Nome del prodotto
Millipore Express® SHR, Opticap® XL Capsule, Opticap® XL 3, sterile, inlet connection diam. 9/16 in., cartridge nominal length 3 in. (7.5 cm)
Materiali
polyester support
polyethersulfone
polypropylene
polypropylene housing
polypropylene vent cap
silicone seal
Livello qualitativo
Conformità normativa
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
Sterilità
irradiated
sterile
Nome Commerciale
Opticap® XL 3
Caratteristiche
hydrophilic
Produttore/marchio commerciale
Millipore Express®
Parametri
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
tecniche
sterile filtration: suitable
Lunghezza
17.3 cm (6.8 in.)
Lunghezza nominale della cartuccia
3 in. (7.5 cm)
Diametro
10.7 cm (4.2 in.)
Superficie filtrante
0.17 m2
Diam. connessione ingresso
9/16 in.
Amp. ingresso/ uscita
17.3 cm (6.8 in.)
Diam. connessione uscita
9/16 in.
Impurezze
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matrice
Millipore Express® SHR
Dimensione pori
0.1 μm
Punto di bolla
≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water at 23 °C
Raccordi
1/4 in. drain/vent hose barb (with double O-ring Seal)
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)
1 of 4
Questo articolo | KVEPS03TT3 | KVEPA03HH3 | KVEPA03TH3 |
|---|---|---|---|
| pore size 0.1 μm | pore size 0.1 μm | pore size 0.1 μm | pore size 0.1 μm |
| filtration area 0.17 m2 | filtration area 0.17 m2 | filtration area 0.16 m2 | filtration area 0.16 m2 |
| product line Opticap® XL 3 | product line Opticap® XL 3 | product line Opticap® XL 3 | product line Opticap® XL 3 |
| technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable |
| material polyester support, polypropylene , polypropylene vent cap, polyethersulfone , silicone seal, polypropylene housing | material polyester support, polyethersulfone , polypropylene , polypropylene housing, polypropylene vent cap, silicone seal | material polyethersulfone , polypropylene , polypropylene housing, polypropylene support, polypropylene vent cap, silicone seal | material polyethersulfone , polypropylene , polypropylene housing, polypropylene support, polypropylene vent cap, silicone seal |
| manufacturer/tradename Millipore Express® | manufacturer/tradename Millipore Express® | manufacturer/tradename Millipore Express® | manufacturer/tradename Millipore Express® |
Descrizione generale
Confezionamento
Nota sulla preparazione
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Risultati analitici
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 3.5 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Altre note
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Note legali
Esclusione di responsabilità
Mantenere la conformità alle GMP utilizzando il programma Emprove®.
Accelerate la qualificazione, mantenete la conformità e risparmiate tempo con Emprove® Dossiers.
Nota: verrete portati su EmproveSuite.com. Il vostro nome utente e la vostra password sono separati da SigmaAldrich.com e possono essere diversi.
Registrati gratuitamente e accedi a Emprove® Dossiers in pochi minuti. Aggiornate il vostro piano di abbonamento per sbloccare contenuti avanzati e personalizzati nella Emprove® Suite.
Non trovate quello che state cercando? Visitate la pagina di aiuto del programma Emprove®..
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Filtri attivi
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica