarbonate, ReagentPlus®, ≥99.0%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
USP
Rozpuszczalnik resztkowy klasy 2 - acetonitryl, United States Pharmacopeia (USP) Reference Standard
USP
Kwas octowy lodowaty, United States Pharmacopeia (USP) Reference Standard
USP
Alkohol metylowy, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Acetic acid-12C2, 99.9 atom % 12C
Sigma-Aldrich
Acetic acid, ≥99.5%, FCC, FG
Sigma-Aldrich
Acetic acid, natural, ≥99.5%, FG
Sigma-Aldrich
Acetic acid, suitable for luminescence, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
Prostaglandin E2, γ-irradiated, powder, BioXtra, suitable for cell culture