Accéder au contenu
Merck

F6428

Réactif pour glycérol à l′état libre

used for quantitative enzymatic determination of glycerol

Se connecter pour consulter les tarifs organisationnels et contractuels.

Sélectionner une taille de conditionnement

40 ML

221,00 €

221,00 €


Vérifier la disponibilité des articles du panier

Demander une commande groupée

A propos de cet article

MDL number:
UNSPSC Code:
12161503
NACRES:
NA.25

Passer à

Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider

Nom du produit

Réactif pour glycérol à l′état libre, used for quantitative enzymatic determination of glycerol

InChI

1S/C3H8O3/c4-1-3(6)2-5/h3-6H,1-2H2

InChI key

PEDCQBHIVMGVHV-UHFFFAOYSA-N

SMILES string

C(C(CO)O)O

form

solid

usage

40 mL sufficient for 50 reactions

color

white to off-white

functional group

hydroxyl

relevant disease(s)

obesity

storage temp.

2-8°C

Quality Level

Comparer avec des articles similaires

Voir la comparaison complète

Montrer les différences

1 of 4

Cet article
G7793FG0100374813
functional group

hydroxyl

functional group

-

functional group

-

functional group

-

form

solid

form

-

form

-

form

liquid

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

100

color

white to off-white

color

-

color

-

color

-

usage

40 mL sufficient for 50 reactions

usage

-

usage

 kit sufficient for 1000 reactions

usage

-

Application

Le réactif pour glycérol à l'état libre facilite la détermination enzymatique quantitative des taux de glycérol dans le sérum ou le plasma. Il peut aussi servir à mesurer la libération de glycérol par lipolyse dans les tissus adipeux.[1][2]

Biochem/physiol Actions

Le glycérol subit une phosphorylation sous l'effet de l'action enzymatique de la glycérol kinase (GK), utilisant de l'adénosine-5′-triphosphate (ATP) pour produire du glycérol-1-phosphate (G-1-P) et de l'adénosine-5′-diphosphate (ADP). Le glycérol-1-phosphate (G-1-P) est ensuite oxydé par la glycérol phosphate oxydase (GPO) pour donner du dihydroxyacétone phosphate (DAP) et du peroxyde d'hydrogène (H2O2). Ce processus fait intervenir la peroxydase (POD), qui catalyse le couplage du peroxyde d'hydrogène (H2O2) avec la 4-aminoantipyrine (4-AAP) et la N-éthyl-N-(3-sulfopropyl) m-anisidine de sodium (ESPA) pour produire de la quinoneimine, un colorant présentant un pic d'absorbance à 540 nm.La hausse de l'absorbance observée à 540 nm est directement corrélée à la concentration du glycérol libre présent dans l'échantillon. Cette méthode permet de quantifier de manière fiable les taux de glycérol libre et d'analyser précisément les échantillons biochimiques.
Le réactif pour glycérol à l′état libre utilise des réactions à enzymes couplées pour produire une augmentation d′absorbance à 540 nm directement proportionnelle à la concentration en glycérol.

Features and Benefits

  • Processus simplifié : rationalisez le déroulement de vos procédures grâce à un réactif unique, offrant un temps de réaction rapide de 5 minutes.
  • Conception conviviale : plus besoin de peser ou de mélanger de multiples réactifs, pour une plus grande simplicité d'utilisation et une plus grande efficacité.

General description

Le réactif pour glycérol à l'état libre offre une méthode de mesure précise des taux de glycérol endogène libre par le biais de réactions enzymatiques couplées, ce qui permet de s'affranchir de l'hydrolyse initiale par la lipase. Contrairement aux triglycérides, qui sont généralement liés à des protéines et transportés par le plasma, le glycérol à l'état libre circule de manière indépendante. Cette approche innovante est basée sur une hydrolyse enzymatique ou alcaline des triglycérides, libérant du glycérol et des acides gras libres pour une mesure exacte.

Le kit de dosage des triglycérides sériques (référence TR0100) offre une solution complète pour évaluer le glycérol, les vrais triglycérides et les triglycérides totaux dans les échantillons de sérum et de plasma. Via une hydrolyse enzymatique par la lipase, les triglycérides sont convertis en acides gras libres et en glycérol et peuvent ainsi être quantifiés précisément par la référence F6428 grâce à des réactions enzymatiques couplées.

Contrairement à de nombreux réactifs de dosage des triglycérides du commerce, cette méthode permet de distinguer le glycérol endogène du glycérol issu de l'hydrolyse des glycérides par la lipase. Grâce à cette technologie avancée, les chercheurs peuvent analyser en toute confiance les taux de glycérol avec une exactitude et une fiabilité exceptionnelles.

Other Notes

En plus des kits, les réactifs individuels et l'étalon de glycérol sont disponibles séparément pour réaliser un plus petit nombre de réactions.
Pour de plus amples informations sur notre gamme de Produits biochimiques, merci de compléter ce formulaire.

signalword

Danger

Hazard Classifications

Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Eye Dam. 1 - Skin Irrit. 2

Classe de stockage

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Geonho Kim et al.
Journal of insect physiology, 106(Pt 1), 13-19 (2017-05-20)
Acetic acid is a fermentation product of many microorganisms, including some that inhabit the food and guts of Drosophila. Here, we investigated the effect of dietary acetic acid on oviposition and larval performance of Drosophila. At all concentrations tested (0.34-3.4%)
GIP receptor deletion in mice confers resistance to high-fat diet-induced obesity via alterations in energy expenditure and adipose tissue lipid metabolism
Boer GA, et al.
American Journal of Physiology. Endocrinology and Metabolism, 320, E835-E845 (2021)
Adipocyte Gs but not Gi signaling regulates whole-body glucose homeostasis
Caron A, et al.
Molecular Metabolism, 27, 11-21 (2019)
Floriana Rotondo et al.
PeerJ, 4, e2725-e2725 (2016-12-06)
White adipose tissue (WAT) is a complex, diffuse, multifunctional organ which contains adipocytes, and a large proportion of fat, but also other cell types, active in defense, regeneration and signalling functions. Studies with adipocytes often require their isolation from WAT
Claire Regazzetti et al.
Diabetes, 58(1), 95-103 (2008-11-06)
Obesity is characterized by an overgrowth of adipose tissue that leads to the formation of hypoxic areas within this tissue. We investigated whether this phenomenon could be responsible for insulin resistance by studying the effect of hypoxia on the insulin

Articles

Lipid Induced Insulin Resistance

Contenu apparenté

Questions

1–5 sur 5 questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 réponse
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Utile ?

  2. I would like to measure the concentration of free glycerol in the culture supernatant of adipocytes using this reagent with a plate reader instead of a cuvette. What are recommended sample and reagent volumes for a plate reader? Have you ever tested?

    1 réponse
    1. This product has not been tested for use with a well plate format. The product instructions call for a total volume of 830 µL, where 10 µL each of water, glycerol standard, and sample are added to cuvettes containing 800 µL of Free Glycerol Reagent. Most 96-well plates have a working volume of 100-300 µL, so the volume of each component would need to be scaled accordingly. Adding 3 µL each of water, glycerol standard, and sample to wells containing 240 µL of Free Glycerol Reagent would result in the same concentrations with a total volume of 249 µL. Regardless, the functionality of a plate reader in this application cannot be guaranteed and would need to be assessed independently.

      Utile ?

  3. I have an old version of this product (6428) - just one bottle not a kit. I need to reconstitute this but can't find instructions. Can you let me know what to reconstitute in and how much? Thank you!

    1 réponse
    1. There are no specific instructions for 6428. F6428 is one bottle of reagent as well. The user guide of F6428 may serve as a reference. A typical reconstitution procedure of F6428 is: Reconstitute the Free Glycerol Reagent with 40 ml of water. After addition of water, stopper the vials, and immediately mix several times by inversion. DO NOT SHAKE. Protect the reagent from light by storing in amber bottles. Please check page 2 of the user guide here:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/352/968/f6428bul.pdf

      Utile ?

  4. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 réponse
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Utile ?

  5. Could you kindly send me a package insert and a manual application for determination on automated clinical systems? Many thanks.

    1 réponse
    1. The Free Glycerol Reagent is for R&D use only, not for in vitro diagnostic use, drug, household, or other uses. Please consult the Material Safety Data Sheet for information regarding hazards and safe handling practices.

      Utile ?

Évaluations

Aucune valeur de notation

Filtres actifs

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique