Fortfahren mit
Größe auswählen
| Größe/SKU | Verfügbarkeit | Preis |
|---|---|---|
20 mL | Warenkorb auf Verfügbarkeit prüfen | CHF 4'620.00 |
Über diesen Artikel
CHF 4'620.00
Quality Segment
material
316 stainless steel cannula, polycarbonate syringe (fluid contact layer), polyester body, silicone septum (platinum-cured), silicone syringe (medical fluid contact layer; platinum cured silicone), silicone tubing
agency
ISO 10993-5 (all component materials), USP 87 Cytotoxicity Elution Test (In Vitro), according to ISO 11131 (sterilization), according to ISO 146441, meets the criteria for Biological Reactivity Testing: can be any one or a combination of the following test methods USP<88> Systemic Injection Test (In Vivo)
sterility
sterile; β-irradiated
product line
NovaSeptum® GO
feature
autoclavable
parameter
-80-121 °C temp. range (-112-250 °F), 0.50 bar max. pressure (7.25 psi)
impurities
<2.15 EU/device bacterial endotoxins (LAL test)
fitting
female Luer-Lok® outlet, male Luer-Lok® outlet
application(s)
cell therapy
gene therapy
life science and biopharma
mAb
ophthalmics
parenterals
pathogen testing
pharma/biopharma processes
pyrogen testing
sterile sampling
sterility testing
viral therapy
storage temp.
10-30°C
General description
Application
Packaging
Preparation Note
Aqueous extraction contains < 2.15 EU per device as determined using the Limulus Amebocyte Lysate (LAL) test.
Other Notes
- Septum: Platinum-cured silicone
- Body: Polyester
- Cannula: ASTM® 316 L Stainless steel
- Fluid contact layer (syringe): Polycarbonate, platinum-cured silicone, medical silicone fluid
- Tubing: Silicone
- Outlet Tubing: Female and male Luer-Lok®
Legal Information
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| description 20mL | description 5x5mL | description 5x20mL | description 5mL |
| fitting male Luer-Lok® outlet, female Luer-Lok® outlet | fitting female Luer-Lok® outlet, male Luer-Lok® outlet | fitting male Luer-Lok® outlet, female Luer-Lok® outlet | fitting male Luer-Lok® outlet, female Luer-Lok® outlet |
| product line NovaSeptum® GO | product line NovaSeptum® GO | product line NovaSeptum® GO | product line NovaSeptum® GO |
| agency according to ISO 11131 (sterilization), meets the criteria for Biological Reactivity Testing: can be any one or a combination of the following test methods USP<88> Systemic Injection Test (In Vivo), according to ISO 146441, USP 87 Cytotoxicity Elution Test (In Vitro), ISO 10993-5 (all component materials) | agency meets the criteria for Biological Reactivity Testing: can be any one or a combination of the following test methods USP<88> Systemic Injection Test (In Vivo), according to ISO 146441, USP 87 Cytotoxicity Elution Test (In Vitro), ISO 10993-5 (all component materials), according to ISO 11137 (sterilization) | agency according to ISO 146441, meets the criteria for Biological Reactivity Testing: can be any one or a combination of the following test methods USP<88> Systemic Injection Test (In Vivo), according to ISO 11137 (sterilization), ISO 10993-5 (all component materials), USP 87 Cytotoxicity Elution Test (In Vitro) | agency according to ISO 11131 (sterilization), according to ISO 146441, ISO 10993-5 (all components materials), meets the criteria for Biological Reactivity Testing: can be any one or a combination of the following test methods USP <88> Systemic Injection Test (In Vivo), USP 87 Cytotoxicity Elution Test (In Vitro) |
| material 316 stainless steel cannula, polyester body, polycarbonate syringe (fluid contact layer), silicone septum (platinum-cured), silicone syringe (medical fluid contact layer; platinum cured silicone), silicone tubing | material polyester body, 316 stainless steel cannula, polycarbonate syringe (fluid contact layer), PureFlex™ polyethylene bag (Drainage bag), silicone septum (platinum-cured), silicone tubing, silicone syringe (medical fluid contact layer; platinum cured silicone) | material 316 stainless steel cannula, PureFlex™ polyethylene bag (Drainage bag), polyester body, silicone syringe (medical fluid contact layer; platinum cured silicone), silicone septum (platinum-cured), polycarbonate syringe (fluid contact layer), silicone tubing | material 316 stainless steel cannula, silicone tubing, silicone septum (platinum-cured), polycarbonate syringe (fluid contact layer), silicone syringe (medical fluid contact layer; platinum cured silicone), polyester body |
| storage temp. 10-30°C | storage temp. 10-30°C | storage temp. 10-30°C | storage temp. 10-30°C |
| application(s) cell therapy | application(s) cell therapy | application(s) cell therapy | application(s) cell therapy |
Still not finding the right product?
Explore all of our products under NovaSeptum® GO Sampling System; Accurate Volume Application
Bleiben Sie mit dem Emprove®-Programm GMP-konform
Beschleunigen Sie die Qualifizierung, halten Sie die Vorschriften ein und sparen Sie Zeit mit Emprove® Dossiers.
Hinweis: Sie werden zu EmproveSuite.com weitergeleitet. Ihr Benutzername und Passwort sind von SigmaAldrich.com getrennt und können abweichen.
Registrieren Sie sich kostenlos und erhalten Sie innerhalb weniger Minuten Zugang zu Emprove® Dossiers. Aktualisieren Sie Ihr Abonnement, um erweiterte und angepasste Inhalte in der Emprove® Suite freizuschalten.
Sie finden nicht, was Sie suchen? Besuchen Sie die Emprove® Programm-Hilfeseite.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Können Sie Ihr Produkt oder Ihre Lot-/Chargennummer nicht finden?
So finden Sie die Produktnummer
Produktnummern werden bei der Anzeige auf der Website mit Packungsgrößen/-menge kombiniert (Beispiel: T1503-25G). Bitte stellen Sie sicher NUR die Produktnummer in das Feld Produktnummer eingeben (Beispiel: T1503).
Beispiel:
Weitere Beispiele:
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
eingeben als 1.000309185)
Haben Sie Probleme? Sie können sich jederzeit an uns wenden Technischer Dienst zur Unterstützung