Sélectionner une taille de conditionnement
A propos de cet article
Nom du produit
Millipore Express® SHF, Capsule Opticap® XLT, Chemistry: Hydrophilic Polyethersulfone (PES) Inlet: 1 in. Hose Barb Outlet: 1 in. Hose Barb T-line with 3/4 in. Gauge Port Max Operating Pressure: 80psi @ 25 °C
Quality Segment
material
polyester support, polypropylene housing, polypropylene vent cap, silicone seal, polyethersulfone membrane, silicone O-ring
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterility
non-sterile
sterilization compatibility
autoclavable compatible
gamma compatible
x-ray compatible
product line
Opticap® XLT
feature
hydrophilic
manufacturer/tradename
Millipore Express®
parameter
1 bar max. differential pressure (15 psi) at 80 °C, 1.0 bar max. inlet pressure (15 psi) at 80 °C, 2.8 bar max. inlet pressure (40 psi) at 60 °C, 5.5 bar max. differential pressure (80 psi) at 25 °C, 5.5 bar max. inlet pressure (80 psi) at 25 °C, 6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; Intermittent), 6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
technique(s)
sterile filtration: suitable
W
7.8 in.
cartridge nominal length
30 in. (75 cm)
device L
87.1 cm (34.3 in.)
filter diam.
10.7 cm (4.2 in.)
filter filtration area
1.7 m2 (18.3 ft2)
impurities
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
matrix
Millipore Express® SHF
pore size
0.2 μm pore size
bubble point
≥4000 mbar (58 psig), air with water at 23 °C
fitting
25 mm (1 in.) inlet hose barb, 25 mm (1 in.) outlet hose barb
General description
Packaging
Preparation Note
3 autoclave cycles of 60 min at 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
Analysis Note
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Legal Information
Still not finding the right product?
Explore all of our products under Millipore Express® SHF, Capsule Opticap® XLT
Restez en conformité avec les BPF grâce au programme Emprove®.
Accélérer la qualification, maintenir la conformité et gagner du temps avec Emprove® Dossiers.
Note: you will be brought to EmproveSuite.com. Your username and password are separate from SigmaAldrich.com and may differ.
Inscrivez-vous gratuitement et accédez à Emprove® Dossiers en quelques minutes. Mettez votre abonnement à niveau pour débloquer un contenu avancé et personnalisé dans la Emprove® Suite
Vous ne trouvez pas ce que vous cherchez ? Visitez la page d'aide du programme Emprove®..
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Vous avez des difficultés à trouver la référence de votre produit ou son numéro de lot ?
Comment trouver le numéro de produit
Les références de produits sont combinées avec des tailles de conditionnement/quantités lorsqu'elles figurent sur le site Internet (exemple : T1503-25G). Assurez-vous de ne saisir QUE la référence du produit dans le champ Référence produit (exemple: T1503).
Exemple :
Autres exemples :
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
entrer en tant que 1.000309185)
Vous rencontrez des problèmes ? N'hésitez pas à contacter Service technique pour obtenir une assistance