Skip to Content
MilliporeSigma
  • Rapid, sensitive and selective HPLC-MS/MS method for the quantification of topically applied besifloxacin in rabbit plasma and ocular tissues: Application to a pharmacokinetic study.

Rapid, sensitive and selective HPLC-MS/MS method for the quantification of topically applied besifloxacin in rabbit plasma and ocular tissues: Application to a pharmacokinetic study.

Journal of pharmaceutical and biomedical analysis (2015-09-05)
Xiao-Fei Gu, Bai-Yang Mao, Min Xia, Yang Yang, Jia-Li Zhang, Da-Song Yang, Wei-Xin Wu, Ying-Xiang Du, Bin Di, Meng-Xiang Su
ABSTRACT

Besifloxacin is a fourth-generation broad-spectrum fluoroquinolone registered for the topical treatment of bacterial conjunctivitis. In this study, a rapid, sensitive and selective liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for quantification of besifloxacin in rabbit plasma and ocular tissues using nateglinide as the internal standard (IS). The analyte and IS were separated on a Sepax GP-Phenyl column by isocratic elution with methanol-acetonitrile-5 mM ammonium formate-formic acid (29:55:16:0.1, v/v/v/v) as the mobile phase at a flow rate of 1.2 mL/min, and the total run time was 3.0 min. An electrospray ionization (ESI) source was applied and operated in the positive ion mode; multiple reaction monitoring (MRM) mode was used for quantification, and the monitored transitions were 394.2→377.1 for besifloxacin and m/z 318.3→166.1 for the IS. The calibration curve was linear over the range of 0.103-206 ng/mL for plasma and 2.06-2060 ng/mL for tears, aqueous humor, conjunctiva and cornea with correlation coefficient (r) greater than 0.99. The lower limit of quantification (LLOQ) for besifloxacin was 0.103 ng/mL for plasma and 2.06 ng/mL for other ocular tissues with good accuracy and precision. Intra- and inter-batch precision were both lower than 15% and accuracy ranged from 85% to 115% at all QC levels. The method was successfully applied to the pharmacokinetic study of besifloxacin in rabbit plasma and ocular tissues after single and multiple topical administrations.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrile, SAJ first grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 300
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 1000
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Formic acid, JIS special grade, ≥98.0%
Sigma-Aldrich
Acetonitrile, suitable for chromatography
Sigma-Aldrich
Acetonitrile, suitable for residue analysis, JIS 5000
Supelco
Acetonitrile, HPLC grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Supelco
Ammonium formate solution, 10 mM in H2O, suitable for HPLC
Sigma-Aldrich
Methanol solution, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Sigma-Aldrich
Acetonitrile, ≥99.5%, ACS reagent
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Ultrapure Acetonitrile
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Formic acid, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
Formic acid, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
Formic acid, ACS reagent, ≥88%
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Supelco
Methanol solution, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Methanol, suitable for HPLC