Skip to Content
MilliporeSigma

Skip To

D901

Decane

ReagentPlus®, ≥99%

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
100 mL
Check Cart for Availability
$66.40
500 mL
Check Cart for Availability
$193.00

About This Item

Linear Formula:
CH3(CH2)8CH3
CAS Number:
Molecular Weight:
142.28
UNSPSC Code:
12352001
NACRES:
NA.06
PubChem Substance ID:
EC Number:
204-686-4
Beilstein/REAXYS Number:
1696981
MDL number:
Assay:
≥99%
Technique(s):
gas chromatography (GC): suitable
Bp:
174 °C (lit.)
Vapor pressure:
1 mmHg ( 16.5 °C), 3.77 mmHg ( 37.7 °C)

$66.40


Check Cart for Availability

​
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


vapor density

4.9 (vs air)

Quality Segment

vapor pressure

1 mmHg ( 16.5 °C), 3.77 mmHg ( 37.7 °C)

product line

ReagentPlus®

assay

≥99%

form

liquid

autoignition temp.

410 °F

expl. lim.

2.6 %

technique(s)

gas chromatography (GC): suitable

refractive index

n20/D 1.411 (lit.)

bp

174 °C (lit.)

mp

−30 °C (lit.)

density

0.73 g/mL at 25 °C (lit.)

SMILES string

CCCCCCCCCC

InChI

1S/C10H22/c1-3-5-7-9-10-8-6-4-2/h3-10H2,1-2H3

InChI key

DIOQZVSQGTUSAI-UHFFFAOYSA-N

General description

Decane (n-Decane), an aliphatic hydrocarbon, is a reference fuel. Its oxidation over a range of temperature has been studied. Its crystal structure has been investigated at 150K. The cracking of decane can be performed using electrohydrodynamic atomization system (EHDA).

Application

Internal standard in the GC analysis of oxalic, malonic, and succinic acids in biological materials.
Decane has been used as a solvent in the preparation of high alkane phase emulsified suspensions (HAPES). It may also be used as a solvent to suspend the CdSe/ZnS nanocrystals during absorbance measurement.

Legal Information

ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
3054030570DX0030
description

ReagentPlus®, ≥99%

description

analytical standard

description

≥95%

description

-

assay

≥99%

assay

≥99.8% (GC)

assay

≥95%

assay

≥98% (GC)

technique(s)

gas chromatography (GC): suitable

technique(s)

gas chromatography (GC): suitable, HPLC: suitable

technique(s)

-

technique(s)

-

Quality Level

200

Quality Level

100

Quality Level

100

Quality Level

200

form

liquid

form

-

form

liquid

form

liquid

vapor pressure

3.77 mmHg ( 37.7 °C), 1 mmHg ( 16.5 °C)

vapor pressure

1 mmHg ( 16.5 °C), 3.77 mmHg ( 37.7 °C)

vapor pressure

1 mmHg ( 16.5 °C), 3.77 mmHg ( 37.7 °C)

vapor pressure

1 hPa ( 16 °C)

vapor density

4.9 (vs air)

vapor density

4.9 (vs air)

vapor density

4.9 (vs air)

vapor density

-


Still not finding the right product?

Explore all of our products under Decane


pictograms

FlameHealth hazard

signalword

Danger

hcodes

Hazard Classifications

Asp. Tox. 1 - Flam. Liq. 3

supp_hazards

Storage Class

3 - Flammable liquids

wgk

WGK 1

flash_point_f

114.8 °F - closed cup

flash_point_c

46 °C - closed cup



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value