Skip to Content
MilliporeSigma
Get up to 22% off for Pi Day until 3/26.Save Now
  • Application of bar adsorptive microextraction (BAμE) for anti-doping control screening of anabolic steroids in urine matrices.

Application of bar adsorptive microextraction (BAμE) for anti-doping control screening of anabolic steroids in urine matrices.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-08-27)
S M Ahmad, C Almeida, N R Neng, J M F Nogueira
ABSTRACT

This study proposes a new analytical methodology for the determination of trace levels of testosterone (T) and epitestosterone (E) in urine matrices using bar adsorptive microextraction combined with liquid desorption followed by high-performance liquid chromatography with diode array detection (BAμE-LD/HPLC-DAD). The comparison of different sorbent coatings (five activated carbons, one styrene-divinylbenzene, two modified pyrrolidone, one ciano and one n-vinylpyrrolidone polymers) through BAμE showed that the latter phase presented much higher selectivity and capacity offering multiple mechanisms of interaction. Assays using this phase were performed on 25mL of water samples spiked at the 8.0μg/L level, yielded average recoveries of 92.1 and 93.4% for T and E, respectively, under optimized experimental conditions; BAμE (n-vinylpyrrolidone): 16h (1000rpm), pH 5.5; LD: acetonitrile, 30min under sonication treatment. From the developed analytical methodology, suitable detection limits were achieved (0.4μg/L) and good linear dynamic ranges (1.4-16.0μg/L) with remarkable determination coefficients (r(2)>0.9978). By using the standard addition methodology, the application of the present analytical approach on urine samples revealed good sensitivity. The proposed method, which operated under the floating sampling technology, proved to be a suitable sorption-based static microextraction alternative for screening T, E and the T/E ratio in urine samples for doping control purposes. The methodology showed to be easy to implement, demonstrating good reproducibility, sensitivity and robustness, allowing the possibility to choose the most selective sorbent coating according to the compounds of interest.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile, ≥99.5%, ACS reagent
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Sodium hydroxide-16O solution, 20 wt. % in H216O, 99.9 atom % 16O
Sigma-Aldrich
Methanol solution, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Acetonitrile, suitable for HPLC-GC, ≥99.8% (GC)
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
USP
Methyl alcohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, suitable for chromatography
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Supelco
Acetonitrile, HPLC grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 300
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for residue analysis, JIS 5000
Sigma-Aldrich
Acetonitrile, SAJ first grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 1000
Sigma-Aldrich
Sodium chloride solution, 5 M in H2O, BioReagent, Molecular Biology, suitable for cell culture
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Supelco
Sodium chloride, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%